arXiv · 2503.22602
Mechanical characterization of a membrane with an on-chip loss shield in a cryogenic environment
Abstract
The quantum transduction of an rf/microwave signal to the optical domain, and vice versa, paves the way for technologies that exploit the advantages of each domain to perform quantum operations. Since electro-optomechanical devices implement a simultaneous coupling of a mechanical oscillator to both an rf/microwave field and an optical field, they are suitable for the realization of a quantum transducer. The membrane-in-the-middle setup is a possible solution, once its vibrational mode is cooled down to ultra cryogenic temperature for achieving quantum operation. This work is focused on the mechanical characterization via an optical interferometric probe, down to T=18mK, of a loss-shielded metalized membrane designed for this purpose. A stroboscopic technique has been exploited for revealing a mechanical quality factor up to 64 millions at the lowest temperature. In fact, with continuous illumination and a cryostat temperature below 1K, the heat due to optical absorption is not efficiently dissipated anymore, and the membrane remains hotter than its environment.
Explore related subjects
Keep this discovery
Francesco Marzioni, Riccardo Natali, Michele Bonaldi, Antonio Borrielli, Enrico Serra, Bruno Morana, Francesco Marin, Francesco Marino, Nicola Malossi, David Vitali, Giovanni Di Giuseppe, Paolo Piergentili. 2025-03-28. Mechanical characterization of a membrane with an on-chip loss shield in a cryogenic environment. https://doi.org/10.1063/5.0268805
Cite the original work for its findings. Save a collection to share your selection of sources.