Realistic Detector Geometry Modeling and Its Impact on Event Reconstruction in JUNO

JUNO is designed to determine the neutrino mass ordering with an energy resolution of 3% at 1 MeV. In the real detector, however, deformations of the central stainless-steel structure during installation lead to deviations of the photomultiplier tube (PMT) positions from their design values. Based on the limited survey data of the PMTs and the stainless-steel truss, we perform a correlation analysis of the measured points and propose a method to predict the positions of all PMTs. Using the resulting realistic geometry, we demonstrate that the detector deformation has a negligible effect on the energy reconstruction. In contrast, inaccuracies in the assumed geometry can introduce vertex biases of up to 40 mm. Incorporating the realistic geometry into the calibration-based PMT response model removes this bias and preserves the stability of the reconstruction algorithms.

physics.ins-det

Liquid Handling of the JUNO Experiment

The Filling, Overflow, and Circulation (FOC) system is a critical subsystem of the Jiangmen Underground Neutrino Observatory (JUNO), responsible for the safe handling of the Liquid Scintillator (LS) and water throughout the detector's commissioning and operational lifetime. This paper details the design and operation of the FOC system, which accomplished the filling of the world's largest LS detector--taking 45 days for water (6.4*10^4 m^3) and 200 days for LS (2.3*10^4 m^3). Throughout water filling, the liquid level difference between the Central Detector and Water Pool was rigorously maintained within safety limits. During LS filling, level control achieved +/-2 cm precision with flow regulation within +/-0.5% of setpoints. An automated control system based on Programmable Logic Controllers and the Experimental Physics and Industrial Control System framework ensured reliable operation. The system preserved LS radiopurity, maintaining 222Rn below 1 mBq/m^3 during filling and achieving 238U/232Th concentrations below 10^-16 g/g. The successful commissioning and operation of the FOC system have established it as an indispensable foundation for the stable long-term operation of the JUNO detector.

physics.ins-det

Design and Verification of the JUNO Liquid Filling Control System

Jiangmen Underground Neutrino Observatory (JUNO) is a large-scale neutrino experiment with multiple physics goals including neutrino mass hierarchy, accurate measurement of neutrino oscillation parameters, neutrino detection from supernova, sun, and earth, etc. This paper presents the design, implementation, and verification of a high-reliability automated control system for the liquid Filling, Overflow, and Circulation system in the JUNO experiment. The system is built upon a Programmable Logic Controller architecture, integrated with high-precision sensors and actuators. It implements advanced control strategies, including Proportional-Integral-Derivative regulation, sequential logic, and safety interlocks, to achieve closed-loop control of critical parameters such as flow rate, liquid level, and pressure. Commissioning tests with both pure water and liquid scintillator demonstrate the system's exceptional performance, achieving flow control stability within 0.5% of the setpoint with a rapid stabilization time. The robust design, featuring hardware redundancy and software safeguards, ensures the system meets the stringent requirements for the safe filling and long-term stable operation of JUNO's 20-kiloton central detector and provides a scalable reference for large underground fluid control experiments.

hep-ex

MATHUSLA: An External Long-Lived Particle Detector to Maximize the Discovery Potential of the HL-LHC

We present the current status of the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle (LLP) detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA40 is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate reach of the LHC main detectors. This provides unique sensitivity to many LLP signals that are highly theoretically motivated, due to their connection to the hierarchy problem, the nature of dark matter, and baryogenesis. Data taking is projected to commence with the start of HL-LHC operations. We summarize the new 40m design for the detector that was recently presented in the MATHUSLA Conceptual Design Report, alongside new realistic background and signal simulations that demonstrate high efficiency for the main target LLP signals in a background-free HL-LHC search. We argue that MATHUSLA's uniquely robust expansion of the HL-LHC physics reach is a crucial ingredient in CERN's mission to search for new physics and characterize the Higgs boson with precision.

