arXiv Science⌕ Search

arXiv subjects

Jie Ying Wu

Publications and source records attributed to Jie Ying Wu.

At least 37 records · Page 2Linked to original sources

A Supervised Autonomous Resection and Retraction Framework for Transurethral Enucleation of the Prostatic Median Lobe

Concentric tube robots (CTRs) offer dexterous motion at millimeter scales, enabling minimally invasive procedures through natural orifices. This work presents a coordinated model-based resection planner and learning-based retraction network that work together to enable semi-autonomous tissue resection using a dual-arm transurethral concentric tube robot (the Virtuoso). The resection planner operates directly on segmented CT volumes of prostate phantoms, automatically generating tool trajectories for a three-phase median lobe resection workflow: left/median trough resection, right/median trough resection, and median blunt dissection. The retraction network, PushCVAE, trained on surgeon demonstrations, generates retractions according to the procedural phase. The procedure is executed under Level-3 (supervised) autonomy on a prostate phantom composed of hydrogel materials that replicate the mechanical and cutting properties of tissue. As a feasibility study, we demonstrate that our combined autonomous system achieves a 97.1% resection of the targeted volume of the median lobe. Our study establishes a foundation for image-guided autonomy in transurethral robotic surgery and represents a first step toward fully automated minimally-invasive prostate enucleation.

cs.RO↗

Monocular absolute depth estimation from endoscopy via domain-invariant feature learning and latent consistency

Monocular depth estimation (MDE) is a critical task to guide autonomous medical robots. However, obtaining absolute (metric) depth from an endoscopy camera in surgical scenes is difficult, which limits supervised learning of depth on real endoscopic images. Current image-level unsupervised domain adaptation methods translate synthetic images with known depth maps into the style of real endoscopic frames and train depth networks using these translated images with their corresponding depth maps. However a domain gap often remains between real and translated synthetic images. In this paper, we present a latent feature alignment method to improve absolute depth estimation by reducing this domain gap in the context of endoscopic videos of the central airway. Our methods are agnostic to the image translation process and focus on the depth estimation itself. Specifically, the depth network takes translated synthetic and real endoscopic frames as input and learns latent domain-invariant features via adversarial learning and directional feature consistency. The evaluation is conducted on endoscopic videos of central airway phantoms with manually aligned absolute depth maps. Compared to state-of-the-art MDE methods, our approach achieves superior performance on both absolute and relative depth metrics, and consistently improves results across various backbones and pretrained weights. Our code is available at https://github.com/MedICL-VU/MDE.

cs.CV↗

Augmented Reality-based Guidance with Deformable Registration in Head and Neck Tumor Resection

Head and neck squamous cell carcinoma (HNSCC) has one of the highest rates of recurrence cases among solid malignancies. Recurrence rates can be reduced by improving positive margins localization. Frozen section analysis (FSA) of resected specimens is the gold standard for intraoperative margin assessment. However, because of the complex 3D anatomy and the significant shrinkage of resected specimens, accurate margin relocation from specimen back onto the resection site based on FSA results remains challenging. We propose a novel deformable registration framework that uses both the pre-resection upper surface and the post-resection site of the specimen to incorporate thickness information into the registration process. The proposed method significantly improves target registration error (TRE), demonstrating enhanced adaptability to thicker specimens. In tongue specimens, the proposed framework improved TRE by up to 33% as compared to prior deformable registration. Notably, tongue specimens exhibit complex 3D anatomies and hold the highest clinical significance compared to other head and neck specimens from the buccal and skin. We analyzed distinct deformation behaviors in different specimens, highlighting the need for tailored deformation strategies. To further aid intraoperative visualization, we also integrated this framework with an augmented reality-based auto-alignment system. The combined system can accurately and automatically overlay the deformed 3D specimen mesh with positive margin annotation onto the resection site. With a pilot study of the AR guided framework involving two surgeons, the integrated system improved the surgeons' average target relocation error from 9.8 cm to 4.8 cm.

eess.IV↗

Sensorless Remote Center of Motion Misalignment Estimation

Laparoscopic surgery constrains instrument motion around a fixed pivot point at the incision into a patient to minimize tissue trauma. Surgical robots achieve this through either hardware to software-based remote center of motion (RCM) constraints. However, accurate RCM alignment is difficult due to manual trocar placement, patient motion, and tissue deformation. Misalignment between the robot's RCM point and the patient incision site can cause unsafe forces at the incision site. This paper presents a sensorless force estimation-based framework for dynamically assessing and optimizing RCM misalignment in robotic surgery. Our experiments demonstrate that misalignment exceeding 20 mm can generate large enough forces to potentially damage tissue, emphasizing the need for precise RCM positioning. For misalignment $D\geq $ 20 mm, our optimization algorithm estimates the RCM offset with an absolute error within 5 mm. Accurate RCM misalignment estimation is a step toward automated RCM misalignment compensation, enhancing safety and reducing tissue damage in robotic-assisted laparoscopic surgery.

