arXiv Science⌕ Search

arXiv subjects

Oriol Gomis-Bellmunt

Publications and source records attributed to Oriol Gomis-Bellmunt.

At least 37 records · Page 2Linked to original sources

A Matlab-based Toolbox for Automatic EMT Modeling and Small-Signal Stability Analysis of Modern Power Systems

The intensive integration of power converters is changing the way that power systems operate, leading to the emergence of new types of dynamic phenomena and instabilities. At the same time, converters act as an interface between traditional AC grids and their more recent DC counterparts, giving rise to hybrid AC/DC networks. These conditions increase the necessity for stability analysis tools that can simultaneously account for the newly-introduced dynamic phenomena and can also be applied for the stability study of hybrid networks. This paper presents a Matlab-based toolbox for small-signal analysis of hybrid AC/DC power systems considering electromagnetic-transient (EMT) models. The toolbox allows the automatized modeling of the system from the input data and offers options for modal, impedance and passivity analyses. In the paper, the structure and internal processes of the toolbox are duly discussed, together with all its features, both main and complementary. Its capabilities for stability analysis are demonstrated via comprehensive case studies of converter-based system of various size and topology.

eess.SY↗

Small-Signal Stability Analysis of Power Systems by Implicit Multilinear Models

This paper proposes a new approach to perform small-signal stability analysis based on linearization of implicit multilinear models. Multilinear models describe the system dynamics by multilinear functions of state, input, and algebraic variables. Using suitable transformations of variables, they can also represent trigonometric functions, which often occur in power systems modeling. This allows tensor representations of grid-following and grid-forming power converters. This paper introduces small-signal stability analysis of equilibrium points based on implicit multilinear models using generalized eigenvalues. The generalized eigenvalues are computed from linear descriptor models of the linearized implicit multilinear model. The proposed approach is tested using a 3-bus network example, first by comparing time-domain simulations of the implicit multilinear model with those of the nonlinear model, and second by comparing the generalized eigenvalues with those of the linearized nonlinear model. The results show that the decomposed tensor representation of the implicit multilinear model allows for a faster linearization compared to conventional methods in MATLAB Simulink.

eess.SY↗

Cell-based VSC Analysis Methodology: From Graph Laplacian to Converter Degrees of Freedom

Power-electronics-based converters are being considerably employed through the power system to interconnect multiple heterogeneous electrical layers. Furthermore, the intrinsic versatility to play with the converter network topology is widely exploited to accommodate a certain number of terminals and ports according with the specific application. On this regard, several converter arrangements can be encountered in power applications. Moreover, to properly establish both the operation and the control, the so-called degrees of freedom (DOFs) need to be assessed per each converter topology. On this matter, similarly to the well-known Clarke transformation, which clearly reveals the DOFs for the star-based topology system, further similar transformations can be achieved to depict the independent set of variables characterizing a certain converter structure. Referring to the cell-based class of Voltage Source Converter (VSC) topologies, including Modular Multilevel Converter (MMC); this article proposes a general methodology to determine the change of variable matrix transformation for several converter arrangements which are related to complete bi-partite and multi-partite graphs. The methodology lies in the graph Laplacian spectral analysis, which remarks the structural normal modes at the converter points of connections. Furthermore, for a complete characterization, the instantaneous power patterns formulations, based on the DOFs, are also introduced.

eess.SY↗

Optimizing Offshore Wind Integration through Multi-Terminal DC Grids: A Market-Based OPF Framework for the North Sea Interconnectors

Interconnecting price zones and remote renewable energy sources has emerged as a key solution to achieving climate goals. The objective of this work is to present a formulation that extends the base optimal power flow model with price zones constraints to forecast the operations of upcoming offshore wind developments integrated into a multi-terminal DC grid. A case study based on the 2030 development of the North Sea is used to exemplify the utilization of the formulation. Here, three cases are presented, one with the price as a parameter and the other two with the price as a variable dependent on power flows between price zones. The paper demonstrates that, for large power flows, it is necessary to include additional constraints beyond line limitations to accurately capture the effects of price zone exchanges.

eess.SY↗

Data-Driven Decision Making for Enhancing Small-Signal Stability in Hybrid AC/DC Grids Through Converter Control Role Assignment

