arXiv ScienceSearch

arXiv subjects

F. Ballester

Publications and source records attributed to F. Ballester.

At least 19 recordsLinked to original sources

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

physics.ins-det

Revealing magnetism in the distorted kagome $R$Ti$_3$Bi$_4$ ($R$ = Nd, Sm, Gd) via ARPES and XMCD

Kagome materials are known for hosting emergent quantum phenomena driven by the interaction between different lattice, charge and spin orders. Here, we present a detailed angle resolved photoemission (ARPES), density functional theory (DFT) and x-ray magnetic circular dichroism (XMCD) study of the electronic and magnetic structure of $R$Ti$_3$Bi$_4$ ($R$ = Nd, Sm, Gd). ARPES and DFT demonstrate that the bulk electronic band structure is dominated by the hybridization of the Ti bands, and the weak electron-like pocket at $\Gamma$ is identified as a surface state. The isotropic XAS profile of the $M_{4,5}$-edge of the rare earth is consistent with the presence of $R^{3+}$ oxidation state. Using the XMCD sum rules, backed by the atomic multiplet theory calculations, we obtain the spin and orbital magnetic moments. The Ti $L_{2,3}$-edge XMCD reveals the presence of a small magnetic moment in GdTi$_3$Bi$_4$, presumably driven by the proximity of the {Ti} kagome layers to the $zigzag$ chains of Gd, while the total magnetic moment of Gd is shared by the $f$ and $d$ electrons. Our combined XMCD, ARPES and DFT study brings an important piece of information to understand the spin flip transitions and anomalous Hall effect observed in the $R$Ti$_3$Bi$_4$ kagome metals.

cond-mat.mtrl-sci

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the \bbnonu decay using a high-pressure \Xe{136} electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal \Rn{222} activity is found to be (0.95$\pm$0.04(stat)$\pm$0.09(sys)) Bq/m$^3$, while no traces of \Rn{220} have been observed. Most of the \Rn{222} progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced \Bi{214} of (0.97$\pm$0.05(stat)$\pm$0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the \bbnonu region of interest is evaluated as (7.3$\pm$1.5(stat)$\pm$0.8(sys))$\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) after selection of the fully contained events. This background index is reduced to $\sim$4$\times10^{-5}$ counts/(keV$\cdot$kg$\cdot$yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.

hep-ex

Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector

The NEXT-DEMO++ detector, a high-pressure xenon gas time projection chamber serving as a prototype for the NEXT-100 experiment, was used to measure the electroluminescence (EL) yield as a function of reduced electric field ($E/p$) across pressures from 2.0 to 9.4 bar, utilizing the 41.5 keV de-excitation peak of $^{83m}$Kr. These measurements were made to examine the pressure dependence of the slope of the reduced EL yield $Y/p$, which has shown inconsistencies in the literature. The reduced yield was fitted with a linear model, revealing a modest ($\sim$5%) change in slope, beginning around 5 bar and increasing with pressure up to 9.4 bar.

physics.ins-det

Flat band driven competing charge and spin instabilities in the altermagnet CrSb

The confinement of electronic wavefunctions in momentum space can give rise to flat electronic bands, where the quenching of kinetic energy enhances the density of states and amplifies interaction effects. Such conditions are fertile ground for emergent quantum phases, as spin, charge and lattice degrees of freedom become strongly entangled. In these regimes, subtle competitions between intertwined order parameters often dictate the macroscopic ground state, producing complex and sometimes unexpected collective behavior. Here we show that the altermagnet CrSb provides a realization of this scenario, and uncover short-range charge-order fluctuations at the M point of the Brillouin zone, q*=(1/2 0), persisting above the Neel temperature (TN). Remarkably, these fluctuations collapse upon entering the magnetically ordered phase, revealing a direct and robust competition between charge and spin order. At TN, the phonon dispersion at q* develops a pronounced Kohn-like anomaly, signaling strong electron-phonon coupling in the vicinity of the magnetic transition. Below TN, exchange striction dramatically renormalizes the associated soft phonon mode by approximately ~6 meV, the largest spin-phonon coupling ever reported. First-principles calculations attribute this behavior to a strong coupling between nearly dispersionless electronic states and a phonon branch that appears unstable at the harmonic level only when no magnetic order is considered, revealing the large sensitivity of the lattice to magnetic symmetry breaking. The competition between charge and spin order parameters, amplified by flat-band physics, drives the observed phonon anomaly and its abrupt reconstruction at TN. With its chemically simple structure and symmetry-protected altermagnetic state, CrSb emerges as a model platform to explore how flat electronic bands mediate giant spin-phonon coupling and competing broken symmetries.

cond-mat.str-el

Demonstration of Sub-Percent Energy Resolution in the NEXT-100 Detector

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ($\beta\beta 0\nu$) of Xe-136. The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ($Q_{\beta\beta}$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a Th-228 source, demonstrating linear response and an energy resolution of $(0.90 \pm 0.02)$% FWHM at the Tl-208 photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $R(Q_{\beta\beta})$ = $(0.93 \pm 0.02)$% FWHM, confirming the detector's capability for precision energy measurement in the search for $\beta\beta 0\nu$.

