arXiv ScienceSearch

arXiv subjects

B. Barrett

Publications and source records attributed to B. Barrett.

17 recordsLinked to original sources

Standalone optical frequency-offset locking electronics for atomic physics

We present a standalone frequency-offset locking system for controlling narrow-linewidth lasers using off-the-shelf electronic components. We lock two frequency-doubled 1560 nm lasers to a stable primary laser operating at 780 nm via their optical beat note. This radio-frequency beat note is fed through a broadband variable divider, a frequency-to-voltage converter, and a proportional-integrator controller to lock each follower laser to a tunable offset frequency relative to the primary. This architecture provides a large capture range ($> 1$ GHz), fast response times ($< 1$ ms), and high linearity. We achieve a frequency resolution of 1.9 kHz and a short-term fractional frequency instability $10^{-11}/\sqrt{\tau \rm (s)}$ at 780 nm without the need for a dedicated, precise clock reference. We perform high-resolution spectroscopy of cold $^{87}$Rb atoms to demonstrate the tunability and precision of our locking system. We designed the system to be modular and extensible, making it applicable to a wide variety of atomic physics experiments, including laser cooling, spectroscopy, and quantum sensing with atoms, ions, and molecules.

physics.atom-ph

Carrier-Suppressed Multiple Single-Sideband Laser Source for Atom Cooling and Interferometry

We present a new electro-optic modulation technique that enables a single laser diode to realize a cold-atom source and a quantum inertial sensor based on matter-wave interferometry. Using carrier-suppressed dual single-sideband modulation, an IQ modulator generates two optical sidebands from separate radio-frequency (rf) signals. These sidebands are controlled independently in frequency, phase, and power using standard rf components. Our laser source exhibits improved rejection of parasitic sidebands compared to those based on phase modulators, which generate large systematic shifts in atom interferometers. We measure the influence of residual laser lines on an atom-interferometric gravimeter and show agreement with a theoretical model. We estimate a reduction of the systematic shift by two orders of magnitude compared to previous architectures, and reach a long-term sensitivity of 15 ng on the gravitational acceleration with an interrogation time of only T = 20 ms. Finally, we characterize the performance of our integrated laser system, and show that it is suitable for mobile sensing applications including gravity surveys and inertial navigation.

physics.atom-ph

Separated Kaon Electroproduction Cross Section and the Kaon Form Factor from 6 GeV JLab Data

The $^{1}H$($e,e^\prime K^+$)$\Lambda$ reaction was studied as a function of the Mandelstam variable $-t$ using data from the E01-004 (FPI-2) and E93-018 experiments that were carried out in Hall C at the 6 GeV Jefferson Lab. The cross section was fully separated into longitudinal and transverse components, and two interference terms at four-momentum transfers $Q^2$ of 1.00, 1.36 and 2.07 GeV$^2$. The kaon form factor was extracted from the longitudinal cross section using the Regge model by Vanderhaeghen, Guidal, and Laget. The results establish the method, previously used successfully for pion analyses, for extracting the kaon form factor. Data from 12 GeV Jefferson Lab experiments are expected to have sufficient precision to distinguish between theoretical predictions, for example recent perturbative QCD calculations with modern parton distribution amplitudes. The leading-twist behavior for light mesons is predicted to set in for values of $Q^2$ between 5-10 GeV$^2$, which makes data in the few GeV regime particularly interesting. The $Q^2$ dependence at fixed $x$ and $-t$ of the longitudinal cross section we extracted seems consistent with the QCD factorization prediction within the experimental uncertainty.

nucl-ex

Generation of high-purity, low-temperature samples of $^{39}$K for applications in metrology

We present an all optical technique to prepare a sample of $^{39}$K in a magnetically-insensitive state with 95\% purity while maintaining a temperature of 6 $\mu$K. This versatile preparation scheme is particularly well suited to performing matter-wave interferometry with species exhibiting closely-separated hyperfine levels, such as the isotopes of lithium and potassium, and opens new possibilities for metrology with these atoms. We demonstrate the feasibility of such measurements by realizing an atomic gravimeter and a Ramsey-type spectrometer, both of which exhibit a state-of-the-art sensitivity for cold potassium.

physics.atom-ph

Studies of general relativity with quantum sensors

We present two projects aiming to probe key aspects of the theory of General Relativity with high-precision quantum sensors. These projects use cold-atom interferometry with the aim of measuring gravitational waves and testing the equivalence principle. To detect gravitational waves, a large multi-sensor demonstrator is currently under construction that will exploit correlations between three atom interferometers spread along a 200 m optical cavity. Similarly, a test of the weak equivalence principle is currently underway using a compact and mobile dual-species interferometer, which will serve as a prototype for future high-precision tests onboard an orbiting satellite. We present recent results and improvements related to both projects.