cs.RO↗

Focus on the Experts: Co-designing an Augmented Reality Eye-Gaze Tracking System with Surgical Trainees to Improve Endoscopic Instruction

The current apprenticeship model for surgical training requires a high level of supervision, which does not scale well to meet the growing need for more surgeons. Many endoscopic procedures are directly taught in the operating room (OR) while the attending surgeon and trainee operate on patients. The need to prioritize patient care limits the trainees' opportunities to experiment and receive feedback on their performance. Augmented reality (AR) has the potential to increase efficiency in endoscopic surgical training, but additional research is critical to understanding the needs of surgical trainees to inform the design of AR training systems. Therefore, we worked with 18 surgical trainees to understand the strengths, limitations, and unmet needs of their current training environment and to co-design an AR eye-gaze tracking system based on their preferences. Trainees emphasized the need to practice the 2D to 3D mapping needed to properly familiarize oneself with the anatomy of patients to prepare for real surgery. The trainees felt that an AR-based eye gaze tracking system would be a useful supplemental training method that would improve their learning in OR cases without detracting from patient care. To tailor the AR system to their needs, they co-designed features to improve their ability to track the attending surgeon's eye gaze and to provide a real-time, interactive system. Our results are valuable in shaping the endoscopic training modules by generating user-informed guidelines to design future collaborative AR-based eye-gaze tracking systems.

cs.HC↗

NAVIUS: Navigated Augmented Reality Visualization for Ureteroscopic Surgery

Ureteroscopy is the standard of care for diagnosing and treating kidney stones and tumors. However, current ureteroscopes have a limited field of view, requiring significant experience to adequately navigate the renal collecting system. This is evidenced by the fact that inexperienced surgeons have higher rates of missed stones. One-third of patients with residual stones require re-operation within 20 months. In order to aid surgeons to fully explore the kidney, this study presents the Navigated Augmented Reality Visualization for Ureteroscopic Surgery (NAVIUS) system. NAVIUS assists surgeons by providing 3D maps of the target anatomy, real-time scope positions, and preoperative imaging overlays. To enable real-time navigation and visualization, we integrate an electromagnetic tracker-based navigation pipeline with augmented reality visualizations. NAVIUS connects to 3D Slicer and Unity with OpenIGTLink, and uses HoloLens 2 as a holographic interface. We evaluate NAVIUS through a user study where surgeons conducted ureteroscopy on kidney phantoms with and without visual guidance. With our proposed system, we observed that surgeons explored more areas within the collecting system with NAVIUS (average 23.73% increase), and NASA-TLX metrics were improved (up to 27.27%). NAVIUS acts as a step towards better surgical outcomes and surgeons' experience. The codebase for the system will be available at: https://github.com/vu-maple-lab/NAVIUS.

cs.HC↗

From Monocular Vision to Autonomous Action: Guiding Tumor Resection via 3D Reconstruction

Surgical automation requires precise guidance and understanding of the scene. Current methods in the literature rely on bulky depth cameras to create maps of the anatomy, however this does not translate well to space-limited clinical applications. Monocular cameras are small and allow minimally invasive surgeries in tight spaces but additional processing is required to generate 3D scene understanding. We propose a 3D mapping pipeline that uses only RGB images to create segmented point clouds of the target anatomy. To ensure the most precise reconstruction, we compare different structure from motion algorithms' performance on mapping the central airway obstructions, and test the pipeline on a downstream task of tumor resection. In several metrics, including post-procedure tissue model evaluation, our pipeline performs comparably to RGB-D cameras and, in some cases, even surpasses their performance. These promising results demonstrate that automation guidance can be achieved in minimally invasive procedures with monocular cameras. This study is a step toward the complete autonomy of surgical robots.

cs.CV↗

Multi-Modal Gesture Recognition from Video and Surgical Tool Pose Information via Motion Invariants

