arXiv Science⌕ Search

arXiv subjects

Christos Bergeles

Publications and source records attributed to Christos Bergeles.

At least 19 recordsLinked to original sources

Clinician-AI Collaboration in Endovascular Neurointerventions: In-Vitro User Study of Copilot Assistance Modes for Robotic Navigation Across the Autonomy Spectrum

Mechanical thrombectomy (MT) is an effective treatment for acute ischemic stroke, yet access remains limited by the availability of neurointerventional expertise. Telerobotic and AI-assisted systems may help address this challenge, but it remains unclear how clinicians interact with different levels of autonomy and how autonomous navigation systems perform in realistic environments. This work introduces Copilot Assistance Modes (CAMs), a framework for clinician-AI collaboration in robotic endovascular navigation spanning the autonomy spectrum from manual operation to full autonomy. In the first in-vitro user study comparing clinician-AI collaboration strategies, 11 experts and two students evaluated six navigation modes in a patient-specific vascular phantom. Objective performance metrics were combined with subjective assessments, including workload and usability. Autonomous performance was additionally evaluated both in silico and in vitro to investigate sim-to-real transfer. Hands-on manual navigation achieved the strongest overall performance (100% success). While fully autonomous navigation achieved 81% success in simulation, performance dropped to 23% in vitro. In contrast, several clinician-AI shared-autonomy modes achieved success rates of 92-97%, approximately four times higher than full autonomy and comparable to direct robotic control (95%), demonstrating mitigation of sim-to-real domain shift through clinician-AI collaboration. Among the evaluated AI-driven approaches, user-directed task delegation and rotational shared control demonstrated the most favorable balance between performance and clinician acceptance. These findings suggest that effective clinician-AI collaboration and allocation of control authority may currently be more important for reliable robotic neurointerventional navigation than increasing autonomy alone.

cs.RO↗

Longitudinal retinal imaging and auxiliary tasks for discrete-time survival prediction of referable diabetic retinopathy and maculopathy: a retrospective cohort study

Deep learning can predict progression to referable diabetic retinopathy (rDR) and referable maculopathy (rM) from screening photographs, but existing models ignore the prior images that screening programmes hold. We assessed whether multi-visit (MV) images and auxiliary objectives that model the future visit improve prognostic prediction. In this retrospective cohort study of macula-centred photographs from the South-East London Diabetic Eye Screening Programme (UK), eyes without referable disease at baseline and with a follow-up at 20-28 months were split into development (72,559 eyes, 36,648 patients) and test (17,917 eyes, 9,071 patients) sets. A time-aware discrete-time survival model predicted incident rDR (R2 or R3), rM (M1), or either (rDR/rM). We compared baseline-only input with up to three visits (MV), alone or with auxiliary supervision of future-visit age (MV+age) or future-visit latent prediction (MV+latent), using the AUROC of 28-month cumulative risk and paired DeLong tests with Benjamini-Hochberg correction. In the test set, 308 eyes (1.7%) developed rDR/rM, 58 (0.3%) rDR, and 275 (1.5%) rM. MV images increased the AUROC for rDR/rM from 0.749 to 0.786 (+0.037, 95% CI 0.012-0.061; q=0.011) and for rM from 0.749 to 0.788 (+0.039, 0.013-0.065; q=0.010). Auxiliary objectives did not improve MV model performance. In eyes with two or three visits, prior visits accounted for 30-38% of positive Grad-CAM attributions. Prior screening images improved prediction of incident maculopathy and the composite rDR/rM outcome, with gains driven by longitudinal images, not auxiliary supervision. External validation and prospective studies are required before the deployment of models to individualise screening.

eess.IV↗

High-Precision RCM Motion for Ophthalmic Robotics via Hierarchical QP Control and Authority-Guided Recovery Planning