Hybrid AC/DC transmission grids incorporate Modular Multilevel Converters functioning as Interconnecting Power Converters (IPCs). The control role assigned to each converter significantly influences grid dynamics. Traditionally, these converters operate with static control roles, but recent studies have proposed scheduling their roles based on day-ahead forecasts to enhance stability performance. However, in systems with high renewable energy penetration, forecast deviations can render scheduled control assignments suboptimal or even lead to instability. To address this challenge, this work proposes an online scheduling recalculation algorithm that dynamically adapts IPC control roles during system operation. The approach leverages a data-driven multi-criteria decision-making framework, integrating surrogate models of conventional small-signal stability analysis tools to enable a fast computation of system stability and stability performance indicators.

eess.SY↗

A Dynamic Similarity Index for Assessing Voltage Source Behaviour in Power Systems

Due to the fundamental transition to a power electronic dominated power system, the increasing diversity of dynamic elements underscores the need to assess their similarity to mature electrical engineering models. This article addresses the concept of the Dynamic Similarity Index (DSI) for its use in, power electronics-dominated networks. The DSI is a multipurpose tool developed to be used by different stakeholders (e.g., converter manufacturers and system operators). Such an index is calculated per frequency, which serves to anticipate potential differences in particular frequency ranges of interest between the model under study and the reference model. Within the scope of this study, the dynamic similarity of inverter-based generators to an ideal voltage source behind an impedance is assessed, due to the relevance of this fundamental circuit in the representation of generation units in power system studies. The article presents two potential applications based on this mathematical framework. First, for manufacturers to evaluate control performance compared to a reference model and second, it enables operators to diagnose buses with voltage vulnerability based on a user-defined reference Short-Circuit Ratio (SCR) value. The DSI results for these two case studies are validated using Matlab Simulink simulations.

eess.SY↗

Dual-Port Grid-Forming Interconnecting Power Converters in Hybrid AC/DC Grids

Interconnecting power converters (IPC) are the main elements enabling the interconnection of multiple high-voltage alternating current (HVAC) and high-voltage direct current (HVDC) subgrids. These converters can be classified either as grid-forming or grid-following. These roles can be assigned to both ac and dc terminals. This work compares state-of-the-art single-port grid-forming and grid-following control schemes with a dual-port grid-forming control scheme, which can simultaneously form a stable voltage on the ac and the dc sides. The dual-port grid-forming small-signal stability and dynamic behavior under fluctuations in the power flow are studied and compared against state-of-the-art control architectures. Moreover, the dual-port control scheme is validated and tested on a down-scaled laboratory platform with several transient events.

eess.SY↗

Exploring Wavelet Transformations for Deep Learning-based Machine Condition Diagnosis

Deep learning (DL) strategies have recently been utilized to diagnose motor faults by simply analyzing motor phase current signals, offering a less costly and non-intrusive alternative to vibration sensors. This research transforms these time-series current signals into time-frequency 2D representations via Wavelet Transform (WT). The dataset for motor current signals includes 3,750 data points across five categories: one representing normal conditions and four representing artificially induced faults, each under five different load conditions: 0, 25, 50, 75, and 100%. The study employs five WT-based techniques: WT-Amor, WT-Bump, WT-Morse, WSST-Amor, and WSST-Bump. Subsequently, five DL models adopting prior Convolutional Neural Network (CNN) architecture were developed and tested using the transformed 2D plots from each method. The DL models for WT-Amor, WT-Bump, and WT-Morse showed remarkable effectiveness with peak model accuracy of 90.93, 89.20, and 93.73%, respectively, surpassing previous 2D-image-based methods that recorded accuracy of 80.25, 74.80, and 82.80% respectively using the identical dataset and validation protocol. Notably, the WT-Morse approach slightly exceeded the formerly highest ML technique, achieving a 93.20% accuracy. However, the two WSST methods that utilized synchrosqueezing techniques faced difficulty accurately classifying motor faults. The performance of Wavelet-based deep learning methods offers a compelling alternative for machine condition monitoring.

eess.SP↗

Deep Learning-based Machine Condition Diagnosis using Short-time Fourier Transformation Variants

