arXiv Science⌕ Search

arXiv subjects

Jie Ying Wu

Publications and source records attributed to Jie Ying Wu.

At least 19 recordsLinked to original sources

Dynamic Model Identification and Gravity Compensation for the dVRK-Si Patient Side Manipulator

The da Vinci Research Kit (dVRK) has been widely used for research in robot-assisted surgery over the past decade, and its latest generation, the dVRK-Si was made publicly available in 2025. This manuscript presents the first complete kinematic and dynamic modeling framework for the dVRK-Si Patient-Side Manipulator (PSM), whose redesigned mechanism differs substantially from that of the first-generation dVRK and therefore requires a new formulation to accurately capture gravitational effects and improve overall control performance. We first develop a modified DH kinematic model that represents the dVRK-Si PSM's redesigned mechanism. The equations of motion are then derived using the Euler-Lagrange formulation, and the inverse dynamics are expressed in a linear-in-parameters regressor form. The dynamic parameters are identified from data collected along a periodic excitation trajectory optimized for numerical conditioning and estimated by convex optimization subject to the physical feasibility constraints. The identified model is integrated into the dVRK control stack to enable real-time gravity compensation and computed-torque feedforward control. Experiments on a physical dVRK-Si demonstrate that the gravity compensation reduces steady-state joint errors by up to 84% and decreases end-effector tip drift during static holds from 4.2 mm to 0.7 mm. Computed-torque feedforward control further improves transient and trajectory-tracking accuracy. During sinusoidal trajectory tracking, computed-torque feedforward reduces position errors by 35\% versus gravity-only feedforward and by 40% versus PID-only. The proposed pipeline could support reliable control, high-fidelity simulation, and learning-based automation on the dVRK-Si.

cs.RO↗

Object-Centered Reconstruction for Vision-Based 3D Force Estimation

Excessive force may damage tissue and increase the risk of anastomotic leakage in robotic colorectal surgery. Although the da Vinci 5 provides force sensing, this capability is unavailable on earlier da Vinci systems and many other surgical robotic platforms. In this work, we present a vision-based pipeline for estimating 3D interaction forces from soft-tissue deformation in stereo endoscopic video. We dynamically reconstruct the tissue point cloud in an object-centered coordinate frame, track tissue points with geometric constraints, and predict the 3D force vector with a neural network. We progressively evaluate the pipeline on rubber-glove phantoms, ex vivo porcine colons, and in vivo colorectal surgical video sequences. Under varying tissue orientations and positions within the endoscopic view, as well as different camera viewpoints, the proposed method achieves average root mean square error (RMSEs) of 0.77 N and 1.30 N on the phantom and porcine colon, respectively. Compared with the camera-frame representation, the object-centered representation reduces average RMSE by 51.3% and 56.7%, while geometry-constrained tracking reduces RMSE by 19.8% and 25.3% compared with CoTracker. We further qualitatively demonstrate the feasibility of vision-based force estimation on an in vivo colorectal surgical sequence, as a step toward clinical translation of vision-based, sensorless force estimation.

cs.RO↗

RAUL: Reference-Assisted Ureteroscopy Localization for Skill Assessment

Objective: Incomplete navigation of anatomy during ureteroscopic kidney stone surgeries can contribute to repeat interventions. While skilled surgeons have lower reintervention rates, there are no objective metrics to quantify scope-navigation performance to evaluate when a trainee becomes skilled. This work aims to recover ureteroscope trajectories from endoscopic video and derive navigation metrics to quantify differences in skill. Methods: We propose RAUL, a reference-assisted reconstruction framework for recovering ureteroscope trajectories from ureteroscope videos only in phantoms. For each phantom, we use a slow, high-quality reference exploration video to generate a reference reconstruction. We localize subsequent exploration videos against this reference. We evaluate localization accuracy against electromagnetically tracked scope pose. We compute navigation metrics from phantom exploration trajectories to compare surgical residents across experience levels. Results: The proposed reference-assisted framework achieves a mean translation root mean square error of $0.5 \pm 0.1$ mm across 9 phantoms. Compared to standard Structure-from-Motion (SfM), the proposed pipeline increases frame-wise localization coverage from $50.5 \pm 14.9\%$ to $86.1 \pm 7.2\%$ of all video frames. The reconstructed trajectories revealed significant differences between high- and low-experience trainees in established navigation metrics. Conclusion: RAUL enables substantially more complete recovery of ureteroscope trajectories from videos compared to standard SfM pipelines, enabling trajectory-based skill assessment without additional tracking equipment. Significance: To the best of our knowledge, this is the first use of video-only recovery of ureteroscope trajectories without external tracking sensors for skill assessment, supporting scalable automated assessment of ureteroscopy navigation skill.