physics.atom-ph

Development of compact cold-atom sensors for inertial navigation

Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment---consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of $2.3 \times 10^{-4}\,g$ over a range of $\sim 0.1\,g$. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 $\mu$s.

physics.atom-ph

Inertial quantum sensors using light and matter

The past few decades have seen dramatic progress in our ability to manipulate and coherently control matter-waves. Although the duality between particles and waves has been well tested since de Broglie introduced the matter-wave analog of the optical wavelength in 1924, manipulating atoms with a level of coherence that enables one to use these properties for precision measurements has only become possible with our ability to produce atomic samples exhibiting temperatures of only a few millionths of a degree above absolute zero. Since the initial experiments a few decades ago, the field of atom optics has developed in many ways, with both fundamental and applied significance. The exquisite control of matter waves offers the prospect of a new generation of force sensors exhibiting unprecedented sensitivity and accuracy, for applications from navigation and geophysics to tests of general relativity. Thanks to the latest developments in this field, the first commercial products using this quantum technology are now available. In the future, our ability to create large coherent ensembles of atoms will allow us an even more precise control of the matter-wave and the ability to create highly entangled states for non-classical atom interferometry.

physics.atom-ph

Correlative methods for dual-species quantum tests of the weak equivalence principle

Matter-wave interferometers utilizing different isotopes or chemical elements intrinsically have different sensitivities, and the analysis tools available until now are insufficient for accurately estimating the atomic phase difference under many experimental conditions. In this work, we describe and demonstrate two new methods for extracting the differential phase between dual-species atom interferometers for precise tests of the weak equivalence principle. The first method is a generalized Bayesian analysis, which uses knowledge of the system noise to estimate the differential phase based on a statistical model. The second method utilizes a mechanical accelerometer to reconstruct single-sensor interference fringes based on measurements of the vibration-induced phase. An improved ellipse-fitting algorithm is also implemented as a third method for comparison. These analysis tools are investigated using both numerical simulations and experimental data from simultaneous $^{87}$Rb and $^{39}$K interferometers, and both new techniques are shown to produce bias-free estimates of the differential phase. We also report observations of phase correlations between atom interferometers composed of different chemical species. This correlation enables us to reject common-mode vibration noise by a factor of 730, and to make preliminary tests of the weak equivalence principle with a sensitivity of $1.6 \times 10^{-6}$ per measurement with an interrogation time of $T = 10$ ms. We study the level of vibration rejection by varying the temporal overlap between interferometers in a symmetric timing sequence. Finally, we discuss the limitations of the new analysis methods for future applications of differential atom interferometry.

physics.atom-ph

Separated Response Functions in Exclusive, Forward $\pi^{\pm}$ Electroproduction on Deuterium

Background: Measurements of forward exclusive meson production at different squared four-momenta of the exchanged virtual photon, $Q^2$, and at different four-momentum transfer, t, can be used to probe QCD's transition from meson-nucleon degrees of freedom at long distances to quark-gluon degrees of freedom at short scales. Ratios of separated response functions in $\pi^-$ and $\pi^+$ electroproduction are particularly informative. The ratio for transverse photons may allow this transition to be more easily observed, while the ratio for longitudinal photons provides a crucial verification of the assumed pole dominance, needed for reliable extraction of the pion form factor from electroproduction data. Method: Data were acquired with 2.6-5.2 GeV electron beams and the HMS+SOS spectrometers in Jefferson Lab Hall C, at central $Q^2$ values of 0.6, 1.0, 1.6 GeV$^2$ at W=1.95 GeV, and $Q^2$=2.45 GeV$^2$ at W=2.22 GeV. There was significant coverage in $\phi$ and $\epsilon$, which allowed separation of $\sigma_{L,T,LT,TT}$. Results: $\sigma_L$ shows a clear signature of the pion pole, with a sharp rise at small -t. In contrast, $\sigma_T$ is much flatter versus t. The longitudinal/transverse ratios evolve with $Q^2$ and t, and at the highest $Q^2$=2.45 GeV$^2$ show a slight enhancement for $\pi^-$ production compared to $\pi^+$. The $\pi^-/\pi^+$ ratio for transverse photons exhibits only a small $Q^2$-dependence, following a nearly universal curve with t, with a steep transition to a value of about 0.25, consistent with s-channel quark knockout. The $\sigma_{TT}/\sigma_T$ ratio also drops rapidly with $Q^2$, qualitatively consistent with s-channel helicity conservation. The $\pi^-/\pi^+$ ratio for longitudinal photons indicates a small isoscalar contamination at W=1.95 GeV, consistent with what was observed in our earlier determination of the pion form factor at these kinematics.

