Cell-based VSC Analysis Methodology: From Graph Laplacian to Converter Degrees of Freedom

Power-electronics-based converters are being considerably employed through the power system to interconnect multiple heterogeneous electrical layers. Furthermore, the intrinsic versatility to play with the converter network topology is widely exploited to accommodate a certain number of terminals and ports according with the specific application. On this regard, several converter arrangements can be encountered in power applications. Moreover, to properly establish both the operation and the control, the so-called degrees of freedom (DOFs) need to be assessed per each converter topology. On this matter, similarly to the well-known Clarke transformation, which clearly reveals the DOFs for the star-based topology system, further similar transformations can be achieved to depict the independent set of variables characterizing a certain converter structure. Referring to the cell-based class of Voltage Source Converter (VSC) topologies, including Modular Multilevel Converter (MMC); this article proposes a general methodology to determine the change of variable matrix transformation for several converter arrangements which are related to complete bi-partite and multi-partite graphs. The methodology lies in the graph Laplacian spectral analysis, which remarks the structural normal modes at the converter points of connections. Furthermore, for a complete characterization, the instantaneous power patterns formulations, based on the DOFs, are also introduced.

eess.SY↗

Data-Driven Decision Making for Enhancing Small-Signal Stability in Hybrid AC/DC Grids Through Converter Control Role Assignment

Hybrid AC/DC transmission grids incorporate Modular Multilevel Converters functioning as Interconnecting Power Converters (IPCs). The control role assigned to each converter significantly influences grid dynamics. Traditionally, these converters operate with static control roles, but recent studies have proposed scheduling their roles based on day-ahead forecasts to enhance stability performance. However, in systems with high renewable energy penetration, forecast deviations can render scheduled control assignments suboptimal or even lead to instability. To address this challenge, this work proposes an online scheduling recalculation algorithm that dynamically adapts IPC control roles during system operation. The approach leverages a data-driven multi-criteria decision-making framework, integrating surrogate models of conventional small-signal stability analysis tools to enable a fast computation of system stability and stability performance indicators.

eess.SY↗

A Dynamic Similarity Index for Assessing Voltage Source Behaviour in Power Systems

Due to the fundamental transition to a power electronic dominated power system, the increasing diversity of dynamic elements underscores the need to assess their similarity to mature electrical engineering models. This article addresses the concept of the Dynamic Similarity Index (DSI) for its use in, power electronics-dominated networks. The DSI is a multipurpose tool developed to be used by different stakeholders (e.g., converter manufacturers and system operators). Such an index is calculated per frequency, which serves to anticipate potential differences in particular frequency ranges of interest between the model under study and the reference model. Within the scope of this study, the dynamic similarity of inverter-based generators to an ideal voltage source behind an impedance is assessed, due to the relevance of this fundamental circuit in the representation of generation units in power system studies. The article presents two potential applications based on this mathematical framework. First, for manufacturers to evaluate control performance compared to a reference model and second, it enables operators to diagnose buses with voltage vulnerability based on a user-defined reference Short-Circuit Ratio (SCR) value. The DSI results for these two case studies are validated using Matlab Simulink simulations.

eess.SY↗

Dual-Port Grid-Forming Interconnecting Power Converters in Hybrid AC/DC Grids

Interconnecting power converters (IPC) are the main elements enabling the interconnection of multiple high-voltage alternating current (HVAC) and high-voltage direct current (HVDC) subgrids. These converters can be classified either as grid-forming or grid-following. These roles can be assigned to both ac and dc terminals. This work compares state-of-the-art single-port grid-forming and grid-following control schemes with a dual-port grid-forming control scheme, which can simultaneously form a stable voltage on the ac and the dc sides. The dual-port grid-forming small-signal stability and dynamic behavior under fluctuations in the power flow are studied and compared against state-of-the-art control architectures. Moreover, the dual-port control scheme is validated and tested on a down-scaled laboratory platform with several transient events.

eess.SY↗

Exploring Wavelet Transformations for Deep Learning-based Machine Condition Diagnosis

Deep learning (DL) strategies have recently been utilized to diagnose motor faults by simply analyzing motor phase current signals, offering a less costly and non-intrusive alternative to vibration sensors. This research transforms these time-series current signals into time-frequency 2D representations via Wavelet Transform (WT). The dataset for motor current signals includes 3,750 data points across five categories: one representing normal conditions and four representing artificially induced faults, each under five different load conditions: 0, 25, 50, 75, and 100%. The study employs five WT-based techniques: WT-Amor, WT-Bump, WT-Morse, WSST-Amor, and WSST-Bump. Subsequently, five DL models adopting prior Convolutional Neural Network (CNN) architecture were developed and tested using the transformed 2D plots from each method. The DL models for WT-Amor, WT-Bump, and WT-Morse showed remarkable effectiveness with peak model accuracy of 90.93, 89.20, and 93.73%, respectively, surpassing previous 2D-image-based methods that recorded accuracy of 80.25, 74.80, and 82.80% respectively using the identical dataset and validation protocol. Notably, the WT-Morse approach slightly exceeded the formerly highest ML technique, achieving a 93.20% accuracy. However, the two WSST methods that utilized synchrosqueezing techniques faced difficulty accurately classifying motor faults. The performance of Wavelet-based deep learning methods offers a compelling alternative for machine condition monitoring.

