Realization of the Pascal based on Argon using a Fabry-P\'erot refractometer

Based on a recent experimental determination of the static polarizability and a first-principles calculation of the frequency-dependent dipole polarizability of argon, this work presents, by use of a Fabry-P\'erot refractometer operated at 1550 nm, a realization of the SI unit of pressure, the pascal, for pressures up to 100 kPa, with an uncertainty of [(0.98 mPa)$^2 + (5.8 \times 10^{-6} P)^2 + (26\times10^{-12}P^2)^2]^{1/2}$. The work also presents a value of the molar polarizability of N$_2$ at 1550 nm of 4.396572(26)$\times 10^{-6}$m$^{3}$/mol, which agrees well with previously determined ones in the literature.

physics.optics

Sub-Doppler optical-optical double-resonance spectroscopy using a cavity-enhanced frequency comb probe

Accurate parameters of molecular hot-band transitions, i.e., those starting from vibrationally excited levels, are needed to accurately model high-temperature spectra in astrophysics and combustion, yet laboratory spectra measured at high temperatures are often unresolved and difficult to assign. Optical-optical double-resonance (OODR) spectroscopy allows the measurement and assignment of individual hot-band transitions from selectively pumped energy levels without the need to heat the sample. However, previous demonstrations lacked either sufficient resolution, spectral coverage, absorption sensitivity, or frequency accuracy. Here we demonstrate OODR spectroscopy using a cavity-enhanced frequency comb probe that combines all these advantages. We detect and assign sub-Doppler transitions in the spectral range of the 3${\nu}$${_3}$${\leftarrow}$${\nu}$${_3}$ resonance of methane with frequency precision and sensitivity more than an order of magnitude better than before. This technique will provide high-accuracy data about excited states of a wide range of molecules that is urgently needed for theoretical modeling of high-temperature data and cannot be obtained using other methods.

physics.chem-ph

Sub-Doppler Double-Resonance Spectroscopy of Methane Using a Frequency Comb Probe

We report the measurement of sub-Doppler double-resonance transitions in methane using a 3.3 $\mu$m continuous wave optical parametric oscillator to pump transitions in the fundamental $\nu_3$ band and a 1.67 $\mu$m frequency comb to probe ladder-type transitions in the 3$\nu_3$ band over 200 cm$^{-1}$ of bandwidth. We detected 36 ladder-type resonances for 9 pumped transitions with average center frequency accuracy of 1.7 MHz, limited by the pump frequency stability. The lines are assigned using the TheoReTS line list, and the intensity ratios for different relative pump/probe polarizations. This method provides accurate assignment of highly excited energy levels that cannot be done using high temperature spectra.

physics.chem-ph

Gas modulation refractometry (GAMOR) - On its ability to eliminate the influence of drifts

Gas modulation refractometry (GAMOR) is a technique based on a dual-Fabry-Perot (FP) cavity (DFPC) for assessment of gas refractivity, density, and pressure that can alleviate significant limitations of conventional refractometry systems, predominantly those related to drifts. Repeated assessments of the beat frequency when the measurement cavity is evacuated provide conditions under which the methodology is immune to the linear parts of the drifts in the system, both those from length changes of the cavities and those from gas leaks and outgassing. This implies that the technique is solely influenced by the non-linear parts of the drifts. This work provides a description of the principle behind the GAMOR methodology and explicates the background to its unique property. Based on simple models of the drifts of the temperature in the cavity spacer and the residual gas in the reference cavity, this work predicts that a GAMOR system, when used for assessment of refractivity, can sustain significant temperature drifts and leakage rates without being affected by noticeable errors or uncertainties. The cavity spacer can be exposed to temperature fluctuations of 100 mK over 103 s, and the reference cavity can have a leakage that fills it up with gas on a timescale of days, without providing errors or uncertainties in the assessment of refractivity that are 3 x 10^(-12), which, for N2, corresponds to 0.01 ppm (parts per million) of the value under atmospheric pressure conditions, and thereby 1 mPa. Since well-designed systems often have temperature fluctuations and leakage rates that are smaller than these, it is concluded that there will, in practice, not be any appreciable influence from cavity length drifts, gas leaks, and outgassing in the GAMOR methodology.