In motor condition diagnosis, electrical current signature serves as an alternative feature to vibration-based sensor data, which is a more expensive and invasive method. Machine learning (ML) techniques have been emerging in diagnosing motor conditions using only motor phase current signals. This study converts time-series motor current signals to time-frequency 2D plots using Short-time Fourier Transform (STFT) methods. The motor current signal dataset consists of 3,750 sample points with five classes - one healthy and four synthetically-applied motor fault conditions, and with five loading conditions: 0, 25, 50, 75, and 100%. Five transformation methods are used on the dataset: non-overlap and overlap STFTs, non-overlap and overlap realigned STFTs, and synchrosqueezed STFT. Then, deep learning (DL) models based on the previous Convolutional Neural Network (CNN) architecture are trained and validated from generated plots of each method. The DL models of overlap-STFT, overlap R-STFT, non-overlap STFT, non-overlap R-STFT, and synchrosqueezed-STFT performed exceptionally with an average accuracy of 97.65, 96.03, 96.08, 96.32, and 88.27%, respectively. Four methods outperformed the previous best ML method with 93.20% accuracy, while all five outperformed previous 2D-plot-based methods with accuracy of 80.25, 74.80, and 82.80%, respectively, using the same dataset, same DL architecture, and validation steps.

eess.SP↗

Power Oscillation Damping Controllers for Grid-Forming Power Converters in Modern PowerSystems

Inter-area oscillations have been extensively studied in conventional power systems dominated by synchronous machines, as well as methods to mitigate them. Several publications have addressed Power Oscillation Damping (POD) controllers in grid-following voltage source converters (GFOL). However, the performance of POD controllers for Grid-Forming voltage source converters (GFOR) in modern power systems with increased penetration of power electronics requires further investigation. This paper investigates the performance of GFORs and supplementary POD controllers in the damping of electromechanical oscillations in modern power systems. This paper proposes POD controllers in GFORs by supplementary modulation of active- and reactive-power injections of the converter and both simultaneously (POD- P, POD-Q and POD-PQ, respectively). The proposed POD controllers use the frequency imposed by the GFOR as the input signal, which has a simple implementation and it eliminates the need for additional measurements. Eigenvalue-sensitivity methods using a synthetic test system are applied to the design of POD controllers in GFORs, which is useful when limited information of the power system is available. This paper demonstrates the effectiveness of POD controllers in GFOR converters to damp electromechanical oscillations, by small-signal stability analysis and non-linear time-domain simulations in a small test system and in a large-scale power system.

eess.SY↗

An Effective Methodology for Short-Circuit Calculation of Power Systems Dominated by Power Electronics Converters Considering Unbalanced Voltage Conditions and Converter Limits

This paper deals with the challenge of short-circuit calculation for power systems dominated by power electronics converters. A novel methodology has been presented to identify short-circuit equilibrium point of the studied system considering the operation and limitations of power converters. The studied system has been modeled with an element-based steady-state formulation. In particular, the governing equations implemented on converter control, which involve a specific control mode and various potential current-saturation states, are included. Then, an effective and efficient approach has been proposed to identify the short-circuit equilibrium points that satisfies converters limitations. Numerical case studies with VSCs show that the proposed methodology can identify the short-circuit equilibrium point efficiently and accurately with different types and depths of short-circuit fault. The short-circuit calculation results have been validated with dynamic simulations.

eess.SY↗

Grid-Forming Loads: Can the loads be in charge of forming the grid in modern power systems?

Modern power systems are facing the tremendous challenge of integrating vast amounts of variable (non-dispatchable) renewable generation capacity, such as solar photovoltaic or wind power. In this context, the required power system flexibility needs to be allocated in other units that can include energy storage, demand management or providing reserve from renewables curtailing the output power. The present paper proposes the new concept of grid-forming load, which can be considered a totally flexible concept of demand. The concept is not only ensuring the load is supporting the grid stability by adapting the load to the overall system balancing, but also ensures that the load is actually contributing to form the grid and to provide synchronization power to the overall system. In this sense, the new concept allows running a system powered only by renewables operating at maximum power (or operator defined set-point) in grid-following mode, while the overall system control is ubicated in the demand side. This is an important change of paradigm as it considers that all the flexibility, synchronism and stability provision is on the demand side. This concept can applied either to isolated systems or also to future power systems, where millions of loads steer the power system while the renewables are operating at full power. The paper proposes the concept, suggests possible control implementations of the grid-forming load and analyses the concept in four simulation case studies.