cs.CV↗

Differentiable Mesh State Estimation via Factor Graph Inference for Deformable Object Reconstruction

Estimating deformable object states remains a fundamental challenge in robotics and simulation. We propose a novel factor graph-based framework for probabilistic mesh state estimation of deformable objects. The method directly updates a tetrahedral mesh, a rich and physically-grounded representation of an environment, by combining physics priors, noisy sensor measurements, and temporal smoothness constraints within a unified probabilistic formulation. The estimation problem is posed as a nonlinear least-squares optimization and solved using Levenberg-Marquardt. Ex vivo central-airway obstruction experiments and simulations on deforming cube models demonstrate reliable and accurate reconstruction under both rigid motion and deformation, highlighting the potential of this probabilistic approach for principled, measurement-driven mesh state estimation in deformable object reconstruction.

cs.RO↗

DART: Depth-as-Target Pretraining for Surgical Vision Foundation Models

Vision foundation models (VFMs) are valuable in data-scarce domains such as surgery, where a single pretrained backbone can provide rich representations for many downstream tasks. Yet the dominant self-supervised pretraining paradigm uses only RGB images, leaving readily available complementary signals, such as depth maps, unused. This is a particular missed opportunity in surgery, where natural-image VFMs transfer poorly while the scene geometry is rich and informative. With strong off-the-shelf models now able to produce pseudo-labeled dense depth for any image corpus, we hypothesize that such signals can be folded into pretraining to learn better representations. We present DART, an RGB-D pretraining recipe that builds on DINOv2 with a simple modification: a pixel-space depth reconstruction objective applied to masked iBOT patches, supervised by pseudo-labeled depth. Depth is used only during pretraining, so fine-tuning and inference remain RGB-only. We find that this pixel-level reconstruction head improves representation quality rather than disrupting it. We further show that depth, which encodes scene geometry, is more effective as a target than alternative dense signals such as Canny edges, confirming that the gains stem from depth rather than added supervision alone. Across eight surgical benchmarks spanning segmentation, depth estimation, and image-level recognition, DART outperforms both natural-image and in-domain baselines, including a vanilla DINOv2 trained on identical data, improving dense prediction while also strengthening image-level understanding. More broadly, DART shows that freely available geometric pseudo-labels can strengthen foundation model pretraining without extra labels or added inference cost, pointing toward stronger backbones for surgery.

cs.CV↗

Transferable Tool-Tissue Contact Detection from Stereo Depth in Robot-Assisted Surgery

Reliable tool--tissue contact detection can support interaction-aware control and downstream force estimation in robot-assisted surgery. Most existing methods learn a contact classifier from RGB appearance, which is hard to generalize. In this work, we use the depth image generated from a stereo pair to give more information about tool--tissue contact. For each depth frame, we localize a spatially supported minimum-distance patch around the tool boundary and reduce it to a single scalar, $-\log_{10}|d|$; this signal rises and falls in step with ground-truth contact. We formalize this observation with a fully supervised two-state hidden Markov model. We fit this model as a six-fold leave-one-session-out (LOSO) ensemble on six palpation sessions against a single silicone cup-like phantom, with the decision threshold selected from the pooled out-of-fold predictions. It is evaluated on four held-out sessions of three categories: 1. same task on same phantom; 2. same task on different phantom; 3. different task on different phantom. This model reaches held-out macro F1 $0.927$ and AUPRC $0.980$. We further compare against a reproduction of an RGB-based contact classifier from prior work. This RGB-based model achieves high performance on the first category (F1 $0.965$), but substantially lower performance on the other two, resulting in macro F1 $0.320$ across all four sessions. These results indicate that the tool--tissue distance is a strong, transferable cue for contact detection in robot-assisted surgery.