Recognizing surgical gestures in real-time is a stepping stone towards automated activity recognition, skill assessment, intra-operative assistance, and eventually surgical automation. The current robotic surgical systems provide us with rich multi-modal data such as video and kinematics. While some recent works in multi-modal neural networks learn the relationships between vision and kinematics data, current approaches treat kinematics information as independent signals, with no underlying relation between tool-tip poses. However, instrument poses are geometrically related, and the underlying geometry can aid neural networks in learning gesture representation. Therefore, we propose combining motion invariant measures (curvature and torsion) with vision and kinematics data using a relational graph network to capture the underlying relations between different data streams. We show that gesture recognition improves when combining invariant signals with tool position, achieving 90.3\% frame-wise accuracy on the JIGSAWS suturing dataset. Our results show that motion invariant signals coupled with position are better representations of gesture motion compared to traditional position and quaternion representations. Our results highlight the need for geometric-aware modeling of kinematics for gesture recognition.

cs.CV↗

EndoPBR: Material and Lighting Estimation for Photorealistic Surgical Simulations via Physically-based Rendering

The lack of labeled datasets in 3D vision for surgical scenes inhibits the development of robust 3D reconstruction algorithms in the medical domain. Despite the popularity of Neural Radiance Fields and 3D Gaussian Splatting in the general computer vision community, these systems have yet to find consistent success in surgical scenes due to challenges such as non-stationary lighting and non-Lambertian surfaces. As a result, the need for labeled surgical datasets continues to grow. In this work, we introduce a differentiable rendering framework for material and lighting estimation from endoscopic images and known geometry. Compared to previous approaches that model lighting and material jointly as radiance, we explicitly disentangle these scene properties for robust and photorealistic novel view synthesis. To disambiguate the training process, we formulate domain-specific properties inherent in surgical scenes. Specifically, we model the scene lighting as a simple spotlight and material properties as a bidirectional reflectance distribution function, parameterized by a neural network. By grounding color predictions in the rendering equation, we can generate photorealistic images at arbitrary camera poses. We evaluate our method with various sequences from the Colonoscopy 3D Video Dataset and show that our method produces competitive novel view synthesis results compared with other approaches. Furthermore, we demonstrate that synthetic data can be used to develop 3D vision algorithms by finetuning a depth estimation model with our rendered outputs. Overall, we see that the depth estimation performance is on par with fine-tuning with the original real images.

cs.CV↗

Gravity Compensation of the dVRK-Si Patient Side Manipulator based on Dynamic Model Identification

The da Vinci Research Kit (dVRK, also known as dVRK Classic) is an open-source teleoperated surgical robotic system whose hardware is obtained from the first generation da Vinci Surgical System (Intuitive, Sunnyvale, CA, USA). The dVRK has greatly facilitated research in robot-assisted surgery over the past decade and helped researchers address multiple major challenges in this domain. Recently, the dVRK-Si system, a new version of the dVRK which uses mechanical components from the da Vinci Si Surgical System, became available to the community. The major difference between the first generation da Vinci and the da Vinci Si is in the structural upgrade of the Patient Side Manipulator (PSM). Because of this upgrade, the gravity of the dVRK-Si PSM can no longer be ignored as in the dVRK Classic. The high gravity offset may lead to relatively low control accuracy and longer response time. In addition, although substantial progress has been made in addressing the dynamic model identification problem for the dVRK Classic, further research is required on model-based control for the dVRK-Si, due to differences in mechanical components and the demand for enhanced control performance. To address these problems, in this work, we present (1) a novel full kinematic model of the dVRK-Si PSM, and (2) a gravity compensation approach based on the dynamic model identification.

cs.RO↗

An Effectiveness Study Across Baseline and Learning-based Force Estimation Methods on the da Vinci Research Kit Si System

Robot-assisted minimally invasive surgery, such as through the da Vinci systems, improves precision and patient outcomes. However, da Vinci systems prior to da Vinci 5, lacked direct force-sensing capabilities, forcing surgeons to operate without the haptic feedback they get through laparoscopy. Our prior work restored force sensing through machine learning-based force estimation for the da Vinci Research Kit (dVRK) Classic. This study extends our previous method to the newer dVRK system, the dVRK-Si. Additionally, we benchmark the performance of the learning-based algorithm against baseline methods (which make simplifying assumptions on the torque) to study how the two systems differ. Results show the learning-based method achieves an average root-mean-square-error (RMSE) of 5.21\%, for the dVRK-Si, which is comparable to the dVRK Classic. In both systems, the learning-based method outperforms baselines, but the difference is much larger in the dVRK-Si. Nonetheless, dVRK-Si force estimation accuracy lags behind the dVRK Classic, with RMSE 2 to 3 times higher. Further analysis reveals poor PID control in the dVRK-Si. We hypothesize that this is due to the lack of gravity compensation, as unlike the dVRK Classic, the dVRK-Si is not mechanically balanced. This study advances the understanding of learning-based force estimation and is the first work to characterize the dynamics of the new dVRK-Si system.