physics.ins-det

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $^{136}$Xe using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterr\'aneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83m}$Kr decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83m}$Kr point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta\beta}$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

hep-ex

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of $^{136}$Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ($\leq 1\%$ FWHM at the $Q_{\beta\beta}$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterr\'aneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $\sim$4 bar and drift fields of 74 V/cm and 118 V/cm, respectively. Alpha decays from the $^{222}$Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

physics.ins-det

High Voltage Delivery and Distribution for the NEXT-100 Time Projection Chamber

A critical element in the realization of large liquid and gas time projection chambers (TPCs) is the delivery and distribution of high voltages into and around the detector. Such experiments require of order tens of kilovolts to enable electron drift over meter-scale distances. This paper describes the design and operation of the cathode feedthrough and high voltage distribution through the field cage of the NEXT-100 experiment, an underground TPC that will search for neutrinoless double beta decay $0\nu\beta\beta$. The feedthrough has been demonstrated to hold pressures up to 20~bar and sustain voltages as high as -65~kV, and the TPC is operating stably at its design high voltages. The system has been realized within the constraints of a stringent radiopurity budget and is now being used to execute a suite of sensitive double beta decay analyses.

physics.ins-det

Performance of an Optical TPC Geant4 Simulation with Opticks GPU-Accelerated Photon Propagation

We investigate the performance of Opticks, a NVIDIA OptiX API 7.5 GPU-accelerated photon propagation tool compared with a single-threaded Geant4 simulation. We compare the simulations using an improved model of the NEXT-CRAB-0 gaseous time projection chamber. Performance results suggest that Opticks improves simulation speeds by between 58.47+/-0.02 and 181.39+/-0.28 times relative to a CPU-only Geant4 simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between Opticks and Geant4.

physics.ins-det

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle $\cos\theta$ among the two decay electrons, and the electron energy spectra, $T_1$ and $T_2$. In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{\cos\theta}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

hep-ex

Characterisation of exposure to non-ionising electromagnetic fields in the Spanish INMA birth cohort: Study protocol

Analysis of the association between exposure to electromagnetic fields of non-ionising radiation (EMF-NIR) and health in children and adolescents is hindered by the limited availability of data, mainly due to the difficulties on the exposure assessment. This study protocol describes the methodologies used for characterising exposure of children to EMF-NIR in the INMA (INfancia y Medio Ambiente- Environment and Childhood) Project, a prospective cohort study. Indirect (proximity to emission sources, questionnaires on sources use and geospatial propagation models) and direct methods (spot and fixed longer-term measurements and personal measurements) were conducted in order to assess exposure levels of study participants aged between 7 and 18 years old. The methodology used varies depending on the frequency of the EMF-NIR and the environment (homes, schools and parks). Questionnaires assessed the use of sources contributing both to Extremely Low Frequency (ELF) and Radiofrequency (RF) exposure levels. Geospatial propagation models (NISMap) are implemented and validated for environmental outdoor sources of RFs using spot measurements. Spot and fixed longer-term ELF and RF measurements were done in the environments where children spend most of the time. Moreover, personal measurements were taken in order to assess individual exposure to RF. The exposure data are used to explore their relationships with proximity and/or use of EMF-NIR sources.

eess.SP

Evaluation of Coincidence Time Resolution in a liquid xenon detector with silicon photomultipliers

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first prototype optimized to maximize light collection using high-PDE, VUV-sensitive sensors and to minimize time fluctuations. We report a coincidence time resolution of 281 $\pm$ 2 ps FWHM, obtained using a $^{22}$Na calibration source. This result is competitive with the current state-of-the-art PET scanners and represents a significant step forward in the development of liquid xenon as a viable alternative to conventional scintillators in PET technology.

physics.ins-det

Measurement of Energy Resolution with the NEXT-White Silicon Photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}\text{Kr}$ data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 $\pm$ 0.6) $\%$, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.

hep-ex

Fluorescence Imaging of Individual Ions and Molecules in Pressurized Noble Gases for Barium Tagging in $^{136}$Xe

The imaging of individual Ba$^{2+}$ ions in high pressure xenon gas is one possible way to attain background-free sensitivity to neutrinoless double beta decay and hence establish the Majorana nature of the neutrino. In this paper we demonstrate selective single Ba$^{2+}$ ion imaging inside a high-pressure xenon gas environment. Ba$^{2+}$ ions chelated with molecular chemosensors are resolved at the gas-solid interface using a diffraction-limited imaging system with scan area of 1$\times$1~cm$^2$ located inside 10~bar of xenon gas. This new form of microscopy represents an important enabling step in the development of barium tagging for neutrinoless double beta decay searches in $^{136}$Xe, as well as a new tool for studying the photophysics of fluorescent molecules and chemosensors at the solid-gas interface.

physics.ins-det

Demonstration of Event Position Reconstruction based on Diffusion in the NEXT-White Detector

Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from $^{83\mathrm{m}}$Kr calibration electron captures ($E\sim45$keV), the position of origin of low-energy events is determined to $2~$cm precision with bias $< 1$mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E$\geq$1.5MeV), yielding a precision of 3cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q$_{\beta\beta}$ in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.

hep-ex

Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions

NEXT-100 is currently being constructed at the Laboratorio Subterr\'aneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT-100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT-100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. The electrostatic deflection of the mesh is quantified and fit to a first-principles mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.

physics.ins-det

Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT

The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in $^{136}$Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterr\'aneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neutrinoless double beta decay search. The analysis considers the combination of 271.6 days of $^{136}$Xe-enriched data and 208.9 days of $^{136}$Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50$\pm$0.01 kg of $^{136}$Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T$_{1/2}^{0\nu}>5.5\times10^{23}-1.3\times10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.

nucl-ex