cs.RO↗

Toward surface-based registration of a virtual preoperative cutting guide onto the mandible for reconstruction surgery

Mandibular reconstruction restores facial continuity and oral function after segmental resection. Patient-specific cutting guides transfer a computed tomography (CT)-based plan to the operating room with three-dimensional information, but printed guides add cost and lead time, cannot adapt after fabrication, and may interrupt surgery if sterility is lost. We investigate a markerless augmented reality (AR) alternative that registers a virtual cutting guide to the exposed mandible from surface geometry. The method extends surface-based registration for the transoral setting, where teeth form the most distinctive visible surface. After camera calibration, a HoloLens 2 time-of-flight camera captures a partial intraoperative point cloud. The user supplies a rough head-based alignment only to crop the region of interest. A teeth-weighted global stage computes correspondences and solves a truncated least-squares rigid alignment. An asymmetric point-to-plane iterative closest point (ICP) stage refines the complete CT mandible against the partial depth cloud target. The guide-to-mandible transform places the guide in the HoloLens world frame, while pose updates and interpolation follow target motion. We define a blinded phantom protocol with 30 target registration error (TRE) points under full, intermediate, and teeth-only exposure, plus a motion-to-display latency test. Our median TRE is 4.05, 6.10, and 7.10 mm respectively, and median latency is 0.805 s. These values support the feasibility of using AR to replace physical prints. The workflow removes mounted fiducials and manual landmark selection and provides a testable path toward transoral cutting guidance.

cs.CV↗

On the Role of Depth in Surgical Vision Foundation Models: An Empirical Study of RGB-D Pre-training

Vision foundation models (VFMs) have emerged as powerful tools for surgical scene understanding. However, current approaches predominantly rely on unimodal RGB pre-training, overlooking the complex 3D geometry inherent to surgical environments. Although several architectures support multimodal or geometry-aware inputs in general computer vision, the benefits of incorporating depth information in surgical settings remain underexplored. We conduct a large-scale empirical study comparing eight ViT-based VFMs that differ in pre-training domain, learning objective, and input modality (RGB vs. RGB-D). For pre-training, we use a curated dataset of 1.4 million robotic surgical images paired with depth maps generated from an off-the-shelf network. We evaluate these models under both frozen-backbone and end-to-end fine-tuning protocols across eight surgical datasets spanning object detection, segmentation, depth estimation, and pose estimation. Our experiments yield several consistent findings. Models incorporating explicit geometric tokenization, such as MultiMAE, substantially outperform unimodal baselines across all tasks. Notably, geometric-aware pre-training enables remarkable data efficiency: models fine-tuned on just 25% of labeled data consistently surpass RGB-only models trained on the full dataset. Importantly, these gains require no architectural or runtime changes at inference; depth is used only during pre-training, making adoption straightforward. These findings suggest that multimodal pre-training offers a viable path towards building more capable surgical vision systems.

cs.CV↗

Marker-free deformable registration and fusion for augmented reality-guided positive margin localization during tumor resection surgery

