arXiv ScienceSearch

arXiv subjects

Michele Bonaldi

Publications and source records attributed to Michele Bonaldi.

12 recordsLinked to original sources

Large amplitude mechanical coherent states and detection of weak nonlinearities in cavity optomechanics

The generation of large-amplitude coherent states of a massive mechanical resonator, and their quantum-limited detection represent useful tools for quantum sensing and for testing fundamental physics theories. In fact, any weak perturbation may affect the coherent quantum evolution of the prepared state, providing a sensitive probe for such a perturbation. Here we consider a cavity optomechanical setup and the case of the detection of a weak mechanical nonlinearity. We consider different strategies, first focusing on the stationary dynamics in the presence of multiple tones driving the system, and then focusing on non-equilibrium dynamical strategies. These methods can be successfully applied for measuring Duffing-like material nonlinearities, or effective nonlinear corrections associated with quantum gravity theories.

quant-ph

Mechanical characterization of a membrane with an on-chip loss shield in a cryogenic environment

The quantum transduction of an rf/microwave signal to the optical domain, and vice versa, paves the way for technologies that exploit the advantages of each domain to perform quantum operations. Since electro-optomechanical devices implement a simultaneous coupling of a mechanical oscillator to both an rf/microwave field and an optical field, they are suitable for the realization of a quantum transducer. The membrane-in-the-middle setup is a possible solution, once its vibrational mode is cooled down to ultra cryogenic temperature for achieving quantum operation. This work is focused on the mechanical characterization via an optical interferometric probe, down to T=18mK, of a loss-shielded metalized membrane designed for this purpose. A stroboscopic technique has been exploited for revealing a mechanical quality factor up to 64 millions at the lowest temperature. In fact, with continuous illumination and a cryostat temperature below 1K, the heat due to optical absorption is not efficiently dissipated anymore, and the membrane remains hotter than its environment.

quant-ph

Low Noise Opto-Electro-Mechanical Modulator for RF-to-Optical Transduction in Quantum Communications

In this work, we present an Opto-Electro-Mechanical Modulator (OEMM) for RF-to-optical transduction realized via an ultra-coherent nanomembrane resonator capacitively coupled to an rf injection circuit made of a microfabricated read-out able to improve the electro-optomechanical interaction. This device configuration can be embedded in a Fabry-Perot cavity for electromagnetic cooling of the LC circuit in a dilution refrigerator exploiting the opto-electro-mechanical interaction. To this aim, an optically measured steady-state frequency shift of 380 Hz was seen with a polarization voltage of 30 V and a $Q$-factor of the assembled device above $10^6$ at room temperature. The rf-sputtered titanium nitride layer can be made superconductive to develop efficient quantum~transducers.

quant-ph

Active feedback cooling of a SiN membrane resonator by electrostatic actuation

Feedback-based control techniques are useful tools in precision measurements as they allow to actively shape the mechanical response of high quality factor oscillators used in force detection measurements. In this paper we implement a feedback technique on a high-stress low-loss SiN membrane resonator, exploiting the charges trapped on the dielectric membrane. A properly delayed feedback force (dissipative feedback) enables the narrowing of the thermomechanical displacement variance in a similar manner to the cooling of the normal mechanical mode down to an effective temperature Te f f . In the experiment here reported we started from room temperature and gradually increasing the feedback gain we were able to cool down the first normal mode of the resonator to a minimum temperature of about 124mK. This limit is imposed by our experimental set-up and in particular by the the injection of the read-out noise into the feedback. We discuss the implementation details and possible improvements to the technique

physics.app-ph

Silicon-nitride nanosensors toward room temperature quantum optomechanics

Observation of quantum phenomena in cryogenic, optically cooled mechanical resonators has been recently achieved by a few experiments based on cavity optomechanics. A well-established experimental platform is based on a thin film stoichiometric ($ Si_3 N_4 $) nanomembrane embedded in a Fabry-Perot cavity, where the coupling with the light field is provided by the radiation pressure of the light impinging on the membrane surface. Two crucial parameters have to be optimized to ensure that these systems work at the quantum level: the cooperativity $ C$ describing the optomechanical coupling and the product $ Q \times \nu$ (quality factor - resonance frequency) related to the decoherence rate. A significant increase of the latter can be obtained with high aspect-ratio membrane resonators where uniform stress dilutes the mechanical dissipation. Furthermore, ultra-high $Q \times \nu$ can be reached by drastically reducing the edge dissipation via clamp-tapering and/or by soft-clamping, virtually a clamp-free resonator configuration. In this work, we investigate, theoretically and experimentally, the edge loss mechanisms comparing two state-of-the-art resonators built by standard micro/nanofabrication techniques. The corresponding results would provide meaningful guidelines for designing new ultra-coherent resonating devices.

physics.optics

Silicon Nitride MOMS Oscillator for Room Temperature Quantum Optomechanics

Optomechanical SiN nano-oscillators in high-finesse Fabry-Perot cavities can be used to investigate the interaction between mechanical and optical degree of freedom for ultra-sensitive metrology and fundamental quantum mechanical studies. In this work we present a nano-oscillator made of a high-stress round-shaped SiN membrane with an integrated on-chip 3D seismic filter properly designed to reduce mechanical losses. This oscillator works in the 200 kHz - 5 MHz range and features a mechanical quality factor of $Q\simeq10^7$ and a Q-frequency product in excess of $6.2 \times 10^{12}$ Hz at room temperature, fulfilling the minimum requirement for quantum ground-state cooling of the oscillator in an optomechanical cavity. The device is obtained by MEMS DRIE bulk micromachining with a two-side silicon processing on a Silicon-On-Insulator (SOI) wafer. The microfabrication process is quite flexible and additional layers could be deposited over the SiN membrane before the DRIE steps, if required for a sensing application. Therefore, such oscillator is a promising candidate for quantum sensing applications in the context of the emerging field of Quantum Technologies.

