arXiv Science⌕ Search

arXiv · 2610.12084

First demonstration of $50\,\mathrm{ps}$ four-dimensional vertex reconstruction with the Timepix4 beam telescope

Abstract

The first demonstration of 4D vertex reconstruction at the $50\,\mathrm{ps}$ scale using a silicon pixel detector is reported. Hadronic interactions are produced by directing a $180\,\mathrm{GeV}/c$ mixed-hadron beam onto a fixed target upstream of the Timepix4 beam telescope at the CERN SPS. The resulting particles are reconstructed using 4D track and vertex fits that include time directly alongside the spatial parameters. The vertex time resolution follows the expected statistical scaling with the number of timing measurements, reaching $54\pm5\,\mathrm{ps}$ for vertices reconstructed from 16 timing-plane clusters. An irreducible component of $29.2\pm0.6\,\mathrm{ps}$ remains in the fitted resolution model, including sizeable contributions from the clock distribution and the time reference system rather than from the combination of the timing measurements. The observed scaling down to $54\,\mathrm{ps}$ without an unforeseen resolution floor above represents a significant experimental step towards precision-timing in future high-pile-up detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David Bacher, Kazu Akiba, Martin van Beuzekom, Victor Coco, Raphael Dumps, Tim Evans, Kevin Heijhoff, Malcolm John, Edgar Lemos Cid, Loris Martinazzoli, Tommaso Pajero, Yutaro Takahashi, Espen de Wit. 2026-10-08. First demonstration of $50\,\mathrm{ps}$ four-dimensional vertex reconstruction with the Timepix4 beam telescope. https://arxiv.org/abs/2610.12084

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Enhanced micrometre spatial resolution and usable photon flux for hybrid pixel detectors via deep-learning-based X-ray localization

Micrometre spatial resolution is achieved for X-rays with the MÖNCH detector, a charge-integrating hybrid pixel detector with a 25 μm pixel pitch, by exploiting charge sharing between neighbouring pixels. The conventional analytical interpolation method, however, relies on a global mapping derived from the charge-sharing statistics and is applicable only to isolated single-photon clusters, which limits both the achievable resolution and the usable photon flux. To overcome these limitations, we trained deep learning models to localize single-photon and pile-up events based on high-fidelity simulation data. For knife-edge measurements at 12 keV and a low occupancy of 0.74% (photons per pixel and frame), where single-photon events dominate, the proposed method reaches a of the edge spread function of 1.36 μm, compared with 1.54 μm for the conventional eta interpolation. We demonstrate experimentally that resolving up to three photons per cluster raises the reconstruction efficiency from 59% to 93% at a 2.4{\times} higher occupancy of 1.81%, while preserving a of 1.39 μm.

physics.ins-det↗

From Tunnel Overburden Reconstruction to Tidal Measurements via atmospheric muon

Muography with scintillator-based detectors enables the investigation of density distributions within large structures. The Hankuk Atmospheric-muon Wide Landscaping (HAWL) project is the first real-time portable muon tomography. It successfully charted the mountainous region of eastern Korea by measuring cosmic-ray muons with a detector operated in a moving vehicle. HAWL achieved a tunnel length accuracy of 6.0 % and an overburden measurement range of 8-400 meter-water-equivalent (m.w.e.). The HAWL upgrade (HAWLU) features a more compact design and enables trajectory reconstruction. Using this upgraded system, we measured tidal water-level variations with meter-scale precision over 31.6 days in the Boryeong Undersea Tunnel. The measured muon rate decreased by $1.72 \pm 0.04$ % per meter of increasing tidal level, while the reconstruction of undersea tunnel scan independently validated the detector performance. These results demonstrate the capabilities of dynamic muography in two approaches, one with a portable detector in motion and the other with a detector measuring a target that changes over time.

physics.ins-det↗

Autocorrelation-based beam shape optimization in scanning electron microscopy

Many automatically focusing algorithms for scanning electron microscopes exist. Typically, these optimize a single derived metric (such as image sharpness) without considering the intrinsic beam shape. We describe an algorithm to automatically focus and stigmate scanning electron microscopes based on the autocorrelation of captured images. In the first part of this work, we develop the theoretical basis of using the autocorrelation to approximate the current beam shape. In the second part, we use this to condition the beam shape on various surfaces, using Bayesian optimization to tune both working distance and, in particular, stigmation. Through a comparison of the full width at half maximum of the autocorrelation arrays before and after optimization and a visual comparison of images taken of the sample surface before and after optimization, we show that the algorithm is able to successfully optimize the scanning parameters. Overall, our algorithm can effectively focus on a variety of topographies at different magnifications.

physics.ins-det↗