General-purpose manipulators can position ophthalmic instruments under a software Remote Centre of Motion (RCM). However, at some reachable configurations that are nonsingular for the tip task alone, the RCM and tip-tracking objectives conflict and the servo oscillates. We formalise this failure as a constraint-induced task singularity: the RCM-projected tip Jacobian loses rank while the unprojected tip Jacobian stays well conditioned. Thus, the effective tip authority collapses although the target remains reachable. We present a high-precision RCM servo architecture with built-in singularity recovery: for each commanded target, an authority-guided planner selects a well-conditioned arm configuration that reaches it and plans an RCM-consistent route, executed by a fixed hierarchical-QP controller. On a 200-scenario kinematic benchmark, the complete nominal-and-recovery protocol reaches 128/128 near-singular targets and 71/72 near-joint-limit targets (100% and 99%, respectively), with the software-RCM residual below 0.142 mm. On a physical 6-DOF arm it executes across four RCM entry points, with a worst-case kinematically reconstructed RCM residual of 178 μm and a median tip-regulation error of 32μm, within the 200μm control requirement adopted for the ophthalmic task.

cs.RO↗

Learning From a Steady Hand: A Weakly Supervised Agent for Robot Assistance under Microscopy

This paper rethinks steady-hand robotic manipulation by using a weakly supervised framework that fuses calibration-aware perception with admittance control. Unlike conventional automation that relies on labor-intensive 2D labeling, our framework leverages reusable warm-up trajectories to extract implicit spatial information, thereby achieving calibration-aware, depth-resolved perception without the need for external fiducials or frame-by-frame manual depth annotation. By explicitly characterizing residuals from observation and calibration models, the system establishes a task-space error budget from recorded warm-ups. Under the evaluated laboratory conditions, the recorded trajectories yielded an empirical lateral error level of approximately 49μm and a conservative axial error estimate of approximately 291 μm during large in-plane moves. In a within-subject user study (N=8), the learned agent reduces overall NASA-TLX workload by 77.1% relative to the simple steady-hand assistance baseline. Together, these results demonstrate successful closed-loop micromanipulation and reduced subjective workload under the evaluated laboratory conditions, without external fiducials or frame-by-frame manual depth annotation, supporting the proposed approach as a framework for microscope-guided robotic assistance.

cs.RO↗

Hydra: Marker-Free RGB-D Hand-Eye Calibration

This work presents an RGB-D imaging-based approach to marker-free hand-eye calibration using a novel implementation of the iterative closest point (ICP) algorithm with a robust point-to-plane (PTP) objective formulated on a Lie algebra. Its applicability is demonstrated through comprehensive experiments using three well known serial manipulators and two RGB-D cameras. With only three randomly chosen robot configurations, our approach achieves approximately 90% successful calibrations, demonstrating 2-3x higher convergence rates to the global optimum compared to both marker-based and marker-free baselines. We also report 2 orders of magnitude faster convergence time (0.8 +/- 0.4 s) for 9 robot configurations over other marker-free methods. Our method exhibits significantly improved accuracy (5 mm in task space) over classical approaches (7 mm in task space) whilst being marker-free. The benchmarking dataset and code are open sourced under Apache 2.0 License, and a ROS 2 integration with robot abstraction is provided to facilitate deployment.

cs.RO↗

Progressive Experience Fusion for Multi-Task World Model Control in Endovascular Navigation

Autonomous endovascular navigation could support the delivery of mechanical thrombectomy to underserved areas, but controllers must navigate long, multi-stage paths across varying vascular anatomies. This study investigates Progressive Experience Fusion (PEF) to train a multi-task TD-MPC2 controller. We additionally evaluate a heuristic that changes the Model Predictive Path Integral planning horizon using residual action-sequence dispersion, and fine-tuning in a patient-specific simulation. Across five subtasks in ten known training anatomies with held-out targets, PEF achieved a mean success rate of 74%, compared with 37% for Soft Actor-Critic (p < 0.001) and 65% for base TD-MPC2 (p = 0.053). A PEF controller with adaptive-horizon planning trained on 30 vasculatures achieved a mean success rate of 90% in ten held-out vasculatures. The PEF agent successfully transferred to an unseen in vitro stroke patient vasculature under fluoroscopy, achieving a mean path ratio improvement from 63% to 80% with fine-tuning (p < 0.001), following 40x103 fine-tuning steps (corresponding to approximately 107 min of clinical inter-hospital transfer time). This work represents a proof of concept for multi-vasculature training and patient-specific adaptation, while further validation is required before clinical deployment.

