arXiv ScienceSearch

arXiv subjects

F. Petricca

Publications and source records attributed to F. Petricca.

At least 19 recordsLinked to original sources

Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment

The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CE$\nu$NS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this work, the cryogenic target-detector module for the NUCLEUS Technical Run was developed and commissioned at the Technical University of Munich. The module comprises four gram-scale CaWO$_4$ detectors, each equipped with two Transition Edge Sensors (TES), providing a total target mass of 6.96 g. We present the design, integration, detector characterization, and X-ray-based energy calibration of these detectors. Across six characterized detectors, a mean baseline resolution of $\overline{\sigma}_{\mathrm{BL}} = (2.79 \pm 0.60)\,\mathrm{eV}$ was achieved. The best-performing detector reached $\sigma_{\mathrm{BL}} = (2.16 \pm 0.02_{\mathrm{stat}})\,\mathrm{eV}$, surpassing the design goal by a factor of two and representing a state-of-the-art result for a cryogenic CaWO$_4$ detector. The target detector module was successfully operated simultaneously with the surrounding Cryogenic Outer Veto, which consists of six kg-scale Ge detectors for background discrimination, showing no measurable cross-talk. These results demonstrate the readiness of the target-detector system for the NUCLEUS Technical Run at Chooz and mark a key milestone in the development of cryogenic detectors for reactor-CE$\nu$NS measurements.

physics.ins-det

Optimization studies of silicon remoTES cryogenic calorimeters

The remoTES design, developed within the COSINUS experiment, enables a broader range of materials to be operated as cryogenic calorimeters read out with Transition Edge Sensors (TESs). In this configuration, the TES is fabricated onto a separate chip and thermally coupled to the absorber via a gold (Au) link. The remoTES concept has been successfully tested on various target materials. To further enhance detector performance and to fully exploit the advantages of the remote coupling design a series of optimization studies has been conducted using silicon (Si) absorbers as benchmark. This work presents an evaluation of several measurements aimed at reducing the thermal boundary resistance and enhancing signal transmission across Si remoTES interfaces, specifically from the absorber to the phonon collector and from the phonon collector to the TES. By testing a new Au link design and three distinct phonon collector configurations, Au, copper, and aluminum (Al)/Au, we achieved a baseline resolution of (21.5 +/- 0.3)eV using the Al/Au phonon collector.

physics.ins-det

Optimisation of TES design for the CRESST experiment

The CRESST experiment aims at the direct detection of sub-GeV dark matter particles via elastic scattering off nuclei in different target crystals at cryogenic temperatures. The advancement in W-TES sensors allowed the CRESST detectors to reach energy thresholds of 10 eV and lower, opening the way to the exploration of dark matter masses as low as 70 MeV/c2. This work presents optimisation studies of W-TESs aimed at further improving the signal-to-noise ratio and overall detector performance. In particular, we investigate the thickness, dimensions and material composition of phonon collectors and assess their impact on detector response. The results demonstrate a significant performance enhancement and establish new benchmarks for the sensors used within CRESST.

physics.ins-det

Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment

Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving the best sensitivity for this kind of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information on different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. With both techniques at the same time, we obtained a baseline resolution of 2.94 $\pm$ 0.05 (stat) eV using a CaWO4 based detector, achieving a promising result in view of the first run of NUCLEUS at the experimental site.

physics.ins-det

Prospect of the NUCLEUS Experiment at Chooz for Coherent Elastic Neutrino-Nucleus Scattering and New Physics Searches

The NUCLEUS experiment aims to measure coherent elastic neutrino-nucleus scattering (CE$\nu$NS) at unprecedentedly low nuclear recoil energies using gram-scale cryogenic calorimeters operated at the Chooz nuclear power plant in France. Access to recoil energies at the $\mathcal{O}(10~\mathrm{eV})$ scale enables CE$\nu$NS studies at extremely low momentum transfer and provides enhanced sensitivity to new physics. In this work, we present sensitivity projections for the upcoming NUCLEUS technical and physics runs, incorporating a data-driven treatment of the low-energy excess (LEE) observed during commissioning. We develop a likelihood framework that exploits reactor-power variation to disentangle signal and background in a low signal-to-background regime and to assess the impact of the dominant systematic uncertainties. For the Technical Run with a 7 g CaWO$_4$ target, we find competitive sensitivity to several scenarios beyond the Standard Model, which do not require a CE$\nu$NS observation. For the Physics Run, assuming complete suppression of the LEE, we project a 4.7 $\sigma$ observation of CE$\nu$NS with a statistical precision of about 20 % in 1 year, enabling a determination of the weak mixing angle at the lowest momentum transfer probed to date with CE$\nu$NS and leading CE$\nu$NS-based constraints on the neutrino charge radius and new mediator models.