nucl-ex

Separated Response Function Ratios in Exclusive, Forward pi^{+/-} Electroproduction

The study of exclusive $\pi^{\pm}$ electroproduction on the nucleon, including separation of the various structure functions, is of interest for a number of reasons. The ratio $R_L=\sigma_L^{\pi^-}/\sigma_L^{\pi^+}$ is sensitive to isoscalar contamination to the dominant isovector pion exchange amplitude, which is the basis for the determination of the charged pion form factor from electroproduction data. A change in the value of $R_T=\sigma_T^{\pi^-}/\sigma_T^{\pi^+}$ from unity at small $-t$, to 1/4 at large $-t$, would suggest a transition from coupling to a (virtual) pion to coupling to individual quarks. Furthermore, the mentioned ratios may show an earlier approach to pQCD than the individual cross sections. We have performed the first complete separation of the four unpolarized electromagnetic structure functions above the dominant resonances in forward, exclusive $\pi^{\pm}$ electroproduction on the deuteron at central $Q^2$ values of 0.6, 1.0, 1.6 GeV$^2$ at $W$=1.95 GeV, and $Q^2=2.45$ GeV$^2$ at $W$=2.22 GeV. Here, we present the $L$ and $T$ cross sections, with emphasis on $R_L$ and $R_T$, and compare them with theoretical calculations. Results for the separated ratio $R_L$ indicate dominance of the pion-pole diagram at low $-t$, while results for $R_T$ are consistent with a transition between pion knockout and quark knockout mechanisms.

nucl-ex

Mobile and remote inertial sensing with atom interferometers

The past three decades have shown dramatic progress in the ability to manipulate and coherently control the motion of atoms. This exquisite control offers the prospect of a new generation of inertial sensors with unprecedented sensitivity and accuracy, which will be important for both fundamental and applied science. In this article, we review some of our recent results regarding the application of atom interferometry to inertial measurements using compact, mobile sensors. This includes some of the first interferometer measurements with cold $^{39}$K atoms, which is a major step toward achieving a transportable, dual-species interferometer with rubidium and potassium for equivalence principle tests. We also discuss future applications of this technology, such as remote sensing of geophysical effects, gravitational wave detection, and precise tests of the weak equivalence principle in Space.

physics.atom-ph

Demonstration of improved sensitivity of echo interferometers to gravitational acceleration

We have developed two configurations of an echo interferometer that rely on standing wave excitation of a laser-cooled sample of rubidium atoms that measures acceleration. For a two-pulse configuration, the interferometer signal is modulated at the recoil frequency and exhibits a sinusoidal frequency chirp as a function of pulse spacing. For a three-pulse stimulated echo configuration, the signal is observed without recoil modulation and exhibits a modulation at a single frequency. The three-pulse configuration is less sensitive to effects of vibrations and magnetic field curvature leading to a longer experimental timescale. For both configurations of the atom interferometer (AI), we show that a measurement of acceleration with a statistical precision of 0.5% can be realized by analyzing the shape of the echo envelope that has a temporal duration of a few microseconds. Using the two-pulse AI, we obtain measurements of acceleration that are statistically precise to 6 parts per million (ppm) on a 25 ms timescale. Using the three-pulse AI, we obtain measurements of acceleration that are statistically precise to 0.4 ppm on a timescale of 50 ms. A further statistical enhancement is achieved by analyzing the data across the echo envelope to improve the statistical precision to 75 parts per billion (ppb). We discuss methods for reducing prominent systematic effects due to a magnetized vacuum chamber and improving the signal-to-noise ratio. Simulations of both AI configurations with a timescale of 300 ms reached in a non-magnetic vacuum chamber suggest that an optimized experiment with improved vibration isolation and atoms selected in the mF = 0 state can result in measurements of g statistically precise to 0.3 pbb for the two-pulse AI and 0.6 ppb for the three-pulse AI.

physics.atom-ph

Measuring the atomic recoil frequency using a perturbative grating-echo atom interferometer

