arXiv ScienceSearch

arXiv · 1704.01186

Fast Switching Dual Fabry-Perot Cavity Optical Refractometry - Methodologies for Accurate Assessment of Gas Density

Abstract

Dual Fabry-Perot cavity based optical refractometry (DFPC-OR) has a high potential for assessments of gas density. However, drifts of the FP cavity often limit its performance. We show that by the use of two narrow-linewidth fiber lasers locked to two high finesse cavities and Allan-Werle plots that drift-free DFPC-OR can be obtained for short measurement times (for which the drifts of the cavity can be disregarded). Based on this, a novel strategy, termed fast switching DFPC-OR (FS-DFPC-OR), is presented. A set of novel methodologies for assessment of both gas density and flow rates (in particular from small leaks) that are not restricted by the conventional limitations imposed by the drifts of the cavity are presented. The methodologies deal with assessments in both open and closed (finite-sized) compartments. They circumvent the problem with volumetric expansion, i.e. that the gas density in a measurement cavity is not the same as that in the closed external compartment that should be assessed, by performing a pair of measurements in rapid succession; the first one serves the purpose of assessing the density of the gas that has been transferred into the measurement cavity by the gas equilibration process, while the 2nd is used to automatically calibrate the system with respect to the relative volumes of the measurement cavity and the external compartment. The methodologies for assessments of leak rates comprise triple cavity evacuation assessments, comprising two measurements performed in rapid succession, supplemented by a 3rd measurement a certain time thereafter. A clear explanation of why the technique has such a small temperature dependence is given. It is concluded that FS-DFPC-OR constitutes a novel strategy that can be used for precise and accurate assessment of gas number density and gas flows under a variety of conditions, in particular non-temperature stabilized ones.

Explore related subjects

Keep this discovery

BibTeXRIS

Isak Silander, Thomas Hausmaninger, Michael Bradley, Martin Zelan, Ove Axner. 2017-04-03. Fast Switching Dual Fabry-Perot Cavity Optical Refractometry - Methodologies for Accurate Assessment of Gas Density. https://arxiv.org/abs/1704.01186

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det