cs.RO↗

Eversion-based robots can enable safe access,steering and endoscopic imaging within the spinal subarachnoid space

Safe navigation within the spinal subarachnoid space is constrained by its narrow, compliant, and delicate anatomy. Conventional catheters and continuum robots rely on proximal pushing, generating friction and shear along the tissue device interface that limit distal controllability and increase the risk of neural injury. Here, we present a 2 mm diameter eversion-growing robotic platform that enables friction minimised extension and steering within the human spinal subarachnoid space, validated through computational modelling, phantom experiments, and intact human cadaver studies. The robot integrates a miniature endoscope for real time intrathecal visualisation and advances by pressure driven tip eversion, localising motion to the distal tip while minimising translational sliding of the deployed body. Phantom experiments demonstrated reductions of 65.2% in mean interaction force and 48.0% in peak interaction force compared with matched push-based insertion. Physics based modelling showed that eversion based growth redistributed tissue loading, reducing local stress concentrations and interfacial shear relative to conventional insertion. In an intact human cadaver, the system achieved 150 mm of controlled intrathecal extension with concurrent fluoroscopic and endoscopic visualisation, providing access across multiple vertebral levels from a standard lumbar entry point. Postprocedural laminectomy and durotomy revealed no observable macroscopic disruption of the dura mater or surrounding neural structures. These results provide the first mechanically characterised and multimodally validated demonstration of eversion-based robotic navigation in intact human spinal anatomy, establishing a quantitative and procedural foundation for future intrathecal interventions. Further validation in larger anatomical cohorts and under physiological conditions will be required before clinical translation.

cs.RO↗

Streamlining stereo differentiable rendering for marker-free real-time tracking of surgical robots

Purpose: Marker-based tracking of surgical robots is occlusion-prone in cluttered operating rooms. We evaluate stereo differentiable rendering for marker-free, real-time robot pose tracking, potentially improving safety, reducing setup time, and enabling multi-robot interaction. Methods: We extend the markerless pose estimation framework roboreg to online dynamic tracking via (i) sequential optimisation that propagates pose estimates across frames with motion-adaptive hyperparameter tuning, and (ii) CUDA stream parallelisation of segmentation and optimisation, combined with CUDA-graph accelerated segmentation. We evaluate on 38 unobstructed and 5 occluded displacement sequences with static start/end ground-truth calibrations and dynamic marker-based reference tracking. Results: We achieve real-time 1080p tracking at 30 fps (up from 14 fps for vanilla roboreg), matching the camera frame rate. Accuracy reaches 1.7 cm / 0.6 deg against static ground truth and 1.2 cm mean 3D error over 27,460 frames against the marker-based reference (1.53 cm over 1,242 occluded frames). Our method outperforms FoundationPose by 11% in dynamic estimation (63% under occlusion) and 250% in static estimation, with 6x faster inference. Conclusions: Stereo differentiable rendering enables real-time, high-resolution marker-free surgical robot tracking, on par with marker-based approaches and surpassing foundation-model baselines.

cs.RO↗

Geometric Workspace Analysis and Transmission-Aware Dynamics of a Serial Spherical Tool for Microsurgery

