arXiv Science⌕ Search

arXiv subjects

Jie Ying Wu

Publications and source records attributed to Jie Ying Wu.

43 records · Page 3Linked to original sources

Relational Graph Learning on Visual and Kinematics Embeddings for Accurate Gesture Recognition in Robotic Surgery

Automatic surgical gesture recognition is fundamentally important to enable intelligent cognitive assistance in robotic surgery. With recent advancement in robot-assisted minimally invasive surgery, rich information including surgical videos and robotic kinematics can be recorded, which provide complementary knowledge for understanding surgical gestures. However, existing methods either solely adopt uni-modal data or directly concatenate multi-modal representations, which can not sufficiently exploit the informative correlations inherent in visual and kinematics data to boost gesture recognition accuracies. In this regard, we propose a novel online approach of multi-modal relational graph network (i.e., MRG-Net) to dynamically integrate visual and kinematics information through interactive message propagation in the latent feature space. In specific, we first extract embeddings from video and kinematics sequences with temporal convolutional networks and LSTM units. Next, we identify multi-relations in these multi-modal embeddings and leverage them through a hierarchical relational graph learning module. The effectiveness of our method is demonstrated with state-of-the-art results on the public JIGSAWS dataset, outperforming current uni-modal and multi-modal methods on both suturing and knot typing tasks. Furthermore, we validated our method on in-house visual-kinematics datasets collected with da Vinci Research Kit (dVRK) platforms in two centers, with consistent promising performance achieved.

cs.CV↗

An Interpretable Approach to Automated Severity Scoring in Pelvic Trauma

Pelvic ring disruptions result from blunt injury mechanisms and are often found in patients with multi-system trauma. To grade pelvic fracture severity in trauma victims based on whole-body CT, the Tile AO/OTA classification is frequently used. Due to the high volume of whole-body trauma CTs generated in busy trauma centers, an automated approach to Tile classification would provide substantial value, e.,g., to prioritize the reading queue of the attending trauma radiologist. In such scenario, an automated method should perform grading based on a transparent process and based on interpretable features to enable interaction with human readers and lower their workload by offering insights from a first automated read of the scan. This paper introduces an automated yet interpretable pelvic trauma decision support system to assist radiologists in fracture detection and Tile grade classification. The method operates similarly to human interpretation of CT scans and first detects distinct pelvic fractures on CT with high specificity using a Faster-RCNN model that are then interpreted using a structural causal model based on clinical best practices to infer an initial Tile grade. The Bayesian causal model and finally, the object detector are then queried for likely co-occurring fractures that may have been rejected initially due to the highly specific operating point of the detector, resulting in an updated list of detected fractures and corresponding final Tile grade. Our method is transparent in that it provides finding location and type using the object detector, as well as information on important counterfactuals that would invalidate the system's recommendation and achieves an AUC of 83.3%/85.1% for translational/rotational instability. Despite being designed for human-machine teaming, our approach does not compromise on performance compared to previous black-box approaches.

eess.IV↗

Estimation of Trocar and Tool Interaction Forces on the da Vinci Research Kit with Two-Step Deep Learning

Measurement of environment interaction forces during robotic minimally-invasive surgery would enable haptic feedback to the surgeon, thereby solving one long-standing limitation. Estimating this force from existing sensor data avoids the challenge of retrofitting systems with force sensors, but is difficult due to mechanical effects such as friction and compliance in the robot mechanism. We have previously shown that neural networks can be trained to estimate the internal robot joint torques, thereby enabling estimation of external forces. In this work, we extend the method to estimate external Cartesian forces and torques, and also present a two-step approach to adapt to the specific surgical setup by compensating for forces due to the interactions between the instrument shaft and cannula seal and between the trocar and patient body. Experiments show that this approach provides estimates of external forces and torques within a mean root-mean-square error (RMSE) of 2 N and 0.08 Nm, respectively. Furthermore, the two-step approach can add as little as 5 minutes to the surgery setup time, with about 4 minutes to collect intraoperative training data and 1 minute to train the second-step network.

cs.RO↗

Multimodal and self-supervised representation learning for automatic gesture recognition in surgical robotics

