arXiv ScienceSearch

arXiv · 1704.01185

Fast Switching Dual Fabry-Perot-Cavity-based Optical Refractometry for Assessment of Gas Refractivity and Density - Estimates of Its Precision, Accuracy, and Temperature Dependence

Abstract

Dual Fabry-Perot-Cavity-based Optical Refractometry (DFCB-OR) have been shown to have excellent potential for characterization of gases, in particular their refractivity and density. However, its performance has in practice been found to be limited by drifts. To remedy this, drift-free DFPC-OR (DF-DFCB-OR) has recently been proposed. Suggested methodologies for realization of a specific type of DF-DFCB-OR, termed Fast Switching DFCB-OR (FS-DFCB-OR), have been presented in an accompanying work. This paper scrutinizes the performance and the limitations of both DF- and FS-DFCB-OR for assessments of refractivity and gas density, in particular their precision, accuracy, and temperature dependence. It is shown that both refractivity and gas density can be assessed by FS-DFCB-OR with a precision in the 10$^{-9}$ range under STP conditions. It is demonstrated that the absolute accuracy is mainly limited by the accuracy by which the instantaneous deformation of the cavity or the higher order virial coefficients can be assessed. It is also shown that the internal accuracy, i.e. the accuracy by which the system can be characterized with respect to an internal standard, can be several orders of magnitude better than the absolute. It is concluded that the temperature dependence of FS-DFCB-OR is exceptionally small, typically in the 10$^{-8}$ to 10$^{-7}$/C range, and primarily caused by thermal expansion of the FPC-spacer material. Finally, this paper discusses means on how to design a FS-DFCB-or system for optimal performance and epitomizes the conclusions of this and our accompanying works regarding both DF- and FS-DFCB-OR in terms of performance and provides an outlook for both techniques. Our works can serve as a basis for future realizations of instrumentation for assessments of gas refractivity and density that can fully benefit from the extraordinary potential of FPC-OR.

Explore related subjects

Keep this discovery

BibTeXRIS

Martin Zelan, Isak Silander, Thomas Hausmaninger, Ove Axner. 2017-04-03. Fast Switching Dual Fabry-Perot-Cavity-based Optical Refractometry for Assessment of Gas Refractivity and Density - Estimates of Its Precision, Accuracy, and Temperature Dependence. https://arxiv.org/abs/1704.01185

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det