Positive margins in head and neck oncologic surgery require mapping specimen-side pathology findings to the patient resection bed. This is challenging because pathologists identify the positive margin on slices of the resected, deformed specimen, while surgeons must relocate the corresponding site on the resection bed using only verbal descriptions and no visual guidance. We present a marker-free augmented reality (AR) workflow for mapping a margin label from a three-dimensional specimen scan to the resection bed. The method combines contour-constrained deformation, residual alignment to a depth scan, surface-based fusion to a head-mounted display, and target projection onto the reconstructed bed. Bead-suture correspondences estimate specimen deformation, whereas patient-to-display fusion does not require external fiducial markers. Following formative experiments, five residents and surgeons performed cadaveric cheek and scalp re-resection tasks under verbal guidance, verbal guidance with specimen examination, and AR guidance. Deformation target errors were $7.63 \pm 3.74$ mm for the cheek and $3.72 \pm 1.02$ mm for the scalp; residual specimen-to-bed distances were $2.43 \pm 2.15$ mm and $2.19 \pm 1.06$ mm, respectively. Fusion error did not differ significantly between marker-free and marker-based methods on either cadaver; overall marker-free fusion error was $2.15 \pm 0.87$ mm. End-to-end margin localization error decreased from $21.40 \pm 3.84$ mm with verbal guidance and $16.09 \pm 4.30$ mm with specimen examination to $6.19 \pm 1.79$ mm with AR guidance ($p < 0.001$). Online fusion required $5.23 \pm 0.34$ s. These results demonstrate effective marker-free AR guidance for positive-margin localization and support more precise tumor resection.

cs.CV↗

Contour-Constrained Deformable Registration with Parameter Characterization for Head and Neck Surgical Guidance

With 890,000 annual new cases globally, head and neck squamous cell carcinoma has one of the highest recurrence rates among solid malignancies. Although frozen section analysis is the standard of care for intraoperative margin assessment, accurately relocating detected positive margins on the resection bed remains challenging due to imprecise alignment between resected specimens and their resection bed, compounded by post-resection mucosal tissue shrinkage. We present a biomechanics-driven deformable registration framework that corrects post-resection tissue deformation to provide intraoperative guidance. Our approach registers 3D specimen meshes to intraoperative resection bed point clouds using a deformable registration approach based on regularized Kelvinlet basis functions. The registration matches surface point clouds, fiducial landmarks, and boundary contour constraints that directly penalize perpendicular distance-to-agreement between specimen and resection bed boundaries. Across nine specimens from skin, buccal mucosa, and tongue sites, the overall mean target registration error was $11.11 \pm 4.07$ mm using rigid registration, which decreased to $8.20 \pm 2.68$ mm (26.19\% reduction) using deformable registration without contour constraint. The proposed contour-constrained deformable registration further reduced the error to $5.62 \pm 2.28$ mm, a 49.41\% reduction relative to rigid registration. We observed the largest reduction in the most clinically challenging tongue specimens. We also performed a systematic two-stage parameter search to characterize the relative importance of surface alignment, fiducial correspondences, contour constraint, and strain energy regularization. This search revealed that contour weighting dominates registration accuracy for tissue types with large lateral deformation, while the algorithm operates over a broad range of parameter combinations.

eess.IV↗

All-in-One Augmented Reality Guided Head and Neck Tumor Resection

Positive margins are common in head and neck squamous cell carcinoma, yet intraoperative re-resection is often imprecise because margin locations are typically communicated verbally from pathology. We present an all-in-one augmented reality (AR) system that relocalizes positive margins from a resected specimen to the resection bed and visualizes them in situ using HoloLens 2 depth sensing and fully automated markerless surface registration. In a silicone phantom study with six medical trainees, markerless registration achieved target registration errors comparable to a marker-based baseline (median 1.8 mm vs. 1.7 mm; maximum < 4 mm). In a margin relocalization task, AR guidance reduced error from verbal guidance (median 14.2 mm) to a few millimeters (median 3.2 mm), with all AR localizations within 5 mm error. These results support the feasibility of markerless AR margin guidance for more precise intraoperative re-excision.

cs.CV↗

Markerless Augmented Reality Registration for Surgical Guidance: A Multi-Anatomy Clinical Accuracy Study