hep-ex

Cosmic Ray Boosted Dark Matter in COSINUS: Modeling and Constraints

Direct detection of nuclear recoils due to sub-GeV dark matter is challenging because of the small kinetic energy of the light dark matter particles. Although limits down to a few hundred MeV have been reached using specially designed low threshold detectors, further improvements are now constrained more by background event rates than by energy thresholds. However, constraints down to sub-MeV dark matter masses can still be obtained through the boosted dark matter framework. In this scenario, high-energy cosmic rays or neutrinos scatter off dark matter particles, imparting additional kinetic energy and boosting them beyond the typical velocities expected from the non-relativistic dark matter halo. These boosted dark matter particles can then be detected even by experiments with higher energy thresholds. In this work, we present a catalog of dark matter - nucleon scattering cross sections corresponding to a heavy mediator limit for spin zero, one half and one dark matter and for scalar and vector mediators with even or odd parity. Based on these results, we present projected constraints on the dark matter - nucleon cross section for the COSINUS experiment, assuming an exposure of 100 kg d, demonstrating the potential sensitivity to sub-GeV boosted dark matter.

hep-ph

Characterization of the Low Energy Excess using a NUCLEUS Al$_{2}$O$_{3}$ detector

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $(-0.59 \pm 0.06)$, when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.

physics.ins-det

ImpCresst -- A versatile simulation tool focusing on solid-state detectors at keV energies

We present ImpCresst, a Geant4-based Monte Carlo tool to simulate backgrounds from natural and cosmogenic radionuclides, and calibration signals in solid-state detectors and their response to it. It is tuned for a fast-evolving and heterogeneous detector environment with a focus on physics at the keV range. This tool was originally developed and validated by the CRESST collaboration; however, its flexibility and configurability make it suitable for other experiments with similar requirements. Key features of ImpCresst include the dynamic geometry implementation directly from CAD files, ROOT-based data persistency of the whole event topology and automatic metadata annotation for data provenance, and interfaces to various particle generators, particularly for radiogenic and cosmogenic radionuclides. It includes also a newly developed particle generator for radioactive bulk and surface contaminations which is completely independent of any user defined confinement volumes. The auxiliary tool CresstDS applies detector-specific energy and time resolution based on a user-provided data set of empirical parameterization. We discuss also how to manage an ImpCresst based workflow in an HPC environment based on Apptainer and nextflow.

physics.ins-det

Defect Formation in NaI Crystals: A Novel Pathway to Dark Matter Detection

Sodium iodide (NaI) is a widely used scintillator in direct dark matter searches. In particular, NaI-based cryogenic scintillating calorimeters have emerged as promising candidates, like in the COSINUS experiment, for testing the annually modulating signal reported by DAMA/LIBRA. In this study, we investigate defect formation within NaI crystals and its impact on the dark matter detection signal. Using molecular dynamics simulations and density functional theory techniques, we simulate a DM particle collision on an NaI crystal, focusing on the possible defects formation and their structural and electronic properties. Our analysis includes a detailed study of the electronic states associated with the interstitial atoms and vacancies, the energetic cost of defect formation, and the anisotropic threshold displacement energy. Finally, we highlight the potential to exploit dark matter-induced defects as a novel detection channel, enabled by the introduction of new states within the electronic band gap.

hep-ph

Quenching factors for Na recoils as a function of Tl dopant concentrations in NaI(Tl) crystals