eess.SP↗

Deep Learning-based Machine Condition Diagnosis using Short-time Fourier Transformation Variants

In motor condition diagnosis, electrical current signature serves as an alternative feature to vibration-based sensor data, which is a more expensive and invasive method. Machine learning (ML) techniques have been emerging in diagnosing motor conditions using only motor phase current signals. This study converts time-series motor current signals to time-frequency 2D plots using Short-time Fourier Transform (STFT) methods. The motor current signal dataset consists of 3,750 sample points with five classes - one healthy and four synthetically-applied motor fault conditions, and with five loading conditions: 0, 25, 50, 75, and 100%. Five transformation methods are used on the dataset: non-overlap and overlap STFTs, non-overlap and overlap realigned STFTs, and synchrosqueezed STFT. Then, deep learning (DL) models based on the previous Convolutional Neural Network (CNN) architecture are trained and validated from generated plots of each method. The DL models of overlap-STFT, overlap R-STFT, non-overlap STFT, non-overlap R-STFT, and synchrosqueezed-STFT performed exceptionally with an average accuracy of 97.65, 96.03, 96.08, 96.32, and 88.27%, respectively. Four methods outperformed the previous best ML method with 93.20% accuracy, while all five outperformed previous 2D-plot-based methods with accuracy of 80.25, 74.80, and 82.80%, respectively, using the same dataset, same DL architecture, and validation steps.

eess.SP↗

Power Oscillation Damping Controllers for Grid-Forming Power Converters in Modern PowerSystems

Inter-area oscillations have been extensively studied in conventional power systems dominated by synchronous machines, as well as methods to mitigate them. Several publications have addressed Power Oscillation Damping (POD) controllers in grid-following voltage source converters (GFOL). However, the performance of POD controllers for Grid-Forming voltage source converters (GFOR) in modern power systems with increased penetration of power electronics requires further investigation. This paper investigates the performance of GFORs and supplementary POD controllers in the damping of electromechanical oscillations in modern power systems. This paper proposes POD controllers in GFORs by supplementary modulation of active- and reactive-power injections of the converter and both simultaneously (POD- P, POD-Q and POD-PQ, respectively). The proposed POD controllers use the frequency imposed by the GFOR as the input signal, which has a simple implementation and it eliminates the need for additional measurements. Eigenvalue-sensitivity methods using a synthetic test system are applied to the design of POD controllers in GFORs, which is useful when limited information of the power system is available. This paper demonstrates the effectiveness of POD controllers in GFOR converters to damp electromechanical oscillations, by small-signal stability analysis and non-linear time-domain simulations in a small test system and in a large-scale power system.

eess.SY↗

Dynamic Ancillary Services: From Grid Codes to Transfer Function-Based Converter Control

Conventional grid-code specifications for dynamic ancillary services provision such as fast frequency and voltage regulation are typically defined by means of piece-wise linear step-response capability curves in the time domain. However, although the specification of such time-domain curves is straightforward, their practical implementation in a converter-based generation system is not immediate, and no customary methods have been developed yet. In this paper, we thus propose a systematic approach for the practical implementation of piece-wise linear time-domain curves to provide dynamic ancillary services by converter-based generation systems, while ensuring grid-code and device-level requirements to be reliably satisfied. Namely, we translate the piece-wise linear time-domain curves for active and reactive power provision in response to a frequency and voltage step change into a desired rational parametric transfer function in the frequency domain, which defines a dynamic response behavior to be realized by the converter. The obtained transfer function can be easily implemented e.g. via a PI-based matching control in the power loop of standard converter control architectures. We demonstrate the performance of our method in numerical grid-code compliance tests, and reveal its superiority over classical droop and virtual inertia schemes which may not satisfy the grid codes due to their structural limitations.

eess.SY↗

Optimal Dynamic Ancillary Services Provision Based on Local Power Grid Perception