physics.ins-det

Gas equilibration gas modulation refractometry (GEq-GAMOR) for assessment of pressure with sub-ppm precision

A novel realization of Gas Modulation Refractometry (GAMOR) that outperforms the original realization [Single Cavity Modulated GAMOR (SCM-GAMOR)], is presented. The reference measurements are carried out by equalizing the pressures in the two cavities. By this, the time it takes to reach adequate conditions for the reference measurements has been reduced. This implies that a larger fraction of the measurement cycle can be devoted to data acquisition, which reduces white noise and improves on short-term characteristics. The presented realization also encompasses a new cavity design with improved temperature stabilization and assessment. This has contributed to an improved long-term characteristics. The system was characterized with respect to a dead weight piston gauge. For short integration times (up to 10 min) it can provide a response that exceeds that of the original SCM-GAMOR system by a factor of two. For longer integration times, and up to 18 hours, the system shows, at 4303 Pa, an integration time independent Allan deviation of 1 mPa (corresponding to a precision defined as twice the Allan deviation, of 0.5 ppm). This implies that the novel system shows a significant improvement with respect to the original realization for all integration times (by a factor of 8 for an integration time of 18 hours). When used for low pressures, it can provide a precision in the sub-mPa region; for the case with an evacuated measurement cavity, the system provided, up to ca. 40 measurement cycles (ca. 1.5 hours), a white-noise limited noise of 0.7 mPa sqrt(cycle), and minimum Allan deviation of 0.15 mPa. Furthermore, over the pressure range investigated, i.e. in the 2.8 - 10.1 kPa range, it shows, with respect to a dead weight piston gauge, a purely linear response. This implies that the system can be used for transfer of calibration over large pressure ranges with exceptional low uncertainty.

physics.ins-det

Model for molecular absorption spectroscopy in the 1-100 Torr range in the presence of vibrational depletion - Applied to $\text{CH}_4$ in $\text{N}_2$ and dry air

When molecules whose collision induced vibrational decay rates are small are probed by molecular absorption spectroscopic (MAS) techniques the absorption signal can, under certain conditions, be reduced and distorted. The reason has been attributed to the fact that a substantial fraction of the molecules in the interaction region will reside in excited vibrational states, which leads to a depletion of the vibrational ground state. One type of molecule in which this can take place is methane. A model for this phenomenon, based on $\text{CH}_4$ in trace concentrations in either $\text{N}_2$ or dry air in a cylindrical gas cell, detected by mid-infrared light in the 1 - 100 Torr pressure range, is presented. Due to a fast collisional coupling between various rotational states and velocity groups we suggest that depletion in MAS can be modeled adequately by a simple three-level system to which the transport of molecules in the system is coupled as diffusion according to Fick's law, applied to each level individually. The model is verified in a separate work [Hausmaninger T et al., J Quant Spectrosc Radiat Tr. 2017;205:59-70] with good agreement. It predicts that depletion has a strong pressure dependence in the 1 - 30 Torr range, that it is significantly more pronounced in $\text{N}_2$ than in air, and that considerable degrees of depletion can be obtained for mW powers of light (> 10% for powers > 20 mW). The findings indicate that, unless precautions are taken, depletion can adversely affect quantitative assessments performed by MAS. Means of how to reduce depletion are given.

physics.atom-ph

High resolution ultra-sensitive trace gas detection by use of cavity-position-modulated sub-Doppler NICE-OHMS - Application to detection of acetylene in human breath