Purpose: In this paper, we develop and clinically evaluate a depth-only, markerless augmented reality (AR) registration pipeline on a head-mounted display, and assess accuracy across small or low-curvature anatomies in real-life operative settings. Methods: On HoloLens 2, we align Articulated HAnd Tracking (AHAT) depth to Computed Tomography (CT)-derived skin meshes via (i) depth-bias correction, (ii) brief human-in-the-loop initialization, (iii) global and local registration. We validated the surface-tracing error metric by comparing "skin-to-bone" relative distances to CT ground truth on leg and foot models, using an AR-tracked tool. We then performed seven intraoperative target trials (feet x2, ear x3, leg x2) during the initial stage of fibula free-flap harvest and mandibular reconstruction surgery, and collected 500+ data per trial. Results: Preclinical validation showed tight agreement between AR-traced and CT distances (leg: median |Delta d| 0.78 mm, RMSE 0.97 mm; feet: 0.80 mm, 1.20 mm). Clinically, per-point error had a median of 3.9 mm. Median errors by anatomy were 3.2 mm (feet), 4.3 mm (ear), and 5.3 mm (lower leg), with 5 mm coverage 92-95%, 84-90%, and 72-86%, respectively. Feet vs. lower leg differed significantly (Delta median ~1.1 mm; p < 0.001). Conclusion: A depth-only, markerless AR pipeline on HMDs achieved ~3-4 mm median error across feet, ear, and lower leg in live surgical settings without fiducials, approaching typical clinical error thresholds for moderate-risk tasks. Human-guided initialization plus global-to-local registration enabled accurate alignment on small or low-curvature targets, improving the clinical readiness of markerless AR guidance.

cs.CV↗

Intuitive Surgical SurgToolLoc and SurgVU Challenges Results: 2022-2025

Robotic assisted (RA) surgery promises to transform surgical intervention. Intuitive Surgical is committed to fostering these changes and the machine learning models and algorithms that will enable them. With these goals in mind we have invited the surgical data science community to participate in a yearly competition hosted through the Medical Imaging Computing and Computer Assisted Interventions (MICCAI) conference. With varying changes from year to year, we have challenged the community to solve difficult machine learning problems in the context of advanced RA applications. Here we document the results of these challenges, focusing on surgical tool localization (SurgToolLoc) and surgical visual understanding (SurgVU). The publicly released dataset that accompanies these challenges is detailed in a separate paper arXiv:2501.09209 [1].

cs.CV↗

SCARED-C: Corrected Camera Poses for Endoscopic Depth Estimation

The SCARED dataset is a widely used benchmark for endoscopic depth estimation, offering ground-truth 3D reconstructions captured with a structured light sensor. However, the depth maps for non-keyframe images rely on robot kinematics that introduce substantial pose errors, limiting the reliably labeled portion of the dataset to 35 keyframes. We present SCARED-C, a corrected version of the SCARED dataset that expands the number of reliable RGB-D pairs from 35 to 17,135. Our pipeline applies COLMAP, a Structure-from-Motion system, to re-estimate camera poses for all frames, followed by a scale recovery step that aligns the resulting reconstructions to metric space using the ground-truth keyframe depth maps. We validate the corrected poses through (1) stereo disparity evaluation and (2) monocular depth estimation experiments. The corrected dataset and code are publicly released to the community.

cs.CV↗

SurgFormer: Scalable Learning of Organ Deformation with Resection Support and Real-Time Inference