physics.ins-det

Conceptual Design Report for the MATHUSLA Long-Lived Particle Detector near CMS

We present the Conceptual Design Report (CDR) for the MATHUSLA (MAssive Timing Hodoscope for Ultra-Stable neutraL pArticles) long-lived particle detector at the HL-LHC, covering the design, fabrication and installation at CERN Point 5. MATHUSLA is a 40 m-scale detector with an air-filled decay volume that is instrumented with scintillator tracking detectors, to be located near CMS. Its large size, close proximity to the CMS interaction point and about 100 m of rock shielding from HL-LHC backgrounds allows it to detect LLP production rates and lifetimes that are one to two orders of magnitude beyond the ultimate sensitivity of the HL-LHC main detectors for many highly motivated LLP signals. Data taking is projected to commence with the start of HL-LHC operations. We present a new 40m design for the detector: its individual scintillator bars and wavelength-shifting fibers, their organization into tracking layers, tracking modules, tower modules and the veto detector; define a high-level design for the supporting electronics, DAQ and trigger system, including supplying a hardware trigger signal to CMS to record the LLP production event; outline computing systems, civil engineering and safety considerations; and present preliminary cost estimates and timelines for the project. We also conduct detailed simulation studies of the important cosmic ray and HL-LHC muon backgrounds, implementing full track/vertex reconstruction and background rejection, to ultimately demonstrate high signal efficiency and $\ll 1$ background event in realistic LLP searches for the main physics targets at MATHUSLA. This sensitivity is robust with respect to detector design or background simulation details. Appendices provide various supplemental information.

physics.ins-det

Development of the strip LGAD detector with double-end readout for future colliders

The Low-Gain Avalanche Diode (LGAD) is a new silicon detector and holds wide application prospects in particle physics experiments due to its excellent timing resolution. The LGAD with a pixel size of 1.3 mm $\times$ 1.3 mm was used to construct a High Granularity Timing Detector (HGTD) in ATLAS experiments to solve the pile-up problem. Meanwhile, the Circular Electron Positron Collider (CEPC) also proposes detectors using the LGAD. However, pixel LGAD exhibits higher readout electronics density and cost, which somewhat limits the application of LGADs. To decrease the readout electronics density, the Institute of High Energy Physics (IHEP) of the Chinese Academy of Sciences has designed strip LGADs with larger areas. These strip LGADs are all 19 mm in length but with different widths of 1.0 mm, 0.5 mm, and 0.3 mm. This article provides a detailed introduction to the design parameters of these strip LGADs and tests their electrical characteristics, including leakage current, break-down voltage, depletion capacitance, etc. The timing resolution and signal-to-noise ratio of the three strip LGAD sensors were investigated using a beta source test system. The position resolution parallel to the strip direction was tested and analyzed for the first time using a pico-second laser test system. Tests have demonstrated that the timing resolution of strip LGADs can reach about 37.5 ps, and position resolution parallel to the strip direction is better than 1 mm.

physics.ins-det

Dark Count of 20-inch PMTs Generated by Natural Radioactivity

The primary objective of the JUNO experiment is to determine the ordering of neutrino masses using a 20-kton liquid-scintillator detector. The 20-inch photomultiplier tube (PMT) plays a crucial role in achieving excellent energy resolution of at least 3% at 1 MeV. Understanding the characteristics and features of the PMT is vital for comprehending the detector's performance, particularly regarding the occurrence of large pulses in PMT dark counts. This research paper aims to further investigate the origin of these large pulses in the 20-inch PMT dark count rate through measurements and simulations. The findings confirm that the main sources of the large pulses are natural radioactivity and muons striking the PMT glass. By analyzing the PMT dark count rate spectrum, it becomes possible to roughly estimate the radioactivity levels in the surrounding environment.

physics.ins-det

Study on U/Th residual radioactivity in acrylic from surface treatment

Acrylic is widely used as material for the target container in low background experiments due to its high light transparency and low intrinsic radioactivity. However, its surface can be easily contaminated during production, so careful treatment of the surface is essential to avoid direct contamination of the target. The Jiangmen Underground Neutrino Observatory will use about 600~t of acrylic to build the spherical vessel of 35.4~m in diameter for a 20~kt liquid scintillator (LS). Since acrylic will contact the LS directly, the cleanliness of the its surface is quite important for the radiopurity of the LS. A new method for measuring the radioactivity of $^{238}$U and $^{232}$Th in acrylic to sub-ppt ($<10^{-12}$~g/g) was developed, and it is crucial for the acrylic radioactivity screening in this study. We performed many background tests on different surface treatments, and the recommended procedure for the treatment of acrylic to achieve low radioactivity and high light transparency could be applicable to other low background experiments.