A sensitive high resolution sub-Doppler detecting spectrometer, based on noise-immune cavity-enhanced optical heterodyne molecular spectrometry (NICE-OHMS), for trace gas detection of species whose transitions have severe spectral overlap with abundant concomitant species is presented. It is designed around a NICE-OHMS instrumentation utilizing balanced detection that provides shot-noise limited Doppler-broadened detection. By synchronous dithering the positions of the two cavity mirrors, the effect of residual etalons between the cavity and other surface in the system could be reduced. An Allan deviation of the absorption coefficient of coefficient of $2.2 \times 10^{-13}$ $\text{cm}^{-1}$ at 60 s, which, for the targeted transition in $\text{C}_{2}\text{H}_{2}$, corresponds to a $3\sigma$ detection sensitivity of 130 ppt, is demonstrated. It is shown that despite significant spectral interference from $\text{CO}_{2}$ at the targeted transition, which precludes Db detection of $\text{C}_{2}\text{H}_{2}$, acetylene could be detected in exhaled breath of healthy smokers.

physics.ins-det

Broadband calibration-free cavity-enhanced complex refractive index spectroscopy using a frequency comb

We present broadband cavity-enhanced complex refractive index spectroscopy (CE-CRIS), a technique for calibration-free determination of the complex refractive index of entire molecular bands via direct measurement of transmission modes of a Fabry-Perot cavity filled with the sample. The measurement of the cavity transmission spectrum is done using an optical frequency comb and a mechanical Fourier transform spectrometer with sub-nominal resolution. Molecular absorption and dispersion spectra (corresponding to the imaginary and real parts of the refractive index) are obtained from the cavity mode broadening and shift retrieved from fits of Lorentzian profiles to the individual cavity modes. This method is calibration-free because the mode broadening and shift are independent of the cavity parameters such as the length and mirror reflectivity. In this first demonstration of broadband CE-CRIS we measure simultaneously the absorption and dispersion spectra of three combination bands of CO2 in the range between 1525 nm and 1620 nm and achieve good agreement with theoretical models. This opens up for precision spectroscopy of the complex refractive index of several molecular bands simultaneously.

physics.optics

Sensitive and broadband measurement of dispersion in a cavity using a Fourier transform spectrometer with kHz resolution

Optical cavities provide high sensitivity to dispersion since their resonance frequencies depend on the index of refraction. We present a direct, broadband, and accurate measurement of the modes of a high finesse cavity using an optical frequency comb and a mechanical Fourier transform spectrometer with a kHz-level resolution. We characterize 16000 cavity modes spanning 16 THz of bandwidth in terms of center frequency, linewidth, and amplitude. We retrieve the group delay dispersion of the cavity mirror coatings and pure N${_2}$ with 0.1 fs${^2}$ precision and 1 fs${^2}$ accuracy, as well as the refractivity of the 3{\nu}1+{\nu}3 absorption band of CO${_2}$ with 5 x 10${^{-12}}$ precision. This opens up for broadband refractive index metrology and calibration-free spectroscopy of entire molecular bands.

physics.ins-det

Fast Switching Dual Fabry-Perot-Cavity-based Optical Refractometry for Assessment of Gas Refractivity and Density - Estimates of Its Precision, Accuracy, and Temperature Dependence

Dual Fabry-Perot-Cavity-based Optical Refractometry (DFCB-OR) have been shown to have excellent potential for characterization of gases, in particular their refractivity and density. However, its performance has in practice been found to be limited by drifts. To remedy this, drift-free DFPC-OR (DF-DFCB-OR) has recently been proposed. Suggested methodologies for realization of a specific type of DF-DFCB-OR, termed Fast Switching DFCB-OR (FS-DFCB-OR), have been presented in an accompanying work. This paper scrutinizes the performance and the limitations of both DF- and FS-DFCB-OR for assessments of refractivity and gas density, in particular their precision, accuracy, and temperature dependence. It is shown that both refractivity and gas density can be assessed by FS-DFCB-OR with a precision in the 10$^{-9}$ range under STP conditions. It is demonstrated that the absolute accuracy is mainly limited by the accuracy by which the instantaneous deformation of the cavity or the higher order virial coefficients can be assessed. It is also shown that the internal accuracy, i.e. the accuracy by which the system can be characterized with respect to an internal standard, can be several orders of magnitude better than the absolute. It is concluded that the temperature dependence of FS-DFCB-OR is exceptionally small, typically in the 10$^{-8}$ to 10$^{-7}$/C range, and primarily caused by thermal expansion of the FPC-spacer material. Finally, this paper discusses means on how to design a FS-DFCB-or system for optimal performance and epitomizes the conclusions of this and our accompanying works regarding both DF- and FS-DFCB-OR in terms of performance and provides an outlook for both techniques. Our works can serve as a basis for future realizations of instrumentation for assessments of gas refractivity and density that can fully benefit from the extraordinary potential of FPC-OR.

