arXiv Science⌕ Search

arXiv subjects

Oriol Gomis-Bellmunt

Publications and source records attributed to Oriol Gomis-Bellmunt.

At least 19 recordsLinked to original sources

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

eess.SY↗

Distribution Network Reconfiguration: A Reproducible Benchmark of Heuristic, Metaheuristic and Mathematical Methods

Distribution network reconfiguration (DNR) has been studied for five decades, yet published algorithms are rarely compared under identical assumptions: authors report results on different test systems, with different power-flow models, and almost never release code. This paper re-implements eight representative DNR algorithms in a single open-source Python framework and benchmarks them on five networks under identical conditions. The algorithms span three of the four established paradigms: heuristics (loop cutting, branch exchange, greedy minimum spanning tree, exhaustive search), metaheuristics (a genetic algorithm and a selective binary particle swarm optimizer) and mathematical programming (a mixed-integer quadratic program built on a convex, simplified DistFlow power-flow model). We report power losses, voltage profile, and, as a hardware-independent cost metric, the number of power-flow evaluations required for convergence. On the 196-bus Simbench urban network, we show that a dynamic DNR policy can save more than 26% of the system losses, weighed against circuit-breaker maintenance cost. All implementations, test cases, and result scripts are released to allow direct extension and replication

eess.SY↗

Unified Heterogeneous Graph Neural Network solver for Power Flow, Optimal Power Flow and State Estimation

Power Flow (PF), Optimal Power Flow (OPF), and State Estimation (SE) are fundamental problems in power system analysis, but solving them is computationally expensive. Graph Neural Networks (GNNs) have been proposed as fast surrogates, yet existing solvers are trained for a single problem at a time, producing narrow models that must be rebuilt for each new task. We propose a more general approach: a single Heterogeneous Residual Gated Graph Convolutional Network that solves all three problems with one shared backbone. Rather than learning one mapping, the model learns a reusable representation of how the network behaves, from which PF, OPF, and SE can each be estimated. Trained jointly on the three problems across diverse topologies and loading conditions, and evaluated on the IEEE 14-bus and 118-bus systems, the shared model matches the accuracy of task-specific GNN solvers and stays robust on unseen loading levels and topologies. These results show that a single model can capture the basic operation of a power network and serve several analysis tasks at once, a first step toward a foundation model for power systems.

eess.SY↗

Cybersecurity in Power Grids: Standards and Research Challenges

This paper examines Smart Grid cybersecurity, emphasizing the critical distinctions between IT and OT environments. It analyzes grid architecture, substation threats, and key international standards, specifically IEC 62351, IEC 62443, and ISO 27001. Finally, it overviews latest research trends, including AI-driven threat detection.

cs.CR↗

Impedance-Based Sensitivity Analysis for Stability Enhancement of LCC-HVDC Links Connected to Weak Grids Using Grid-Forming Converters

This paper presents a frequency-domain, impedance-based sensitivity methodology for stability assessment and enhancement of line-commutated converter HVDC (LCC-HVDC) links operating under weak-grid conditions. The methodology integrates frequency-domain identification tailored for black-box systems, the Generalized Nyquist Criterion (GNC) for multivariable stability assessment, and modal impedance decomposition with participation-factor analysis to locate and interpret interaction mechanisms. The approach is validated against a detailed linearized state-space model and nonlinear EMT simulations of an LCC-HVDC benchmark. A sensitivity study varying the grid short-circuit ratio (SCR) reveals a stability limit for the standalone LCC-HVDC link and demonstrates that the integration of a grid-forming voltage source converter (GFM-VSC) substantially increases the stability margin.

eess.SY↗

Quantifying Power to Voltage and Frequency Dynamics for Oscillation Propagation Assessment

The integration of Inverter-Based Resources (IBRs) into power systems introduces multi-timescale dynamics and oscillations which may propagate to distant areas and endanger the safe system operation. These oscillations pose a significant challenge as their source, frequency, and propagation pathways are often challenging to identify in large interconnected systems, comprising numerous synchronous machines and IBRs. For the above reasons, analytical tools that identify the sensitivity of the system to oscillations within a large frequency spectrum, affecting both voltage and frequency variables across various network locations, are of interest. This paper addresses this topic by introducing a frequency-domain framework based on linear analysis, which characterizes the sensitivity to oscillations of each network bus voltage and of each generation unit frequency. Within this framework, two quantitative indicators are proposed, namely the Frequency Sensitivity Index (FSI) and Voltage Sensitivity Index (VSI). These indexes are derived analytically from the transfer functions which relate the active and reactive power injections to each bus with the voltage and frequency variables across the network, derived from the linear Electromagnetic Transient (EMT) power system model. The proposed indices quantify the sensitivity of the system to oscillations of different type and frequency, providing insights for both oscillation detection and propagation analysis. The methodology is applied to a case study based on the modified IEEE 68-bus benchmark system under partial and full IBR penetration, while its accuracy is validated through EMT time-domain simulations using linear and nonlinear models developed in Matlab/Simulink environment.