We present a kinematic and transmission-aware design framework for a serial spherical mechanism with an additional translational degree of freedom for microsurgery. The first contribution is an analytical workspace formulation that provides geometric insight into reachable motion and enables rapid selection of rotation axis orientations without numerical optimization. The second contribution is a dynamics-informed methodology for mechanisms driven by self-locking transmissions, supporting evaluation of torque requirements for a prescribed workspace geometry. The framework is accompanied by an open-source software package for friction identification and inverse dynamics analysis. Experiments on a purpose-built robotic tool for vitreoretinal surgery validate the predictive capability of the models and demonstrate their practical utility for engineering design.

cs.RO↗

Remote Teleoperation of Endovascular Intervention Robots: A Systematic Review

Remote robotic-assisted endovascular intervention offers a promising approach to reduce clinician radiation exposure and physical strain, while extending specialized vascular care to geographically distant regions. Despite advancements, teleoperated endovascular intervention remains underexplored, especially for time-sensitive interventions like mechanical thrombectomy for acute stroke. The aim of the current review was to determine the evidence regarding teleoperated endovascular robotic systems, covering technical feasibility, communication infrastructure, and clinical outcomes. The review further identified research gaps and future directions. Following PRISMA guidelines, 16 studies were included that met the inclusion criteria out of 2501 initial search results. We found that teleoperated catheters and guidewires, driven by mechanical or electromagnetic systems, can be navigated across distances up to 7000 km. With robust communication infrastructure, network latency remained within clinically acceptable limits (30-163 ms). Although initial outcomes highlighted 100% procedural success in small-scale human trials, most evidence stemmed from animal or phantom models. Overall, the findings suggest that teleoperated endovascular intervention can reduce occupational hazards, expand patient access to urgent procedures, and optimize resource allocation. Future research should be conducted in low and middle income countries to demonstrate broader geographical access. Ultimately, multi-center clinical trials are required to validate the safety, efficacy, and generalization in diverse clinical settings.

cs.RO↗

Toward Safe Autonomous Robotic Endovascular Interventions using World Models

Autonomous mechanical thrombectomy (MT) presents substantial challenges due to highly variable vascular geometries and the requirements for accurate, real-time control. While reinforcement learning (RL) has emerged as a promising paradigm for the automation of endovascular navigation, existing approaches often show limited robustness when faced with diverse patient anatomies or extended navigation horizons. In this work, we investigate a world-model-based framework for autonomous endovascular navigation built on TD-MPC2, a model-based RL method that integrates planning and learned dynamics. We evaluate a TD-MPC2 agent trained on multiple navigation tasks across hold out patient-specific vasculatures and benchmark its performance against the state-of-the-art Soft Actor-Critic (SAC) algorithm agent. Both approaches are further validated in vitro using patient-specific vascular phantoms under fluoroscopic guidance. In simulation, TD-MPC2 demonstrates a significantly higher mean success rate than SAC (58% vs. 36%, p < 0.001), and mean tip contact forces of 0.15 N, well below the proposed 1.5 N vessel rupture threshold. Mean success rates for TD-MPC2 (68%) were comparable to SAC (60%) in vitro, but TD-MPC2 achieved superior path ratios (p = 0.017) at the cost of longer procedure times (p < 0.001). Together, these results provide the first demonstration of autonomous MT navigation validated across both hold out in silico data and fluoroscopy-guided in vitro experiments, highlighting the promise of world models for safe and generalizable AI-assisted endovascular interventions.

cs.RO↗

ROBUST-MIPS: A Combined Skeletal Pose and Instance Segmentation Dataset for Laparoscopic Surgical Instruments