physics.ins-det

Fast Switching Dual Fabry-Perot Cavity Optical Refractometry - Methodologies for Accurate Assessment of Gas Density

Dual Fabry-Perot cavity based optical refractometry (DFPC-OR) has a high potential for assessments of gas density. However, drifts of the FP cavity often limit its performance. We show that by the use of two narrow-linewidth fiber lasers locked to two high finesse cavities and Allan-Werle plots that drift-free DFPC-OR can be obtained for short measurement times (for which the drifts of the cavity can be disregarded). Based on this, a novel strategy, termed fast switching DFPC-OR (FS-DFPC-OR), is presented. A set of novel methodologies for assessment of both gas density and flow rates (in particular from small leaks) that are not restricted by the conventional limitations imposed by the drifts of the cavity are presented. The methodologies deal with assessments in both open and closed (finite-sized) compartments. They circumvent the problem with volumetric expansion, i.e. that the gas density in a measurement cavity is not the same as that in the closed external compartment that should be assessed, by performing a pair of measurements in rapid succession; the first one serves the purpose of assessing the density of the gas that has been transferred into the measurement cavity by the gas equilibration process, while the 2nd is used to automatically calibrate the system with respect to the relative volumes of the measurement cavity and the external compartment. The methodologies for assessments of leak rates comprise triple cavity evacuation assessments, comprising two measurements performed in rapid succession, supplemented by a 3rd measurement a certain time thereafter. A clear explanation of why the technique has such a small temperature dependence is given. It is concluded that FS-DFPC-OR constitutes a novel strategy that can be used for precise and accurate assessment of gas number density and gas flows under a variety of conditions, in particular non-temperature stabilized ones.

physics.ins-det

Drift-Free Fabry-Perot-Cavity-based Optical Refractometry -- Accurate Expressions for Assessments of Gas Refractivity and Density

Recent advancements in the field of Fabry-Perot cavity based optical refractometry (OR), FPC-OR, comprising the use of proposed novel methodologies based on drift-free Dual FPC-OR (DF-DFPC-OR), have alleviated much of earlier problems with FPC-OR, in particular drifts of the cavity spacer, and therefore open up for new levels of accurate characterization of gases. However, to be able to use these techniques for highly accurate assessments, general and explicit expressions are needed for how the gas density, ${\rho_n}$, is related to the refractivity of the gas, $n - 1$, and how the latter depends on the change in frequency of laser light that follows an evacuation of the cavity, $\Delta {\nu_l}$. This paper presents such relations that properly acknowledge the influence of all conceivable phenomena and higher order (non-linear) contributions to the assessment of these entities under drift-free conditions. The relative contributions of each of these phenomena to measurements of gas refractivity and density are individually assessed. It is shown, among other things, that, the influence of cavity deformation is larger for an open cavity (placed in a compartment in which gas is introduced) than a closed one; if not accounted for appropriately, under standard pressure and temperature conditions it can contribute to the accuracy of the technique with up to a few times 10$^{-3}$ if an open cavity is used, while it can be an order of magnitude smaller, i.e. in the order of 10$^{-4}$, for a well-designed closed cavity. It is also shown that the non-linearities from dispersion are smaller for the cases when relocking takes place than when it is not used. The expressions derived can serve as a basis for assessment of refractivity or gas density, and changes in such, in future realizations of OR in such a way that they can fully benefit from the extraordinary power of DF-DFPC-OR.