Self-supervised, multi-modal learning has been successful in holistic representation of complex scenarios. This can be useful to consolidate information from multiple modalities which have multiple, versatile uses. Its application in surgical robotics can lead to simultaneously developing a generalised machine understanding of the surgical process and reduce the dependency on quality, expert annotations which are generally difficult to obtain. We develop a self-supervised, multi-modal representation learning paradigm that learns representations for surgical gestures from video and kinematics. We use an encoder-decoder network configuration that encodes representations from surgical videos and decodes them to yield kinematics. We quantitatively demonstrate the efficacy of our learnt representations for gesture recognition (with accuracy between 69.6 % and 77.8 %), transfer learning across multiple tasks (with accuracy between 44.6 % and 64.8 %) and surgeon skill classification (with accuracy between 76.8 % and 81.2 %). Further, we qualitatively demonstrate that our self-supervised representations cluster in semantically meaningful properties (surgeon skill and gestures).

cs.CV↗

A County-level Dataset for Informing the United States' Response to COVID-19

As the coronavirus disease 2019 (COVID-19) continues to be a global pandemic, policy makers have enacted and reversed non-pharmaceutical interventions with various levels of restrictions to limit its spread. Data driven approaches that analyze temporal characteristics of the pandemic and its dependence on regional conditions might supply information to support the implementation of mitigation and suppression strategies. To facilitate research in this direction on the example of the United States, we present a machine-readable dataset that aggregates relevant data from governmental, journalistic, and academic sources on the U.S. county level. In addition to county-level time-series data from the JHU CSSE COVID-19 Dashboard, our dataset contains more than 300 variables that summarize population estimates, demographics, ethnicity, housing, education, employment and income, climate, transit scores, and healthcare system-related metrics. Furthermore, we present aggregated out-of-home activity information for various points of interest for each county, including grocery stores and hospitals, summarizing data from SafeGraph and Google mobility reports. We compile information from IHME, state and county-level government, and newspapers for dates of the enactment and reversal of non-pharmaceutical interventions. By collecting these data, as well as providing tools to read them, we hope to accelerate research that investigates how the disease spreads and why spread may be different across regions. Our dataset and associated code are available at github.com/JieYingWu/COVID-19_US_County-level_Summaries.

cs.CY↗

Leveraging Vision and Kinematics Data to Improve Realism of Biomechanic Soft-tissue Simulation for Robotic Surgery

Purpose Surgical simulations play an increasingly important role in surgeon education and developing algorithms that enable robots to perform surgical subtasks. To model anatomy, Finite Element Method (FEM) simulations have been held as the gold standard for calculating accurate soft-tissue deformation. Unfortunately, their accuracy is highly dependent on the simulation parameters, which can be difficult to obtain. Methods In this work, we investigate how live data acquired during any robotic endoscopic surgical procedure may be used to correct for inaccurate FEM simulation results. Since FEMs are calculated from initial parameters and cannot directly incorporate observations, we propose to add a correction factor that accounts for the discrepancy between simulation and observations. We train a network to predict this correction factor. Results To evaluate our method, we use an open-source da Vinci Surgical System to probe a soft-tissue phantom and replay the interaction in simulation. We train the network to correct for the difference between the predicted mesh position and the measured point cloud. This results in 15-30% improvement in the mean distance, demonstrating the effectiveness of our approach across a large range of simulation parameters. Conclusion We show a first step towards a framework that synergistically combines the benefits of model-based simulation and real-time observations. It corrects discrepancies between simulation and the scene that results from inaccurate modeling parameters. This can provide a more accurate simulation environment for surgeons and better data with which to train algorithms.

cs.RO↗

LumiPath -- Towards Real-time Physically-based Rendering on Embedded Devices

With the increasing computational power of today's workstations, real-time physically-based rendering is within reach, rapidly gaining attention across a variety of domains. These have expeditiously applied to medicine, where it is a powerful tool for intuitive 3D data visualization. Embedded devices such as optical see-through head-mounted displays (OST HMDs) have been a trend for medical augmented reality. However, leveraging the obvious benefits of physically-based rendering remains challenging on these devices because of limited computational power, memory usage, and power consumption. We navigate the compromise between device limitations and image quality to achieve reasonable rendering results by introducing a novel light field that can be sampled in real-time on embedded devices. We demonstrate its applications in medicine and discuss limitations of the proposed method. An open-source version of this project is available at https://github.com/lorafib/LumiPath which provides full insight on implementation and exemplary demonstrational material.

cs.CV↗