physics.ins-det

Study on the linearity of 20" dynode and MCP PMTs

The linearity of charge response is an important feature of photomultiplier tubes (PMT) for physics measurements, especially the newly developed 20" MCP-PMT. In this paper, in addition to the traditional method of double light sources, we applied another relative method of 20" PMT to 3" PMT to measure the linearity of the 20" dynode and MCP PMTs in pulse mode with a waveform digitizer. The measurements show a good linear response of 20" PMTs to 1,000 photoelectrons (p.e.). The correlations of the amplitude, rise-time, fall-time, FWHM, baseline recovery, overshoot, and late-pulse to the output charge of the 20" PMTs derived from the waveform analysis, where the MCP-PMT shows very different features compared to the dynode-PMT in particular.

physics.ins-det

The performance of large-pitch AC-LGAD with different N+ dose

AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP) designed a large-size AC-LGAD with a pitch of 2000~\SI{}{\micro\metre} and AC pad of 1000~\SI{}{\micro\metre}, and explored the effect of N+ layer dose on the spatial resolution and time resolution. The spatial resolution varied from 36~\SI{}{\micro\metre} to 16~\SI{}{\micro\metre} depending on N+ dose for a charge corresponding to about 12 minimum ionizing particles. The jitter component of the time resolution does not change significantly with different N+ doses, and it is about 15-17 ps measured by laser. The AC-LGAD with a low N+ dose has a large attenuation factor and better spatial resolution in the central region between pads. In these specific conditions, large signal attenuation factor and low noise level are beneficial to improve the spatial resolution of the AC-LGAD sensor.

physics.ins-det

Design of the PMT underwater cascade implosion protection system for JUNO

Photomultiplier tubes (PMTs) are widely used underwater in large-scale neutrino experiments. As a hollow glass spherelike structure, implosion is unavoidable during long-term operation under large water pressure. There is a possibility of cascade implosion to neighbor PMTs due to shockwave. Jiangmen Underground Neutrino Observatory designed a protection structure for each 20-inch PMT, consisting of a top cover, a bottom cover, and their connection. This paper introduces the requirement and design of the PMT protection system, including the material selection, investigation of manufacture technology, and prototyping. Optimization and validation by simulation and underwater experiments are also presented.

physics.ins-det

Study of 20-inch PMTs dark count generated large pulses

The main goal of the JUNO experiment is to determine the neutrino mass ordering with a 20\,kt liquid-scintillator detector. The 20-inch PMT is crucial as one of JUNO key instruments to realize an excellent energy resolution of at least 3\,\% at 1\,MeV. The knowledge on PMT's characterisation and feature is critical for detector performance understanding. Large pulses from PMT dark count such as from flasher or others are one of the serious concerns for detector noise control. Focusing on the large pulses from 20-inch PMT dark count, this paper is trying to investigate the causes by measurements with a muon tagging system. It is found that the large pules of 20-inch PMT dark count is contributed mainly from muons hitting the PMT glass. A simulation is also realized and achieved a consistent understanding.

physics.ins-det

Design and testing of LGAD sensor with shallow carbon implantation

The low gain avalanche detectors (LGADs) are thin sensors with fast charge collection which in combination with internal gain deliver an outstanding time resolution of about 30 ps. High collision rates and consequent large particle rates crossing the detectors at the upgraded Large Hadron Collider (LHC) in 2028 will lead to radiation damage and deteriorated performance of the LGADs. The main consequence of radiation damage is loss of gain layer doping (acceptor removal) which requires an increase of bias voltage to compensate for the loss of charge collection efficiency and consequently time resolution. The Institute of High Energy Physics (IHEP), Chinese Academy of Sciences (CAS) has developed a process based on the Institute of Microelectronics (IME), CAS capability to enrich the gain layer with carbon to reduce the acceptor removal effect by radiation. After 1 MeV neutron equivalent fluence of 2.5$\times$10$^{15}$ n$_{eq}$/cm$^{2}$, which is the maximum fluence to which sensors will be exposed at ATLAS High Granularity Timing Detector (HGTD), the IHEP-IME second version (IHEP-IMEv2) 50 $\mu$m LGAD sensors already deliver adequate charge collection > 4 fC and time resolution < 50 ps at voltages < 400 V. The operation voltages of these 50 $\mu$m devices are well below those at which single event burnout may occur.