physics.ins-det

Investigation of force approximations in tethered cells simulations

Simulations of tethered cells in viscous sub-layers are frequently performed using the Stokes drag force, but without taking into account contributions from surface corrections, lift forces, buoyancy, the Basset force, the cells finite inertia, or added mass. In this work, we investigate to which extent such contributions influence, under a variety of hydrodynamic conditions, the force at the anchor point of a tethered cell and the survival probability of a bacterium that is attached to a host by either a slip or a catch bond via a tether with a few different biomechanical properties. We show that a consequence of not including some of these contributions is that the force to which a bond is exposed can be significantly underestimated; in general by ~32-46 %, where the influence of the surface corrections dominate (the parallel and normal correction coefficients contribute with ~5-8 or 23-26 %, respectively). The Basset force is a major contributor, up to 20 %, for larger cells and shear rates. The lift force and inertia contribute when cells with radii >3 micrometer reside in shear rates >2000 1/s. Buoyancy contributes significantly for cells with radii >3 micrometer in shear rates <10 1/s. Since the lifetime of a bond depends strongly on the force, both the level of approximations and the biomechanical model of the tether significantly affect the survival probability of tethered bacteria. For a cell attached with a FimH-mannose bond and an extendable tether in a shear rate of 3000 1/s, neglecting the surface correction coefficients or the Basset force can imply that the survival probability is overestimated by more than an order of magnitude. This work thus shows that in order to quantitatively assess bacterial attachment forces and survival probabilities, both the fluid forces and the tether properties need to be modeled accurately.

physics.bio-ph

The biomechanical properties of F1C pili

Uropathogenic Escherichia coli (UPEC) express various kinds of organelles, so-called pili or fimbriae, that mediate adhesion to host tissue in the urinary tract through specific receptor-adhesin interactions. The biomechanical properties of these pili have been considered important for the ability of bacteria to withstand shear forces from rinsing urine flows. Force measuring optical tweezers have been used to characterize individual organelles of F1C type expressed by UPEC bacteria with respect to such properties. Qualitatively, the force-vs.-elongation response was found to be similar to that of other types of helix-like pili expressed by UPEC, i.e. type 1, P, and S, with force-induced elongation in three regions of which one represents the important uncoiling mechanism of the helix-like quaternary structure. Quantitatively, the steady-state uncoiling force was assessed to 26.4(1.4) pN, which is similar to those of other pili (which range from 21 pN for SI to 30 pN for type 1). The corner velocity for dynamic response (1400 nm/s) was found to be larger than those of the other pili (400 -700 nm/s for S and P pili, and 6 nm/s for type 1). The kinetics were found to be faster, with a thermal opening rate of 17 Hz, a few times higher than S and P pili, and three orders of magnitude times higher than type 1. These data suggest that F1C pili are, like P and S pili, evolutionary-selected to primarily withstand the conditions expressed in the upper urinary tract.

physics.bio-ph

Damping properties of type 1 fimbriae

Type 1 fimbriae mediate adhesion of uropathogenic Escherichia coli (UPEC) to host cells. It has been hypothesized that fimbriae can, by their ability to uncoil under exposure to force, reduce fluid shear stress on the adhesin-receptor interaction by which the bacterium adheres to the surface. In this work we develop a model that describes how the force on the adhesin-receptor interaction of a type 1 fimbriae varies as a bacterium is affected by a time dependent fluid flow mimicking in vivo conditions. The model combines in vivo hydrodynamic conditions with previously assessed biomechanical properties of the fimbriae. Numerical methods are used to solve for the motion and adhesion force under the presence of time dependent fluid profiles. It is found that a bacterium tethered with a type 1 pilus will experience significantly reduced shear stress for moderate to high flow velocities and that the maximum stress the adhesin will experience is limited to ~120 pN, which is sufficient to activate the conformational change of the FimH adhesin into its stronger state but also lower than the force required for breaking it under rapid loading. Our model thus supports the assumption that the type 1 fimbriae shaft and the FimH adhesin-receptor interaction are optimized to each other, and that they give piliated bacteria significant advantages in rapidly changing fluidic environments.