cs.RO↗

A Hybrid Model and Learning-Based Force Estimation Framework for Surgical Robots

Haptic feedback to the surgeon during robotic surgery would enable safer and more immersive surgeries but estimating tissue interaction forces at the tips of robotically controlled surgical instruments has proven challenging. Few existing surgical robots can measure interaction forces directly and the additional sensor may limit the life of instruments. We present a hybrid model and learning-based framework for force estimation for the Patient Side Manipulators (PSM) of a da Vinci Research Kit (dVRK). The model-based component identifies the dynamic parameters of the robot and estimates free-space joint torque, while the learning-based component compensates for environmental factors, such as the additional torque caused by trocar interaction between the PSM instrument and the patient's body wall. We evaluate our method in an abdominal phantom and achieve an error in force estimation of under 10% normalized root-mean-squared error. We show that by using a model-based method to perform dynamics identification, we reduce reliance on the training data covering the entire workspace. Although originally developed for the dVRK, the proposed method is a generalizable framework for other compliant surgical robots. The code is available at https://github.com/vu-maple-lab/dvrk_force_estimation.

cs.RO↗

MeshBrush: Painting the Anatomical Mesh with Neural Stylization for Endoscopy

Style transfer is a promising approach to close the sim-to-real gap in medical endoscopy. Rendering synthetic endoscopic videos by traversing pre-operative scans (such as MRI or CT) can generate structurally accurate simulations as well as ground truth camera poses and depth maps. Although image-to-image (I2I) translation models such as CycleGAN can imitate realistic endoscopic images from these simulations, they are unsuitable for video-to-video synthesis due to the lack of temporal consistency, resulting in artifacts between frames. We propose MeshBrush, a neural mesh stylization method to synthesize temporally consistent videos with differentiable rendering. MeshBrush uses the underlying geometry of patient imaging data while leveraging existing I2I methods. With learned per-vertex textures, the stylized mesh guarantees consistency while producing high-fidelity outputs. We demonstrate that mesh stylization is a promising approach for creating realistic simulations for downstream tasks such as training networks and preoperative planning. Although our method is tested and designed for ureteroscopy, its components are transferable to general endoscopic and laparoscopic procedures. The code will be made public on GitHub.

eess.IV↗

Zero-shot Prompt-based Video Encoder for Surgical Gesture Recognition

Purpose: In order to produce a surgical gesture recognition system that can support a wide variety of procedures, either a very large annotated dataset must be acquired, or fitted models must generalize to new labels (so called "zero-shot" capability). In this paper we investigate the feasibility of latter option. Methods: Leveraging the Bridge-Prompt framework, we prompt-tune a pre-trained vision-text model (CLIP) for gesture recognition in surgical videos. This can utilize extensive outside video data such as text, but also make use of label meta-data and weakly supervised contrastive losses. Results: Our experiments show that prompt-based video encoder outperforms standard encoders in surgical gesture recognition tasks. Notably, it displays strong performance in zero-shot scenarios, where gestures/tasks that were not provided during the encoder training phase are included in the prediction phase. Additionally, we measure the benefit of inclusion text descriptions in the feature extractor training schema. Conclusion Bridge-Prompt and similar pre-trained+prompt-tuned video encoder models present significant visual representation for surgical robotics, especially in gesture recognition tasks. Given the diverse range of surgical tasks (gestures), the ability of these models to zero-shot transfer without the need for any task (gesture) specific retraining makes them invaluable.

cs.CV↗

Depth Anything in Medical Images: A Comparative Study

Monocular depth estimation (MDE) is a critical component of many medical tracking and mapping algorithms, particularly from endoscopic or laparoscopic video. However, because ground truth depth maps cannot be acquired from real patient data, supervised learning is not a viable approach to predict depth maps for medical scenes. Although self-supervised learning for MDE has recently gained attention, the outputs are difficult to evaluate reliably and each MDE's generalizability to other patients and anatomies is limited. This work evaluates the zero-shot performance of the newly released Depth Anything Model on medical endoscopic and laparoscopic scenes. We compare the accuracy and inference speeds of Depth Anything with other MDE models trained on general scenes as well as in-domain models trained on endoscopic data. Our findings show that although the zero-shot capability of Depth Anything is quite impressive, it is not necessarily better than other models in both speed and performance. We hope that this study can spark further research in employing foundation models for MDE in medical scenes.

