arXiv ScienceSearch

arXiv · 1405.7808

Performance of the LHCb Vertex Locator

Abstract

The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 microns is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 micron for translations in the plane transverse to the beam. A primary vertex resolution of 13 microns in the transverse plane and 71 microns along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 microns is achieved for particles with transverse momentum greater than 1 GeV/c.

Explore related subjects

Keep this discovery

BibTeXRIS

LHCb VELO Group, R. Aaij, A. Affolder, K. Akiba, M. Alexander, S. Ali, R. B. Appleby, M. Artuso, A. Bates, A. Bay, O. Behrendt, J. Benton, M. van Beuzekom, P. M. Bjørnstad, G. Bogdanova, S. Borghi, A. Borgia, T. J. V. Bowcock, J. van den Brand, H. Brown, J. Buytaert, O. Callot, J. Carroll, G. Casse, P. Collins, S. De Capua, M. Doets, S. Donleavy, D. Dossett, R. Dumps, D. Eckstein, L. Eklund, C. Farinelli, S. Farry, M. Ferro-Luzzi, R. Frei, J. Garofoli, M. Gersabeck, T. Gershon, A. Gong, H. Gong, H. Gordon, G. Haefeli, J. Harrison, V. Heijne, K. Hennessy, W. Hulsbergen, T. Huse, D. Hutchcroft, A. Jaeger, P. Jalocha, E. Jans, M. John, J. Keaveney, T. Ketel, M. Korolev, M. Kraan, T. Laštovička, G. Lafferty, T. Latham, G. Lefeuvre, A. Leflat, M. Liles, A. van Lysebetten, G. MacGregor, F. Marinho, R. McNulty, M. Merkin, D. Moran, R. Mountain, I. Mous, J. Mylroie-Smith, M. Needham, N. Nikitin, A. Noor, A. Oblakowska-Mucha, A. Papadelis, M. Pappagallo, C. Parkes, G. D. Patel, B. Rakotomiaramanana, S. Redford, M. Reid, K. Rinnert, E. Rodrigues, A. F. Saavedra, M. Schiller, O. Schneider, T. Shears, R. Silva Coutinho, N. A. Smith, T. Szumlak, C. Thomas, J. van Tilburg, M. Tobin, J. Velthuis, B. Verlaat, S. Viret, V. Volkov, C. Wallace. 2014-05-30. Performance of the LHCb Vertex Locator. https://doi.org/10.1088/1748-0221/9/09/p09007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det