physics.bio-ph

Damping effect of helix-like pili

Biopolymers are vital structures for many living organisms; for a variety of bacteria, adhesion polymers play a crucial role for the initiation of colonization. Some bacteria express, on their surface, attachment organelles (pili) that comprise subunits formed into stiff helix-like structures that possess unique biomechanical properties. These helix-like structures possess a high degree of flexibility that gives the biopolymers a unique extendibility. This has been considered beneficial for piliated bacteria adhering to host surfaces in the presence of a fluid flow. We show in this work that helix-like pili have the ability to act as efficient dampers of force that can, for a limited time, lower the load on the force-mediating adhesin-receptor bond on the tip of an individual pilus. The model presented is applied to bacteria adhering with a single pilus of either of the two most common types expressed by uropathogenic Escherichia coli, P or type 1 pili, subjected to realistic flows. The results indicate that for moderate flows (~25 mm/s) the force experienced by the adhesin-receptor interaction at the tip of the pilus can be reduced by a factor of ~6 and ~4, respectively. The uncoiling ability provides a bacterium with a "go with the flow" possibility that acts as a damping. It is surmised that this can be an important factor for the initial part of the adhesion process, in particular in turbulent flows, and thereby be of use for bacteria in their striving to survive a natural defense such as fluid rinsing actions.

physics.bio-ph

Multibody simulation of adhesion pili

We present a coarse grained rigid multibody model of a subunit assembled helix-like polymer, e.g., adhesion pili expressed by bacteria, that is capable of describing the polymers force-extension response. With building blocks representing individual subunits the model appropriately describes the complex behavior of pili expressed by the gram-negative uropathogenic Escherichia coli bacteria under the action of an external force. Numerical simulations show that the dynamics of the model, which include both the effects of unwinding and rewinding, are in good quantitative agreement with the characteristic force-extension response as observed experimentally for type 1 and P pili. By tuning the model, it is also possible to reproduce the force-extension response in the presence of anti-shaft antibodies, which dramatically changes the mechanical properties. Thus, the model and the results in this work give enhanced understanding of how a pilus unwinds under action of external forces and provide new perspective of the complex bacterial adhesion processes.

physics.bio-ph

Dynamic properties of bacterial pili measured by optical tweezers

The ability of uropathogenic Escherichia coli (UPEC) to cause urinary tract infections is dependent on their ability to colonize the uroepithelium. Infecting bacteria ascend the urethra to the bladder and then kidneys by attaching to the uroepithelial cells via the differential expression of adhesins. P pili are associated with pyelonephritis, the more severe infection of the kidneys. In order to find means to treat pyelonephritis, it is therefore of interest to investigate the properties P pili. The mechanical behavior of individual P pili of uropathogenic Escherichia coli has recently been investigated using optical tweezers. P pili, whose main part constitutes the PapA rod, composed of ~1000 PapA subunits in a helical arrangement, are distributed over the bacterial surface and mediate adhesion to host cells. We have earlier studied P pili regarding its stretching/elongation properties where we have found and characterized three different elongation regions, of which one constitute an unfolding of the quaternary (helical) structure of the PapA rod. It was shown that this unfolding takes place at an elongation independent force of 27 pN. We have also recently performed studies on its folding properties and shown that the unfolding/folding of the PapA rod is completely reversible. Here we present a study of the dynamical properties of the PapA rod. We show, among other things, that the unfolding force increases and that the folding force decreases with the speed of unfolding and folding respectively. Moreover, the PapA rod can be folded-unfolded a significant number of times without loosing its characteristics, a phenomenon that is believed to be important for the bacterium to keep close contact to the host tissue and consequently helps the bacterium to colonize the host tissue.

physics.bio-ph