Localisation of surgical tools constitutes a foundational building block for computer-assisted interventional technologies. Works in this field typically focus on training deep learning models to perform segmentation tasks. Performance of learning-based approaches is limited by the availability of diverse annotated data. We argue that skeletal pose annotations are a more efficient annotation approach for surgical tools, striking a balance between richness of semantic information and ease of annotation, thus allowing for accelerated growth of available annotated data. To encourage adoption of this annotation style, we present, ROBUST-MIPS, a combined tool pose and tool instance segmentation dataset derived from the existing ROBUST-MIS dataset. Our enriched dataset facilitates the joint study of these two annotation styles and allow head-to-head comparison on various downstream tasks. To demonstrate the adequacy of pose annotations for surgical tool localisation, we set up a simple benchmark using popular pose estimation methods and observe high-quality results. To ease adoption, together with the dataset, we release our benchmark models and custom tool pose annotation software.

cs.CV↗

Toward AI Autonomous Navigation for Mechanical Thrombectomy using Hierarchical Modular Multi-agent Reinforcement Learning (HM-MARL)

Mechanical thrombectomy (MT) is typically the optimal treatment for acute ischemic stroke involving large vessel occlusions, but access is limited due to geographic and logistical barriers. Reinforcement learning (RL) shows promise in autonomous endovascular navigation, but generalization across 'long' navigation tasks remains challenging. We propose a Hierarchical Modular Multi-Agent Reinforcement Learning (HM-MARL) framework for autonomous two-device navigation in vitro, enabling efficient and generalizable navigation. HM-MARL was developed to autonomously navigate a guide catheter and guidewire from the femoral artery to the internal carotid artery (ICA). A modular multi-agent approach was used to decompose the complex navigation task into specialized subtasks, each trained using Soft Actor-Critic RL. The framework was validated in both in silico and in vitro testbeds to assess generalization and real-world feasibility. In silico, a single-vasculature model achieved 92-100% success rates on individual anatomies, while a multi-vasculature model achieved 56-80% across multiple patient anatomies. In vitro, both HM-MARL models successfully navigated 100% of trials from the femoral artery to the right common carotid artery and 80% to the right ICA but failed on the left-side vessel superhuman challenge due to the anatomy and catheter type used in navigation. This study presents the first demonstration of in vitro autonomous navigation in MT vasculature. While HM-MARL enables generalization across anatomies, the simulation-to-real transition introduces challenges. Future work will refine RL strategies using world models and validate performance on unseen in vitro data, advancing autonomous MT towards clinical translation.

cs.RO↗

Localising under the drape: proprioception in the era of distributed surgical robotic system

Despite their mechanical sophistication, surgical robots remain blind to their surroundings. This lack of spatial awareness causes collisions, system recoveries, and workflow disruptions, issues that will intensify with the introduction of distributed robots with independent interacting arms. Existing tracking systems rely on bulky infrared cameras and reflective markers, providing only limited views of the surgical scene and adding hardware burden in crowded operating rooms. We present a marker-free proprioception method that enables precise localisation of surgical robots under their sterile draping despite associated obstruction of visual cues. Our method solely relies on lightweight stereo-RGB cameras and novel transformer-based deep learning models. It builds on the largest multi-centre spatial robotic surgery dataset to date (1.4M self-annotated images from human cadaveric and preclinical in vivo studies). By tracking the entire robot and surgical scene, rather than individual markers, our approach provides a holistic view robust to occlusions, supporting surgical scene understanding and context-aware control. We demonstrate an example of potential clinical benefits during in vivo breathing compensation with access to tissue dynamics, unobservable under state of the art tracking, and accurately locate in multi-robot systems for future intelligent interaction. In addition, and compared with existing systems, our method eliminates markers and improves tracking visibility by 25%. To our knowledge, this is the first demonstration of marker-free proprioception for fully draped surgical robots, reducing setup complexity, enhancing safety, and paving the way toward modular and autonomous robotic surgery.

cs.RO↗

Motion-Boundary-Driven Unsupervised Surgical Instrument Segmentation in Low-Quality Optical Flow