physics.ins-det

Recent Progress and Next Steps for the MATHUSLA LLP Detector

We report on recent progress and next steps in the design of the proposed MATHUSLA Long Lived Particle (LLP) detector for the HL-LHC as part of the Snowmass 2021 process. Our understanding of backgrounds has greatly improved, aided by detailed simulation studies, and significant R&D has been performed on designing the scintillator detectors and understanding their performance. The collaboration is on track to complete a Technical Design Report, and there are many opportunities for interested new members to contribute towards the goal of designing and constructing MATHUSLA in time for HL-LHC collisions, which would increase the sensitivity to a large variety of highly motivated LLP signals by orders of magnitude.

hep-ex

Effects of shallow carbon and deep N++ layer on the radiation hardness of IHEP-IME LGAD sensors

Low Gain Avalanche Diode (LGAD) is applied for the High-Granularity Timing Detector (HGTD), and it will be used to upgrade the ATLAS experiment. The first batch IHEP-IME LGAD sensors were designed by the Institute of High Energy Physics (IHEP) and fabricated by the Institute of Microelectronics (IME). Three IHEP-IME sensors (W1, W7 and W8) were irradiated by the neutrons up to the fluence of 2.5 x 10^15 n_eq/cm^2 to study the effect of the shallow carbon and deep N++ layer on the irradiation hardness. Taking W7 as a reference, W1 has an extra shallow carbon applied, and W8 has a deeper N++ layer.

physics.ins-det

The performance of IHEP-NDL LGAD sensors after neutron irradiation

The performances of Low Gain Avalanche diode (LGAD) sensors from a neutron irradiation campaign with fluences of 0.8 x 10^15, 15 x 10^15 and 2.5 x 10^15 neq/cm2 are reported in this article. These LGAD sensors are developed by the Institute of High Energy Physics, Chinese Academy of Sciences and the Novel Device Laboratory for the High Granularity Timing Detector of the High Luminosity Large Hadron Collider. The timing resolution and collected charge of the LGAD sensors were measured with electrons from a beta source. After irradiation with a fluence of 2.5 x 10^15 neq/cm2, the collected charge decreases from 40 fC to 7 fC, the signal-to-noise ratio deteriorates from 48 to 12, and the timing resolution increases from 29 ps to 39 ps.

physics.ins-det

Mass production and characterization of 3-inch PMTs for the JUNO experiment

26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes rejected. The mass production began in 2018 and elapsed for about 2 years at a rate of $\sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.

physics.ins-det

A practical approach of high precision U and Th concentration measurement in acrylic

The Jiangmen Underground Neutrino Observatory will build the world's largest liquid scintillator detector to study neutrinos from various sources. The 20 kt liquid scintillator will be stored in a $\sim$600 t acrylic sphere with 35.4 m diameter due to the good light transparency, chemical compatibility and low radioactivity of acrylic. The concentration of U/Th in acrylic is required to be less than 1 ppt (10$^{-12}$ g/g) to achieve a low radioactive background in the fiducial volume of the JUNO detector. The mass production of acrylic has started, and the quality control requires a fast and reliable radioassay on U/Th in acrylic. We have developed a practical method of measuring U/Th in acrylic to sub-ppt level using the Inductively Coupled Plasma Mass Spectrometer (ICP-MS). The U/Th in acrylic can be concentrated by vaporizing acrylic in a class 100 environment, and the residue will be collected and sent to ICP-MS for measuring U/Th. All the other chemical operation is done in a class 100 clean room, and the ICP-MS measurement is done in a class 1000 clean room. The recovery efficiency is studied by adding the natural nonexistent nuclei $^{229}$Th and $^{233}$U as the tracers. The resulting method detection limit (MDL) with 99% confidence can reach 0.02/0.06 pg $^{238}$U/$^{232}$Th /g acrylic with $\sim$75% recovery efficiency. This equipment and method can not only be used for the quality control of JUNO acrylic, but also be further optimized for the radioassay on other materials with extremely low radioactivity, such as ultra-pure water and liquid scintillator.

physics.ins-det