eess.SY↗

Use of the Common Information Model (IEC 61970) for Standardized Data Exchange in HVDC Digital Twin Systems

Digital Twins (DTw) are emerging as transformative tools for High Voltage Direct Current (HVDC) transmission systems, enabling real-time monitoring, predictive maintenance, and operational optimization. However, the effectiveness of these virtual replicas fundamentally depends on seamless, reliable data exchange with their physical counterparts and any other support system. The current landscape of HVDC DTw implementations reveals a critical challenge: the absence of standardized data exchange protocols leads to vendor lock-in, interoperability issues between systems from different vendors. The contribution of this paper is to propose the standardization of Common Information Model (CIM) defined in IEC 61970 standard family, as the data exchange methodology in HVDC DTws, which is exemplified with the Cigre B4 example, as well as connected to the IEC 61850 standard for real time station control, via the harmonization guidelines from the IEC 62361-102 technical report.

eess.SY↗

Power Flow Feasibility Assessment Using Variational Graph Autoencoders

Data-driven methods, including graph neural networks, have been studied for accelerating power flow calculations in recent years, but very little attention has been paid to the solution feasibility, which can be obtained by traditional solvers. This paper presents a Variational Graph Autoencoder (VGAE) that detects the power flow solution feasibility, using the IEEE 118-bus case, to assess the validity of the solutions provided by AI-driven solvers.

cs.LG↗

Distributed Air-Gap Flux and Rotor-Current Fusion for Operating-Regime Identification in a 10-MW Kaplan Hydrogenerator

Reliable monitoring of hydroelectric generators requires descriptors that capture both electrical loading and electromagnetic field behavior. This work investigates operating-regime identification in the Porjus U9 10-MW Kaplan hydrogenerator using synchronized measurements from ten stator-mounted Hall probes and six rotor-current channels. Seven steady guide-vane-opening settings are considered, and each 300s record is divided into 1s windows. The resulting windows are represented by spatial Fourier descriptors of the circumferential air-gap field, probe-wise temporal flux indicators, and channel-wise RMS rotor-current features. Correlation analysis and principal component analysis are used to examine how the feature groups vary with the operating point, and Random Forest, radial-basis-function support vector classification, and multilayer perceptron models are evaluated for supervised identification of the guide-vane-opening state. The analysis shows that RMS rotor-current features mainly track the loading axis, while the magnetic-flux features reveal complementary information associated with spatial imbalance, waveform distortion, and weak low-frequency modulation. Spatial descriptors alone provide limited separability, yielding test accuracies below 27%, whereas rotor-current features alone reach about 84-85%. Combining flux and current information gives the most discriminative representation; the SVC-RBF model achieves 99.5% test accuracy and macro-F1 score. The results indicate that distributed air-gap magnetic sensing, when fused with rotor-current measurements, can support accurate and interpretable data-driven monitoring of Kaplan hydrogenerator operating regimes.

eess.SP↗

Early Anomaly-Onset Detection based on Wigner--Ville Distribution Slice Spectra: A Transmission-Grid Test Case

Operational disturbance monitoring in power networks requires decisions to be made from waveform windows as they arrive, rather than from completed records after the event. This study evaluates full-vector Wigner--Ville Distribution Slice (WVDS) spectra for sequential anomaly-onset detection in high-voltage grid-voltage waveforms. The approach keeps the bilinear midpoint interaction structure of the Wigner--Ville distribution and represents each 128-sample voltage window by a 128-dimensional slice spectrum, avoiding manually selected fault-frequency markers. WVDS is used with a baseline-normalized deviation (BND) score and is compared against the BND of Fast Fourier Transform (FFT-BND), raw-window autoencoders, FFT autoencoders, and WVDS autoencoders under the same thresholding and three-window persistence rule. A synthetic autoencoder--clustering teacher is used to select RTE fault records that start from an initially normal region and then transition to anomalous behavior. On the filtered test set, FFT-BND achieves the highest sensitivity, whereas WVDS-BND provides the lowest false-alarm operating point, reducing record-level pre-onset false alarms to 0.69%. The autoencoder comparison follows the same selectivity pattern: WVDS reconstruction decreases false alarms relative to FFT reconstruction but misses more examples. The results indicate that preserved WVD cross-term information can form a selective representation for online grid-waveform anomaly monitoring when false alarms are costly.