In this paper, we propose a systematic closed-loop approach to provide optimal dynamic ancillary services with converter-interfaced generation systems based on local power grid perception. In particular, we structurally encode dynamic ancillary services such as fast frequency and voltage regulation in the form of a parametric transfer function matrix, which includes several parameters to define a set of different feasible response behaviors, among which we aim to find the optimal one to be realized by the converter system. Our approach is based on a so-called "perceive-and-optimize" (P&O) strategy: First, we identify a grid dynamic equivalent at the interconnection terminals of the converter system. Second, we consider the closed-loop interconnection of the identified grid equivalent and the parametric transfer function matrix, which we optimize for the set of transfer function parameters, resulting in a stable and optimal closed-loop performance for ancillary services provision. In the process, we ensure that grid-code and device-level requirements are satisfied. Finally, we demonstrate the effectiveness of our approach in different numerical case studies based on a modified Kundur two-area test system.

eess.SY↗

How Many Grid-Forming Converters Do We Need? A Perspective From Small Signal Stability and Power Grid Strength

Grid-forming (GFM) control has been considered a promising solution for accommodating large-scale power electronics converters into modern power grids thanks to its grid-friendly dynamics, in particular, voltage source behavior on the AC side. The voltage source behavior of GFM converters can provide voltage support for the power grid, and therefore enhance the power grid (voltage) strength. However, grid-following (GFL) converters can also perform constant AC voltage magnitude control by properly regulating their reactive current, which may also behave like a voltage source. Currently, it still remains unclear what are the essential differences between the voltage source behaviors of GFL and GFM converters, and which type of voltage source behavior can enhance the power grid strength. In this paper, we will demonstrate that only GFM converters can provide effective voltage source behavior and enhance the power grid strength in terms of small signal dynamics. Based on our analysis, we further study the problem of how to configure GFM converters in the grid and how many GFM converters we will need. We investigate how the capacity ratio between GFM and GFL converters affects the equivalent power grid strength and thus the small signal stability of the system. We give guidelines on how to choose this ratio to achieve a desired stability margin. We validate our analysis using high-fidelity simulations.

eess.SY↗

Grid-Forming and Spatially Distributed Control Design of Dynamic Virtual Power Plants

We present a novel grid-forming control design approach for dynamic virtual power plants (DVPP). We consider a group of heterogeneous grid-forming distributed energy resources (DER) which collectively provide desired dynamic ancillary services, such as fast frequency and voltage control. To achieve that, we study the nontrivial aggregation of grid-forming DERs to establish the DVPP, and employ an adaptive divide-and-conquer strategy that disaggregates the desired control specifications of the aggregate DVPP via adaptive dynamic participation factors to obtain local desired behaviors of each DER. We then design local controllers at the DER level to realize these local desired behaviors. In the process, physical and engineered limits of each DER are taken into account. We extend the proposed approach to make it also compatible with grid-following DER controls, thereby establishing the concept of so-called hybrid DVPPs. Furthermore, we generalize the DVPP design to spatially dispersed DER locations in power grids with different voltage levels and R/X ratios. Finally, the DVPP control performance is verified via numerical case studies in the IEEE nine-bus transmission grid with an interconnected medium voltage distribution grid.

eess.SY↗

MIMO Grid Impedance Identification of Three-Phase Power Systems: Parametric vs. Nonparametric Approaches

A fast and accurate grid impedance measurement of three-phase power systems is crucial for online assessment of power system stability and adaptive control of grid-connected converters. Existing grid impedance measurement approaches typically rely on pointwise sinusoidal injections or sequential wideband perturbations to identify a nonparametric grid impedance curve via fast Fourier computations in the frequency domain. This is not only time-consuming, but also inaccurate during time-varying grid conditions, while on top of that, the identified nonparametric model cannot be immediately used for stability analysis or control design. To tackle these problems, we propose to use parametric system identification techniques (e.g., prediction error or subspace methods) to obtain a parametric impedance model directly from time-domain current and voltage data. Our approach relies on injecting wideband excitation signals in the converter's controller and allows to accurately identify the grid impedance in closed loop within one injection and measurement cycle. Even though the underlying parametric system identification techniques are well-studied in general, their utilization in a grid impedance identification setup poses specific challenges, is vastly underexplored, and has not gained adequate attention in urgent and timely power systems applications. To this end, we demonstrate in numerical experiments how the proposed parametric approach can accomplish a significant improvement compared to prevalent nonparametric methods.

eess.SY↗

Control Design of Dynamic Virtual Power Plants: An Adaptive Divide-and-Conquer Approach

In this paper, we present a novel control approach for dynamic virtual power plants (DVPPs). In particular, we consider a group of heterogeneous distributed energy resources (DERs) which collectively provide desired dynamic ancillary services such as fast frequency and voltage control. Our control approach relies on an adaptive divide-and-conquer strategy: first, we disaggregate the desired frequency and voltage control specifications of the aggregate DVPP via adaptive dynamic participation matrices (ADPMs) to obtain the desired local behavior for each device. Second, we design local linear parameter-varying (LPV) $\mathcal{H}_\infty$ controllers to optimally match this local behaviors. In the process, the control design also incorporates the physical and engineered limits of each DVPP device. Furthermore, our adaptive control design can properly respond to fluctuating device capacities, and thus include weather-driven DERs into the DVPP setup. Finally, we demonstrate the effectiveness of our control strategy in a case study based on the IEEE nine-bus system.