We introduce SurgFormer, a multiresolution gated transformer for data driven soft tissue simulation on volumetric meshes. High fidelity biomechanical solvers are often too costly for interactive use, so we train SurgFormer on solver generated data to predict nodewise displacement fields at near real time rates. SurgFormer builds a fixed mesh hierarchy and applies repeated multibranch blocks that combine local message passing, coarse global self attention, and pointwise feedforward updates, fused by learned per node, per channel gates to adaptively integrate local and long range information while remaining scalable on large meshes. For cut conditioned simulation, resection information is encoded as a learned cut embedding and provided as an additional input, enabling a unified model for both standard deformation prediction and topology altering cases. We also introduce two surgical simulation datasets generated under a unified protocol with XFEM based supervision: a cholecystectomy resection dataset and an appendectomy manipulation and resection dataset with cut and uncut cases. To our knowledge, this is the first learned volumetric surrogate setting to study XFEM supervised cut conditioned deformation within the same volumetric pipeline as standard deformation prediction. Across diverse baselines, SurgFormer achieves strong accuracy with favorable efficiency, making it a practical backbone for both tasks. {Code, data, and project page: \href{https://mint-vu.github.io/SurgFormer/}{available here}}

cs.CV↗

Automated Assessment of Kidney Ureteroscopy Exploration for Training

Purpose: Kidney ureteroscopic navigation is challenging with a steep learning curve. However, current clinical training has major deficiencies, as it requires one-on-one feedback from experts and occurs in the operating room (OR). Therefore, there is a need for a phantom training system with automated feedback to greatly \revision{expand} training opportunities. Methods: We propose a novel, purely ureteroscope video-based scope localization framework that automatically identifies calyces missed by the trainee in a phantom kidney exploration. We use a slow, thorough, prior exploration video of the kidney to generate a reference reconstruction. Then, this reference reconstruction can be used to localize any exploration video of the same phantom. Results: In 15 exploration videos, a total of 69 out of 74 calyces were correctly classified. We achieve < 4mm camera pose localization error. Given the reference reconstruction, the system takes 10 minutes to generate the results for a typical exploration (1-2 minute long). Conclusion: We demonstrate a novel camera localization framework that can provide accurate and automatic feedback for kidney phantom explorations. We show its ability as a valid tool that enables out-of-OR training without requiring supervision from an expert.

eess.IV↗

Neural-Augmented Kelvinlet for Real-Time Soft Tissue Deformation Modeling

Accurate and efficient modeling of soft-tissue interactions is fundamental for advancing surgical simulation, surgical robotics, and model-based surgical automation. To achieve real-time latency, classical Finite Element Method (FEM) solvers are often replaced with neural approximations; however, naively training such models in a fully data-driven manner without incorporating physical priors frequently leads to poor generalization and physically implausible predictions. We present a novel physics-informed neural simulation framework that enables real-time prediction of soft-tissue deformations under complex single- and multi-grasper interactions. Our approach integrates Kelvinlet-based analytical priors with large-scale FEM data, capturing both linear and nonlinear tissue responses. This hybrid design improves predictive accuracy and physical plausibility across diverse neural architectures while maintaining the low-latency performance required for interactive applications. We validate our method on challenging surgical manipulation tasks involving standard laparoscopic grasping tools, demonstrating substantial improvements in deformation fidelity and temporal stability over existing baselines. These results establish Kelvinlet-augmented learning as a principled and computationally efficient paradigm for real-time, physics-aware soft-tissue simulation in surgical AI.

cs.GR↗

PERSEUS: Perception with Semantic Endoscopic Understanding and SLAM

Purpose: Natural orifice surgeries minimize the need for incisions and reduce the recovery time compared to open surgery; however, they require a higher level of expertise due to visualization and orientation challenges. We propose a perception pipeline for these surgeries that allows semantic scene understanding. Methods: We bring learning-based segmentation, depth estimation, and 3D reconstruction modules together to create real-time segmented maps of the surgical scenes. Additionally, we use registration with robot poses to solve the scale ambiguity of mapping from monocular images, and allow the use of semantically informed real-time reconstructions in robotic surgeries. Results: We achieve sub-milimeter reconstruction accuracy based on average one-sided Chamfer distances, average pose registration RMSE of 0.9 mm, and an estimated scale within 2% of ground truth. Conclusion: We present a modular perception pipeline, integrating semantic segmentation with real-time monocular SLAM for natural orifice surgeries. This pipeline offers a promising solution for scene understanding that can facilitate automation or surgeon guidance.

cs.RO↗