Thallium-doped sodium iodide (NaI(Tl)) scintillation detectors play an important role in the field of direct dark matter (DM) searches. The DAMA/LIBRA experiment stands out for its reported observation of an annually modulating DM-like signal, which is in direct contrast with other results. To accurately calibrate the energies of nuclear recoil signals with electron recoils, precise measurements of the quenching factor of the NaI(Tl) crystals are essential, as the two processes have different scintillation light yield. In this article, we present results of a systematic study carried out by the COSINUS collaboration and Duke University to measure the quenching factor of sodium (Na) recoils as a function of nuclear recoil energy and for differing Thallium (Tl) dopant concentrations in the bulk crystal. Five ultrapure NaI(Tl) crystals, manufactured by the Shanghai Institute for Ceramics, were irradiated with a quasi-monoenergetic neutron beam at the Triangle Universities Nuclear Laboratory, North Carolina, USA. The quenching factor for low nuclear recoil energies of 5-26keV$_{nr}$ was extracted for all 5 crystals. A Tl-dependence could be deduced with a proportional response calibration schema using a $^{241}$Am source. However, this effect was not observed when using a low-energy calibration line from $^{133}$Ba.

physics.ins-det

The SWEET project: probing sugar crystals for direct dark matter searches

Several experiments searching for direct dark matter interactions aim to achieve unprecedented sensitivity to sub-GeV/c$^2$ dark matter masses through elastic scattering with nuclei in various target crystals at cryogenic temperatures. Hydrogen-rich materials, such as organic compounds, are promising candidates for the detection of sub-GeV/c$^2$ dark matter due to favourable kinematics. In this paper, we present for the first time results obtained with a sugar-based phonon detector employing sucrose crystals ($\mathbf{C_{12}H_{22}O_{11}}$), capable of particle detection with associated scintillation light.

physics.ins-det

Particle background characterization and prediction for the NUCLEUS reactor CE$\nu$NS experiment

NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CE$\nu$NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE$\nu$NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE$\nu$NS signal region of interest between 10 and 100 eV, a total particle background rate of $\sim$ 250 d$^{-1}$kg$^{-1}$keV$^{-1}$ is expected in the CaWO$_4$ target detectors. This corresponds to a signal-to-background ratio $\gtrsim$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE$\nu$NS.

physics.ins-det

Description of CRESST-II and CRESST-III pulse shape data

A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data cleaning. Here, we describe the data set and how the trained models can be applied to new data. The data and models are available online.

physics.ins-det

Description of CRESST-III lithium aluminate data

Two detector modules with lithium aluminate targets were operated in the CRESST underground setup between February and June 2021. The data collected in this period was used to set the currently strongest cross-section upper limits on the spin-dependent interaction of dark matter (DM) with protons and neutrons for the mass region between 0.25 and 1.5 GeV/c$^2$. The data are available online. In this document, we describe how the data set should be used to reproduce our dark matter results.

hep-ex

Commissioning of the NUCLEUS Experiment at the Technical University of Munich

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO$_4$ targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW$_{\text{th}}$ reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.

hep-ex

COSINUS -- a model-independent challenge of the DAMA/LIBRA dark matter claim with cryogenic NaI detectors operated in a new low-background facility

Low-temperature detectors are a powerful technology for dark matter search, offering excellent energy resolution and low energy thresholds. COSINUS is the only experiment that combines scintillating sodium iodide (NaI) crystals with an additional phonon readout at cryogenic temperatures, using superconducting sensors (remoTES), alongside the conventional scintillation light signal. Via the simultaneous phonon and scintillation light detection, a unique event-by-event particle identification is enabled. This dual-channel approach allows for a model-independent cross-check of the long-standing DAMA/LIBRA signal with a moderate exposure of a few hundred kg d, while completely avoiding key systematic uncertainties inherent to scintillation-only NaI-based searches. COSINUS built and commissioned a dedicated low-background cryogenic facility at the LNGS underground laboratories. Data taking with eight NaI detector modules (COSINUS1$\pi$ Run1) is planned to begin in late 2025.

physics.ins-det

Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al$_{2}$O$_{3}$ crystal in CRESST-III

The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observation of a peak at (1113.6$^{+6.5}_{-6.5}$)$\,$eV in the data of an Al$_{2}$O$_{3}$ crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this mono-energetic peak to the radiative capture of thermal neutrons on $^{27}$Al and the subsequent de-excitation via single $\gamma$-emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al$_{2}$O$_{3}$ detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.

physics.ins-det

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677\,eV to 6.5\,keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).

physics.ins-det