Unsupervised video-based surgical instrument segmentation has the potential to accelerate the adoption of robot-assisted procedures by reducing the reliance on manual annotations. However, the generally low quality of optical flow in endoscopic footage poses a great challenge for unsupervised methods that rely heavily on motion cues. To overcome this limitation, we propose a novel approach that pinpoints motion boundaries, regions with abrupt flow changes, while selectively discarding frames with globally low-quality flow and adapting to varying motion patterns. Experiments on the EndoVis2017 VOS and EndoVis2017 Challenge datasets show that our method achieves mean Intersection-over-Union (mIoU) scores of 0.75 and 0.72, respectively, effectively alleviating the constraints imposed by suboptimal optical flow. This enables a more scalable and robust surgical instrument segmentation solution in clinical settings. The code will be publicly released.

cs.CV↗

A Generalized Modeling Approach to Liquid-driven Ballooning Membranes

Soft robotics is advancing the use of flexible materials for adaptable robotic systems. Membrane-actuated soft robots address the limitations of traditional soft robots by using pressurized, extensible membranes to achieve stable, large deformations, yet control and state estimation remain challenging due to their complex deformation dynamics. This paper presents a novel modeling approach for liquid-driven ballooning membranes, employing an ellipsoid approximation to model shape and stretch under planar deformation. Relying solely on intrinsic feedback from pressure data and controlled liquid volume, this approach enables accurate membrane state estimation. We demonstrate the effectiveness of the proposed model for ballooning membrane-based actuators by experimental validation, obtaining the indentation depth error of $RMSE_{h_2}=0.80\;$mm, which is $23\%$ of the indentation range and $6.67\%$ of the unindented actuator height range. For the force estimation, the error range is obtained to be $RMSE_{F}=0.15\;$N which is $10\%$ of the measured force range.

cs.RO↗

Evaluating Robotic Approach Techniques for the Insertion of a Straight Instrument into a Vitreoretinal Surgery Trocar

Advances in vitreoretinal robotic surgery enable precise techniques for gene therapies. This study evaluates three robotic approaches using the 7-DoF robotic arm for docking a micro-precise tool to a trocar: fully co-manipulated, hybrid co-manipulated/teleoperated, and hybrid with camera assistance. The fully co-manipulated approach was the fastest but had a 42% success rate. Hybrid methods showed higher success rates (91.6% and 100%) and completed tasks within 2 minutes. NASA Task Load Index (TLX) assessments indicated lower physical demand and effort for hybrid approaches.

cs.RO↗

ArcSin: Adaptive ranged cosine Similarity injected noise for Language-Driven Visual Tasks

"A data scientist is tasked with developing a low-cost surgical VQA system for a 2-month workshop. Due to data sensitivity, she collects 50 hours of surgical video from a hospital, requiring two months for privacy approvals. Privacy restrictions prevent uploading data to platforms like ChatGPT, so she assembles one annotator and a medical expert to manually create QA pairs. This process takes three weeks and costs over $10,000. The trained model provides accurate responses within the limited data scope but lacks broader generalizability, completing the project in 3 months." To simplify the challenges presented in the scenario above. In this paper, we replace the image input with text for Vision-language training. Inspired by prior noise injection methods to reduce modality gaps, we introduce Adaptive ranged cosine Similarity injected noise (ArcSin). First, we introduce an innovative adaptive noise scale that effectively generates the textual elements with more variability while preserving the original text feature's integrity. Second, a similarity pool strategy is employed, expanding the domain generalization potential by broadening the overall noise scale. This dual strategy effectively broadens the scope of the original domain while safeguarding content integrity. Our empirical results demonstrate that these models closely rival those trained on images in terms of performance. Specifically, our method exhibits substantial improvements over the previous state-of-the-art, achieving gains of 1.9 and 1.1 CIDEr points in S-Cap and M-Cap, respectively. Additionally, we observe increases of 0.5 percentage points (pp), 1.4 pp, and 1.4 pp in accuracy for VQA, VQA-E, and VE, respectively, pushing the boundaries of what is achievable within the constraints of image-trained model benchmarks.

cs.CV↗