eess.SP↗

Systematic Gray-Box Identification Methodology for Voltage Source Converters

This paper introduces a systematic gray-box identification framework for voltage-source converter models based solely on terminal time-series data. The proposed approach combines a physically informed white-box standard model with iterative time-domain calibration to estimate controller parameters that mimic the behavior of the black-box model in electromagnetic transient (EMT) simulations. Unlike conventional frequency-domain identification methods, the framework leverages time-domain data more effectively to better constrain the surrogate model across a broader operating range and capture reference-signal dynamics. To evaluate the accuracy of the identified model, the paper presents additional frequency-domain validation metrics based on Nyquist analysis and singular value decomposition, allowing for both quantitative assessment of model divergence and qualitative classification of mismatch types. The methodology is tested on cases with increasing structural uncertainty, from exact parametric recovery to an actual detailed EMT black-box model. Results demonstrate that the proposed framework can accurately recover parameters when the internal structure is known, adjust for moderate structural mismatch with extra degrees of freedom, and offer a reliability measure for small-signal stability analysis of converter models protected by intellectual property

eess.SY↗

Fault-Ride-Through Coordination Strategy for Offshore AC Islands with Multi-Infeed HVDC Interconnections

Large-scale offshore Wind Farms (WFs) are considered key assets towards realizing a sustainable power system. These systems are often configured as offshore AC islands and their integration largely depends on the High-Voltage-Direct-Current (HVDC) technology. This topology, while it enables cost-effective transmission over large offshore distances, may lead to operational challenges. Specifically, the operation of offshore AC islands during faults and the grid code requirement fulfillment are identified as a major challenges for their large-scale deployment. To address this pressing issue, a comprehensive coordination control strategy for the different participating converters in multi-infeed AC offshore islands during Fault Ride Through (FRT) operation is presented in this work. The proposed strategy introduces advanced control functions in the FRT schemes of both the HVDC and WF converters, such as zero active and reactive power injection during faults, as well as post-fault active power droop control coordination to tackle power imbalances. The proposed FRT coordination strategy is validated through both extensive simulations in PSCAD/EMTDC, as well as with Power Hardware-in-the-Loop (PHIL) experimental results, considering both AC and DC faults.

eess.SY↗

Enabling Small-Signal Stability Analysis of Black-Box Voltage Source Converters in Large-Scale Modern Power Systems

Modern power systems increasingly rely on power electronic converters, yet many of these devices are provided as black-box models, limiting the applicability of conventional small-signal analysis (SSA) tools. This work presents a unified multi-variable fitted state-space (SSA-FITSS) methodology that enables accurate small-signal modeling of black-box Voltage Source Converters (VSCs) using frequency-domain (FD) identification, adaptive pole-expansion, and reduced-order realization. The method includes an automated state-interpretation strategy that assigns fitted states to representative control-loop categories based on their dominant frequency ranges, providing an approximate but meaningful physical interpretation of the identified dynamics. This capability allows extensive modal analysis, including eigenvalue sensitivities and participation factors, in systems where internal converter details are unavailable. The methodology is validated on a grid-following (GFL) VSC and applied to the New England system, which contains multiple black-box converters operating in both GFL and grid-forming (GFM) modes. Results show that the SSA-FITSS models accurately reproduce converter and system dynamics, support full eigenvalue-based analysis, and reveal stability limits under varying synchronous generation and GFL penetration levels. The approach overcomes key limitations of existing identification-based techniques by enabling scalable, interpretable, and system-wide stability assessment.

eess.SY↗

Small-Signal Stability Oriented Real-Time Operation of Power Systems with a High Penetration of Inverter-Based Resources