eess.SY↗

An Effective Methodology for Short-Circuit Calculation of Power Systems Dominated by Power Electronics Converters Considering Unbalanced Voltage Conditions and Converter Limits

This paper deals with the challenge of short-circuit calculation for power systems dominated by power electronics converters. A novel methodology has been presented to identify short-circuit equilibrium point of the studied system considering the operation and limitations of power converters. The studied system has been modeled with an element-based steady-state formulation. In particular, the governing equations implemented on converter control, which involve a specific control mode and various potential current-saturation states, are included. Then, an effective and efficient approach has been proposed to identify the short-circuit equilibrium points that satisfies converters limitations. Numerical case studies with VSCs show that the proposed methodology can identify the short-circuit equilibrium point efficiently and accurately with different types and depths of short-circuit fault. The short-circuit calculation results have been validated with dynamic simulations.

eess.SY↗

On Power Control of Grid-Forming Converters: Modeling, Controllability, and Full-State Feedback Design

The popular single-input single-output control structures and classic design methods (e.g., root locus analysis) for the power control of grid-forming converters have limitations in applying to different line characteristics and providing favorable performance. This paper studies the grid-forming converter power loops from the perspective of multi-input multi-output systems. First, the error dynamics associated with power control loops (error-based state-space model) are derived while taking into account the natural dynamical coupling terms of the power converter models. Thereafter, the controllability Gramian of the grid-forming converter power loops is studied. Last, a full-state feedback control design using only the local measurements is applied. By this way, the eigenvalues of the system can be arbitrarily placed in the timescale of power loops based on predefined time-domain specifications. A step-by-step construction and design procedure of the power control of grid-forming converters is also given. The analysis and proposed method are verified by experimental results.

eess.SY↗

Grid-Forming Loads: Can the loads be in charge of forming the grid in modern power systems?

Modern power systems are facing the tremendous challenge of integrating vast amounts of variable (non-dispatchable) renewable generation capacity, such as solar photovoltaic or wind power. In this context, the required power system flexibility needs to be allocated in other units that can include energy storage, demand management or providing reserve from renewables curtailing the output power. The present paper proposes the new concept of grid-forming load, which can be considered a totally flexible concept of demand. The concept is not only ensuring the load is supporting the grid stability by adapting the load to the overall system balancing, but also ensures that the load is actually contributing to form the grid and to provide synchronization power to the overall system. In this sense, the new concept allows running a system powered only by renewables operating at maximum power (or operator defined set-point) in grid-following mode, while the overall system control is ubicated in the demand side. This is an important change of paradigm as it considers that all the flexibility, synchronism and stability provision is on the demand side. This concept can applied either to isolated systems or also to future power systems, where millions of loads steer the power system while the renewables are operating at full power. The paper proposes the concept, suggests possible control implementations of the grid-forming load and analyses the concept in four simulation case studies.

eess.SY↗

Passivity-based design and analysis of phase-locked loops

We consider a grid-connected voltage source converter (VSC) and address the problem of estimating the grid angle and frequency, information that is essential for an appropriate operation of the converter. We design phase-locked loop (PLL) algorithms with guaranteed stability properties, under the assumption that the grid is characterized by relatively high short-circuit-ratio (SCR) and inertia. In particular we derive, using passivity arguments, generalization of the conventional synchronous reference frame (SRF) and arctangent (ATAN) PLL, which are the standard solutions in power applications. The analysis is further extended to the case of connection of the VSC to a low-inertia grid, ensuring robustness of the algorithms in case of frequency variations. The results are validated on a benchmark including the grid, the VSC and related controllers.

eess.SY↗

Dual-port grid-forming control of MMCs and its applications to grids of grids

This work focuses on grid-forming (GFM) control of Interconnecting Power Converters (IPCs) that are used to interconnect multiple HVAC and HVDC subgrids to form a grid of grids. We introduce the concept of dual-port GFM control that leverages the ability of Modular Multilevel Converters (MMCs) to simultaneously form its AC and DC terminal voltage and present two dual-port GFM MMC controls. We provide analytical results and high-fidelity simulations that demonstrate that (i) dual-port GFM control is more resilient to contingencies (i.e., line and generator outages) than state-of-the-art single-port GFM control, and (ii) unlike single-port GFM control, dual-port GFM control does not require assigning grid-forming and grid-following (GFL) roles to the IPC terminals in grids of grids. Finally, we provide an in-depth discussion and comparison of single-port GFM control and the proposed dual-port GFM controls.

eess.SY↗