eess.SY↗

Passivity-based design and analysis of phase-locked loops

We consider a grid-connected voltage source converter (VSC) and address the problem of estimating the grid angle and frequency, information that is essential for an appropriate operation of the converter. We design phase-locked loop (PLL) algorithms with guaranteed stability properties, under the assumption that the grid is characterized by relatively high short-circuit-ratio (SCR) and inertia. In particular we derive, using passivity arguments, generalization of the conventional synchronous reference frame (SRF) and arctangent (ATAN) PLL, which are the standard solutions in power applications. The analysis is further extended to the case of connection of the VSC to a low-inertia grid, ensuring robustness of the algorithms in case of frequency variations. The results are validated on a benchmark including the grid, the VSC and related controllers.

eess.SY↗

An Observer-Based Composite Identifier for Online Estimation of the Thevenin Equivalent Parameters of a Power System

We consider a Thévenin equivalent circuit capturing the dynamics of a power grid as seen from the point of common coupling with a power electronic converter, and provide a solution to the problem of online identification of the corresponding circuit parameters. For this purpose, we first derive a linear regression model in the conventional abc coordinates and next design a bounded observer-based composite identifier that requires local measurements and knowledge of the grid frequency only. An extension that guarantees exponential convergence of the estimates, under the additional assumption of knowledge of the grid X/R ratio, is further provided. The performance of the proposed identifier, which subsumes a conventional gradient descent algorithm, is illustrated via detailed computer simulations.

eess.SY↗

Dual-port grid-forming control of MMCs and its applications to grids of grids

This work focuses on grid-forming (GFM) control of Interconnecting Power Converters (IPCs) that are used to interconnect multiple HVAC and HVDC subgrids to form a grid of grids. We introduce the concept of dual-port GFM control that leverages the ability of Modular Multilevel Converters (MMCs) to simultaneously form its AC and DC terminal voltage and present two dual-port GFM MMC controls. We provide analytical results and high-fidelity simulations that demonstrate that (i) dual-port GFM control is more resilient to contingencies (i.e., line and generator outages) than state-of-the-art single-port GFM control, and (ii) unlike single-port GFM control, dual-port GFM control does not require assigning grid-forming and grid-following (GFL) roles to the IPC terminals in grids of grids. Finally, we provide an in-depth discussion and comparison of single-port GFM control and the proposed dual-port GFM controls.

eess.SY↗

An Almost Globally Stable Adaptive Phase-Locked Loop for Synchronization of a Grid-Connected Voltage Source Converter

In this paper we are interested in the problem of adaptive synchronization of a voltage source converter with a possibly weak grid with unknown angle and frequency, but knowledge of its parameters. To guarantee a suitable synchronization with the angle of the three-phase grid voltage we design an adaptive observer for such a signal requiring measurements only at the point of common coupling. Then we propose two alternative certainty-equivalent, adaptive phase-locked loops that ensure the angle estimation error goes to zero for almost all initial conditions. Although well-known, for the sake of completeness, we also present a PI controller with feedforward action that ensures the converter currents converge to an arbitrary desired value. Relevance of the theoretical results and their robustness to variation of the grid parameters are thoroughly discussed and validated in the challenging scenario of a converter connected to a grid with low short-circuit-ratio.

eess.SY↗

Phasor Modelling Approaches and Simulation Guidelines of Voltage-Source Converters in Grid-Integration Studies

This paper reviews Voltage-Source Converters (VSCs) EMT and Phasor models currently used to simulate converter-interfaced generation (CIG) and renewable energy resources integration to power systems. Several modelling guidelines and suitability analyses were provided based on a comprehensive comparative study among the models. Various studies were performed in a small system and a large system, modelled in Simulink. We address a gap related to the suitability of CIGs phasor models in studies where the boundary between electromagnetic and electromechanical transients overlap. An insightful analysis of the adequate simulation time step for each model and study is also provided, along with several simulation guidelines.

eess.SY↗

Modelling and Simulation of Power Systems with Grid-Connected Converters in OpenModelica

This paper analyses the capabilities of the OpenModelica environment to perform electromagnetic transient (EMT) type simulations of power transmission systems with grid-connected converters. A power transmission system has been modelled and simulated in OpenModelica and Simulink to compare both tools in terms of accuracy, robustness, flexibility and computational performance. Power system transient studies such as faults and switching of capacitor banks have been performed. The results confirmed an excellent overall agreement between both software and demonstrated a remarkable potential for using OpenModelica for EMT-type modelling and simulation of future power electronic dominated grids.

eess.SY↗