This study proposes a control strategy to ensure the safe operation of modern power systems with high penetration of inverter-based resources (IBRs) within an optimal operation framework. The objective is to obtain operating points that satisfy the optimality conditions of a predefined problem while guaranteeing small-signal stability. The methodology consists of two stages. First, an offline analysis of a set of operating points is performed to derive a data-driven regression-based expression that captures a damping-based stability index as a function of the operating conditions. Second, an Online Feedback Optimization (OFO) controller is employed to drive the system toward an optimal operating point while maintaining a secure distance from the instability region. The proposed strategy is evaluated on an academic test case based on a modified version of the IEEE 9-bus system, in which synchronous generators are replaced by IBRs operating under both grid-following and grid-forming control modes. The results demonstrate the effectiveness of the method and are discussed in detail.

eess.SY↗

Performance of Differential Protection Applied to Collector Cables of Offshore Wind Farms with MMC-HVDC Transmission

The ongoing global transition towards low-carbon energy has propelled the integration of offshore wind farms, which, when combined with Modular Multilevel Converter-based High-Voltage Direct Current (MMC-HVDC) transmission, present unique challenges for power system protection. In collector cables connecting wind turbines to offshore MMC, both ends are supplied by Inverter-Based Resources (IBRs), which modify the magnitude and characteristics of fault currents. In this context, this paper investigates the limitations of conventional differential protection schemes under such conditions and compares them with enhanced strategies that account for sequence components. Using electromagnetic transient simulations of a representative offshore wind farm modeled in PSCAD/EMTDC software, internal and external fault scenarios are assessed, varying fault types and resistances. The comparative evaluation provides insights into the sensitivity and selectivity of differential protection and guides a deeper conceptual understanding of the evolving protection challenges inherent to future converter-dominated grids.

eess.SY↗

SIaD-Tool: A Comprehensive Frequency-Domain Tool for Small-Signal Stability and Interaction Assessment in Modern Power Systems

This paper presents SIaD-Tool, an open-source frequency-domain (FD) scanning solution for stability and interaction assessment in modern power systems. The tool enables multi-sequence identification in the abc, dq0, and 0pn frames and supports both series voltage and parallel current perturbation strategies. A novel perturbation scheme allows direct scanning in the target frame, simplifying the analysis of coupling effects and mirrored frequencies. SIaD-Tool is implemented on a multi-platform architecture, including MATLAB/Simulink and Python-PSCAD/EMTDC. Beyond system identification, it integrates automated stability evaluation through four standardized methods: Generalized Nyquist Criterion (GNC), modal impedance analysis, phase margin assessment, and passivity checks. Validation is carried out via extensive case studies involving passive elements, grid-following and grid-forming converters, offshore wind power plants, and the IEEE 9-bus system. Results confirm high accuracy, scalability, and robustness in detecting critical modes, interaction frequencies, oscillatory behavior, and stability margins.

eess.SY↗

Influence of converter current limiting and prioritization on protection of highly IBR-penetrated networks

This paper investigates how grid-forming (GFM) and grid-following (GFL) control strategies in inverter-based resources (IBRs) influence line distance and differential protection in converter-dominated transmission systems. A modified IEEE 39-bus system is evaluated with GFM and GFL units equipped with low-voltage ride-through logic, current limiting, and positive- or negative-sequence prioritization. Distance protection is implemented with a mho characteristic, while line differential protection uses an alpha-plane approach. Results show that phase-to-ground loops in distance protection can substantially overestimate the fault location near the Zone-1 reach. For line differential protection, external faults may cause the operating point to briefly enter the trip region of the alpha-plane, even for the healthy-phase in ABG faults under GFL control and during the initial moments of the fault, demanding strong external security measures. These findings highlight that modern converter controls, together with current limitation and sequence-current prioritization, can compromise the reliability and security of traditional protection schemes.

eess.SY↗

Shaping Frequency Dynamics in Modern Power Systems with Grid-forming Converters

In this paper, frequency dynamics in modern power systems with a high penetration of converter-based generation is analysed. A fundamental analysis of the frequency dynamics is performed to identify the limitations and challenges when the converter penetration is increased. The voltage-source behaviour is found as an essential characteristic of converters to improve the initial frequency derivative of Synchronous Generators (SGs). A detailed small-signal analysis, based on the system's eigenvalues, participation factors and mode shapes, is then performed in a reduced system for different converter penetrations, showing that the flexibility of grid-forming (GFOR) converters as well as the system's inertia reduction may lead to have a more controllable system frequency. First-order frequency responses can be programmed for high converter penetrations, when GFOR operation can impose their dominance over SGs. These results have been validated in the IEEE 118-bus system simulated in PSCAD.

eess.SY↗