A practical approach of high precision U and Th concentration measurement in acrylic

Abstract

The Jiangmen Underground Neutrino Observatory will build the world's largest liquid scintillator detector to study neutrinos from various sources. The 20 kt liquid scintillator will be stored in a $\sim$600 t acrylic sphere with 35.4 m diameter due to the good light transparency, chemical compatibility and low radioactivity of acrylic. The concentration of U/Th in acrylic is required to be less than 1 ppt (10$^{-12}$ g/g) to achieve a low radioactive background in the fiducial volume of the JUNO detector. The mass production of acrylic has started, and the quality control requires a fast and reliable radioassay on U/Th in acrylic. We have developed a practical method of measuring U/Th in acrylic to sub-ppt level using the Inductively Coupled Plasma Mass Spectrometer (ICP-MS). The U/Th in acrylic can be concentrated by vaporizing acrylic in a class 100 environment, and the residue will be collected and sent to ICP-MS for measuring U/Th. All the other chemical operation is done in a class 100 clean room, and the ICP-MS measurement is done in a class 1000 clean room. The recovery efficiency is studied by adding the natural nonexistent nuclei $^{229}$Th and $^{233}$U as the tracers. The resulting method detection limit (MDL) with 99% confidence can reach 0.02/0.06 pg $^{238}$U/$^{232}$Th /g acrylic with $\sim$75% recovery efficiency. This equipment and method can not only be used for the quality control of JUNO acrylic, but also be further optimized for the radioassay on other materials with extremely low radioactivity, such as ultra-pure water and liquid scintillator.

Explore related subjects

Keep this discovery

BibTeXRIS

Chuanya Cao, Nan Li, Xiaoyu Yang, Jie Zhao, Yuanxia Li, Zhiyan Cai, Liangjian Wen, Xiaolan Luo, Yuekun Heng, Yayun Ding. 2020-11-13. A practical approach of high precision U and Th concentration measurement in acrylic. https://doi.org/10.1016/j.nima.2021.165377

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det