cs.CV↗

Eye Tracking for Tele-robotic Surgery: A Comparative Evaluation of Head-worn Solutions

Purpose: Metrics derived from eye-gaze-tracking and pupillometry show promise for cognitive load assessment, potentially enhancing training and patient safety through user-specific feedback in tele-robotic surgery. However, current eye-tracking solutions' effectiveness in tele-robotic surgery is uncertain compared to everyday situations due to close-range interactions causing extreme pupil angles and occlusions. To assess the effectiveness of modern eye-gaze-tracking solutions in tele-robotic surgery, we compare the Tobii Pro 3 Glasses and Pupil Labs Core, evaluating their pupil diameter and gaze stability when integrated with the da Vinci Research Kit (dVRK). Methods: The study protocol includes a nine-point gaze calibration followed by pick-and-place task using the dVRK and is repeated three times. After a final calibration, users view a 3x3 grid of AprilTags, focusing on each marker for 10 seconds, to evaluate gaze stability across dVRK-screen positions with the L2-norm. Different gaze calibrations assess calibration's temporal deterioration due to head movements. Pupil diameter stability is evaluated using the FFT from the pupil diameter during the pick-and-place tasks. Users perform this routine with both head-worn eye-tracking systems. Results: Data collected from ten users indicate comparable pupil diameter stability. FFTs of pupil diameters show similar amplitudes in high-frequency components. Tobii Glasses show more temporal gaze stability compared to Pupil Labs, though both eye trackers yield a similar 4cm error in gaze estimation without an outdated calibration. Conclusion: Both eye trackers demonstrate similar stability of the pupil diameter and gaze, when the calibration is not outdated, indicating comparable eye-tracking and pupillometry performance in tele-robotic surgery settings.

cs.HC↗

Rethinking Causality-driven Robot Tool Segmentation with Temporal Constraints

Purpose: Vision-based robot tool segmentation plays a fundamental role in surgical robots and downstream tasks. CaRTS, based on a complementary causal model, has shown promising performance in unseen counterfactual surgical environments in the presence of smoke, blood, etc. However, CaRTS requires over 30 iterations of optimization to converge for a single image due to limited observability. Method: To address the above limitations, we take temporal relation into consideration and propose a temporal causal model for robot tool segmentation on video sequences. We design an architecture named Temporally Constrained CaRTS (TC-CaRTS). TC-CaRTS has three novel modules to complement CaRTS - temporal optimization pipeline, kinematics correction network, and spatial-temporal regularization. Results: Experiment results show that TC-CaRTS requires much fewer iterations to achieve the same or better performance as CaRTS. TC- CaRTS also has the same or better performance in different domains compared to CaRTS. All three modules are proven to be effective. Conclusion: We propose TC-CaRTS, which takes advantage of temporal constraints as additional observability. We show that TC-CaRTS outperforms prior work in the robot tool segmentation task with improved convergence speed on test datasets from different domains.

cs.RO↗

CaRTS: Causality-driven Robot Tool Segmentation from Vision and Kinematics Data

Vision-based segmentation of the robotic tool during robot-assisted surgery enables downstream applications, such as augmented reality feedback, while allowing for inaccuracies in robot kinematics. With the introduction of deep learning, many methods were presented to solve instrument segmentation directly and solely from images. While these approaches made remarkable progress on benchmark datasets, fundamental challenges pertaining to their robustness remain. We present CaRTS, a causality-driven robot tool segmentation algorithm, that is designed based on a complementary causal model of the robot tool segmentation task. Rather than directly inferring segmentation masks from observed images, CaRTS iteratively aligns tool models with image observations by updating the initially incorrect robot kinematic parameters through forward kinematics and differentiable rendering to optimize image feature similarity end-to-end. We benchmark CaRTS with competing techniques on both synthetic as well as real data from the dVRK, generated in precisely controlled scenarios to allow for counterfactual synthesis. On training-domain test data, CaRTS achieves a Dice score of 93.4 that is preserved well (Dice score of 91.8) when tested on counterfactually altered test data, exhibiting low brightness, smoke, blood, and altered background patterns. This compares favorably to Dice scores of 95.0 and 86.7, respectively, of the SOTA image-based method. Future work will involve accelerating CaRTS to achieve video framerate and estimating the impact occlusion has in practice. Despite these limitations, our results are promising: In addition to achieving high segmentation accuracy, CaRTS provides estimates of the true robot kinematics, which may benefit applications such as force estimation. Code is available at: https://github.com/hding2455/CaRTS

cs.RO↗