We describe progress toward a precise measurement of the recoil energy of an atom measured using a perturbative grating-echo atom interferometer (AI) that involves three standing-wave (sw) pulses. With this technique, a perturbing sw pulse is used to shift the phase of excited momentum states---producing a modulation in the contrast of the interference pattern. The signal exhibits narrow fringes that revive periodically at twice the two-photon recoil frequency, $2\omega_q$, as a function of the onset time of the pulse. Experiments are performed using samples of laser-cooled rubidium atoms with temperatures $\lesssim 5$ $\mu$K in a non-magnetic apparatus. We demonstrate a measurement of $\omega_q$ with a statistical uncertainty of 37 parts per $10^9$ (ppb) on a time scale of $\sim 45$ ms in 14 hours. Further statistical improvements are anticipated by extending this time scale and narrowing the signal fringe width. However, the total systematic uncertainty is estimated to be $\sim 6$ parts per $10^6$ (ppm). We describe methods of reducing these systematic errors.

physics.atom-ph

Atom interferometric techniques for measuring uniform magnetic field gradients and gravitational acceleration

We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of $^{85}$Rb with temperatures as low as 2.4 $\mu$K have been achieved in a new experimental apparatus with a well-controlled magnetic environment. We demonstrate interferometer signal lifetimes approaching the transit time limit in this system ($\sim 270$ ms), which is comparable to the timescale achieved by Raman interferometers. Using these long timescales, we experimentally investigate the influence of a homogeneous magnetic field gradient using two- and three-pulse interferometers, which enable us to sense changes in externally applied magnetic field gradients as small as $\sim 4 \times 10^{-5}$ G/cm. We also provide an improved theoretical description of signals generated by both interferometer configurations that accurately models experimental results. With this theory, absolute measurements of $B$-gradients at the level of $3 \times 10^{-4}$ G/cm are achieved. Finally, we contrast the suitability of the two- and three-pulse interferometers for precision measurements of the gravitational acceleration, $g$.

physics.atom-ph

Charged pion form factor between $Q^2$=0.60 and 2.45 GeV$^2$. I. Measurements of the cross section for the ${^1}$H($e,e'π^+$)$n$ reaction

Cross sections for the reaction ${^1}$H($e,e'π^+$)$n$ were measured in Hall C at Thomas Jefferson National Accelerator Facility (JLab) using the CEBAF high-intensity, continous electron beam in order to determine the charged pion form factor. Data were taken for central four-momentum transfers ranging from $Q^2$=0.60 to 2.45 GeV$^2$ at an invariant mass of the virtual photon-nucleon system of $W$=1.95 and 2.22 GeV. The measured cross sections were separated into the four structure functions $σ_L$, $σ_T$, $σ_{LT}$, and $σ_{TT}$. The various parts of the experimental setup and the analysis steps are described in detail, including the calibrations and systematic studies, which were needed to obtain high precision results. The different types of systematic uncertainties are also discussed. The results for the separated cross sections as a function of the Mandelstam variable $t$ at the different values of $Q^2$ are presented. Some global features of the data are discussed, and the data are compared with the results of some model calculations for the reaction ${^1}$H($e,e'π^+$)$n$.

nucl-ex

Charged pion form factor between Q^2=0.60 and 2.45 GeV^2. II. Determination of, and results for, the pion form factor

The charged pion form factor, Fpi(Q^2), is an important quantity which can be used to advance our knowledge of hadronic structure. However, the extraction of Fpi from data requires a model of the 1H(e,e'pi+)n reaction, and thus is inherently model dependent. Therefore, a detailed description of the extraction of the charged pion form factor from electroproduction data obtained recently at Jefferson Lab is presented, with particular focus given to the dominant uncertainties in this procedure. Results for Fpi are presented for Q^2=0.60-2.45 GeV^2. Above Q^2=1.5 GeV^2, the Fpi values are systematically below the monopole parameterization that describes the low Q^2 data used to determine the pion charge radius. The pion form factor can be calculated in a wide variety of theoretical approaches, and the experimental results are compared to a number of calculations. This comparison is helpful in understanding the role of soft versus hard contributions to hadronic structure in the intermediate Q^2 regime.

nucl-ex

Determination of the Charged Pion Form Factor at Q2=1.60 and 2.45 (GeV/c)2

The H(e,e'pi+)n cross section was measured at four-momentum transfers of Q2=1.60 and 2.45 GeV2 at an invariant mass of the photon nucleon system of W=2.22 GeV. The charged pion form factor (F_pi) was extracted from the data by comparing the separated longitudinal pion electroproduction cross section to a Regge model prediction in which F_pi is a free parameter. The results indicate that the pion form factor deviates from the charge-radius constrained monopole form at these values of Q2 by one sigma, but is still far from its perturbative Quantum Chromo-Dynamics prediction.

nucl-ex