arXiv Science⌕ Search

arXiv · 2610.11044

Enhanced micrometre spatial resolution and usable photon flux for hybrid pixel detectors via deep-learning-based X-ray localization

Abstract

Micrometre spatial resolution is achieved for X-rays with the MÖNCH detector, a charge-integrating hybrid pixel detector with a 25 μm pixel pitch, by exploiting charge sharing between neighbouring pixels. The conventional analytical interpolation method, however, relies on a global mapping derived from the charge-sharing statistics and is applicable only to isolated single-photon clusters, which limits both the achievable resolution and the usable photon flux. To overcome these limitations, we trained deep learning models to localize single-photon and pile-up events based on high-fidelity simulation data. For knife-edge measurements at 12 keV and a low occupancy of 0.74% (photons per pixel and frame), where single-photon events dominate, the proposed method reaches a of the edge spread function of 1.36 μm, compared with 1.54 μm for the conventional eta interpolation. We demonstrate experimentally that resolving up to three photons per cluster raises the reconstruction efficiency from 59% to 93% at a 2.4{\times} higher occupancy of 1.81%, while preserving a of 1.39 μm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Xiangyu Xie, Anna Bergamaschi, Martin Brückner, Maria Carulla, Tomáš Celko, Roberto Dinapoli, Simon Ebner, Simone Emiliani, Khalil Daniel Ferjaoui, Erik Lars Fröjdh, Viveka Gautam, Dominic Greiffenberg, Shqipe Hasanaj, Viktoria Hinger, Marius Hürst, Vadym Kedych, Thomas King, Shuqi Li, Carlos Lopez-Cuenca, Leonid Lunin, Federica Marone, Alice Francesca Mazzoleni, Davide Mezza, Scharon Moses, Konstantinos Moustakas, Aldo Mozzanica, Jonathan Franklin Mulvey, Martin Müller, Christian Ruder, Bernd Schmitt, Saverio Silletta, Dhanya Thattil, Jiaguo Zhang. 2026-10-08. Enhanced micrometre spatial resolution and usable photon flux for hybrid pixel detectors via deep-learning-based X-ray localization. https://arxiv.org/abs/2610.11044

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

From Tunnel Overburden Reconstruction to Tidal Measurements via atmospheric muon

Muography with scintillator-based detectors enables the investigation of density distributions within large structures. The Hankuk Atmospheric-muon Wide Landscaping (HAWL) project is the first real-time portable muon tomography. It successfully charted the mountainous region of eastern Korea by measuring cosmic-ray muons with a detector operated in a moving vehicle. HAWL achieved a tunnel length accuracy of 6.0 % and an overburden measurement range of 8-400 meter-water-equivalent (m.w.e.). The HAWL upgrade (HAWLU) features a more compact design and enables trajectory reconstruction. Using this upgraded system, we measured tidal water-level variations with meter-scale precision over 31.6 days in the Boryeong Undersea Tunnel. The measured muon rate decreased by $1.72 \pm 0.04$ % per meter of increasing tidal level, while the reconstruction of undersea tunnel scan independently validated the detector performance. These results demonstrate the capabilities of dynamic muography in two approaches, one with a portable detector in motion and the other with a detector measuring a target that changes over time.

physics.ins-det↗

Autocorrelation-based beam shape optimization in scanning electron microscopy

Many automatically focusing algorithms for scanning electron microscopes exist. Typically, these optimize a single derived metric (such as image sharpness) without considering the intrinsic beam shape. We describe an algorithm to automatically focus and stigmate scanning electron microscopes based on the autocorrelation of captured images. In the first part of this work, we develop the theoretical basis of using the autocorrelation to approximate the current beam shape. In the second part, we use this to condition the beam shape on various surfaces, using Bayesian optimization to tune both working distance and, in particular, stigmation. Through a comparison of the full width at half maximum of the autocorrelation arrays before and after optimization and a visual comparison of images taken of the sample surface before and after optimization, we show that the algorithm is able to successfully optimize the scanning parameters. Overall, our algorithm can effectively focus on a variety of topographies at different magnifications.

physics.ins-det↗

Design Studies Of A Pulsed Quasimonoenergetic 2-keV Neutron Source For Calibration Of Low Threshold Dark Matter Detectors

We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub- GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and subsequently filtered to achieve a monoenergetic spectrum utilizing the antiresonance feature, characterized by a drop in neutron transmission spectra at 2-keV for scandium. The analyses and conclusions presented are primarily based on simulations, as this study represents a critical first step toward the final goal. We address challenges such as unmoderated high-energy neutrons and gamma backgrounds from neutron capture in the moderator materials. Through optimization of the moderator+filter and shielding geometry, we identify a configuration that achieves the target neutron flux at 2 keV while maintaining subdominant rates of background interactions in simulation. Lastly, we outline a future pathway to lower-energy (few eV scale) calibrations using time-of-flight and sub-keV neutrons

physics.ins-det↗