physics.app-ph

Search for light scalar Dark Matter candidate with AURIGA detector

A search for a new scalar field, called moduli, has been performed using the cryogenic resonant-mass AURIGA detector. Predicted by string theory, moduli may provide a significant contribution to the dark matter (DM) component of our universe. If this is the case, the interaction of ordinary matter with the local DM moduli, forming the Galaxy halo, will cause an oscillation of solid bodies with a frequency corresponding to the mass of moduli. In the sensitive band of AURIGA, some $100\,\mathrm{Hz}$ at around $1\,\mathrm{kHz}$, the expected signal, with a $Q=\tfrac{\triangle f}{f}\sim10^{6}$, is a narrow peak, $\triangle f\sim1\,\mathrm{mHz}$. Here the detector strain sensitivity is $h_{s}\sim2\times10^{-21}\,\mathrm{Hz^{-1/2}}$, within a factor of $2$. These numbers translate to upper limits at $95\%\,C.L.$ on the moduli coupling to ordinary matter $d_{e}\lesssim10^{-5}$ around masses $m_{\phi}=3.6\cdot10^{-12}\,\mathrm{eV}$, for the standard DM halo model with $\rho_{DM}=0.3\,\mathrm{GeV/cm^{3}}$.

hep-ex

Probing deformed commutators with macroscopic harmonic oscillators

A minimal observable length is a common feature of theories that aim to merge quantum physics and gravity. Quantum mechanically, this concept is associated to a nonzero minimal uncertainty in position measurements, which is encoded in deformed commutation relations. In spite of increasing theoretical interest, the subject suffers from the complete lack of dedicated experiments and bounds to the deformation parameters are roughly extrapolated from indirect measurements. As recently proposed, low-energy mechanical oscillators could allow to reveal the effect of a modified commutator. Here we analyze the free evolution of high quality factor micro- and nano-oscillators, spanning a wide range of masses around the Planck mass $m_{\mathrm{P}}$ (${\approx 22\,\mu\mathrm{g}}$), and compare it with a model of deformed dynamics. Previous limits to the parameters quantifying the commutator deformation are substantially lowered.

gr-qc

Effects of breaking vibrational energy equipartition on measurements of temperature in macroscopic oscillators subject to heat flux

When the energy content of a resonant mode of a crystalline solid in thermodynamic equilibrium is directly measured, assuming that quantum effects can be neglected it coincides with temperature except for a proportionality factor. This is due to the principle of energy equipartition and the equilibrium hypothesis. However, most natural systems found in nature are not in thermodynamic equilibrium and thus the principle cannot be granted. We measured the extent to which the low-frequency modes of vibration of a solid can defy energy equipartition, in presence of a steady state heat flux, even close to equilibrium. We found, experimentally and numerically, that the energy separately associated with low frequency normal modes strongly depends on the heat flux, and decouples sensibly from temperature. A 4% in the relative temperature difference across the object around room temperature suffices to excite two modes of a macroscopic oscillator, as if they were at equilibrium, respectively, at temperatures about 20% and a factor 3.5 higher. We interpret the result in terms of new flux-mediated correlations between modes in the nonequilibrium state, which are absent at equilibrium.

cond-mat.stat-mech

Phonon momentum and damping of mechanical resonators

The concept of physical momentum associated to phonons in a crystal, complemented with some fundamental reasoning, implies measurable effects in crystals even at a macroscopic scale. We show that, in close analogy with the transfer of momentum in the kinetic theory of gases, physical momentum carried by of phonons couples the thermal and the velocity field in a vibrating crystal. Therefore an heat flow applied to a vibrating crystal can sustain or damp the oscillation, depending on the interplay between the temperature and the velocity gradient. We derive the general equations of this effect and show that its experimental confirmation is within reach of current technology.

cond-mat.mes-hall

Harmonic damped oscillators with feedback. A Langevin study

We consider a system in direct contact with a thermal reservoir and which, if left unperturbed, is well described by a memory-less equilibrium Langevin equation of the second order in the time coordinate. In such conditions, the strength of the noise fluctuations is set by the damping factor, in accordance with the Fluctuation and Dissipation theorem. We study the system when it is subject to a feedback mechanism, by modifying the Langevin equation accordingly. Memory terms now arise in the time evolution, which we study in a non-equilibrium steady state. Two types of feedback schemes are considered, one focusing on time shifts and one on phase shifts, and for both cases we evaluate the power spectrum of the system's fluctuations. Our analysis finds application in feedback cooled oscillators, such as the Gravitational Wave detector AURIGA.

cond-mat.stat-mech

Principles of wide bandwidth acoustic detectors and the single-mass DUAL detector

We apply the standard theory of the elastic body to obtain a set of equations describing the behavior of an acoustic Gravitational Wave detector, fully taking into account the 3-dimensional properties of the mass, the readout and the signal. We show that the advantages given by a Dual detector made by two nested oscillators can also be obtained by monitoring two different acoustic modes of the same oscillator, thus easing the detector realization. We apply these concepts and by means of an optimization process we derive the main figures of such a single-mass Dual detector designed specifically for the frequency interval 2-5kHz. Finally we calculate the SQL sensitivity of this detector.

gr-qc