arXiv ScienceSearch

arXiv · 1307.1902

Demonstration of improved sensitivity of echo interferometers to gravitational acceleration

Abstract

We have developed two configurations of an echo interferometer that rely on standing wave excitation of a laser-cooled sample of rubidium atoms that measures acceleration. For a two-pulse configuration, the interferometer signal is modulated at the recoil frequency and exhibits a sinusoidal frequency chirp as a function of pulse spacing. For a three-pulse stimulated echo configuration, the signal is observed without recoil modulation and exhibits a modulation at a single frequency. The three-pulse configuration is less sensitive to effects of vibrations and magnetic field curvature leading to a longer experimental timescale. For both configurations of the atom interferometer (AI), we show that a measurement of acceleration with a statistical precision of 0.5% can be realized by analyzing the shape of the echo envelope that has a temporal duration of a few microseconds. Using the two-pulse AI, we obtain measurements of acceleration that are statistically precise to 6 parts per million (ppm) on a 25 ms timescale. Using the three-pulse AI, we obtain measurements of acceleration that are statistically precise to 0.4 ppm on a timescale of 50 ms. A further statistical enhancement is achieved by analyzing the data across the echo envelope to improve the statistical precision to 75 parts per billion (ppb). We discuss methods for reducing prominent systematic effects due to a magnetized vacuum chamber and improving the signal-to-noise ratio. Simulations of both AI configurations with a timescale of 300 ms reached in a non-magnetic vacuum chamber suggest that an optimized experiment with improved vibration isolation and atoms selected in the mF = 0 state can result in measurements of g statistically precise to 0.3 pbb for the two-pulse AI and 0.6 ppb for the three-pulse AI.

Explore related subjects

Keep this discovery

BibTeXRIS

C. Mok, B. Barrett, A. Carew, R. Berthiaume, S. Beattie, A. Kumarakrishnan. 2013-07-07. Demonstration of improved sensitivity of echo interferometers to gravitational acceleration. https://doi.org/10.1103/physreva.88.023614

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Delay-engineered dynamical phases in a programmable non-Markovian spin oscillator

Non-Markovian dynamics offer a new route towards engineering non-equilibrium matter, where memory and feedback act as programmable resources for controlling order in time. Here we report the realization of a non-Markovian spin oscillator in a hot vapour $^{129}$Xe-Cs co-magnetometer with programmable feedback delay and gain. By tuning these parameters, we observe a hierarchy of dynamical phases, including time-crystalline response, nonlinear bifurcations, and frequency-comb formation. The measured spectra and phase boundaries are captured by linear stability analysis of delayed Bloch equations, revealing these phenomena as different manifestations of the same memory-induced instability structure. These results establish time-delayed feedback as a powerful strategy for controlling non-equilibrium phases, enabling quantum sensing, frequency referencing, and synchronization within a single spin-based platform.

physics.atom-ph

Non-stick vacuum wall collisions with a laser-coolable molecule

Molecular species that are suitable for direct laser cooling are typically considered lost or destroyed if they collide with an ambient temperature vacuum wall. Here, we study surface collisions with aluminum monofluoride (AlF), a laser-coolable molecule that survives this process with unusually high probability. We detect the outgoing AlF molecules from a single wall collision via Doppler-sensitive laser-induced fluorescence spectroscopy, using incoming supersonic (pulsed) and thermochemical (continuous) molecular beams. The angular, velocity and rovibrational level distributions of the outgoing molecules show near-complete thermalisation to the wall in a single collision event. We determine an upper limit to the surface residence time of about 5$~\mu$s, and by monitoring the decay in density of pulses of molecules loaded into a small storage volume, we deduce the surface sticking probability for different materials. For a siloxane-coated metallic surface, the sticking probability of AlF is about 0.015, allowing us to accumulate molecules from the thermochemical source into an ambient temperature storage vessel at densities near $10^{8}~$cm$^{-3}$. This provides a route to compact, portable traps for neutral molecules.

physics.atom-ph

Kinetic modeling of molecular beam formation in a cryogenic buffer-gas cell

Cryogenic buffer-gas cells are widely used to produce cold molecular beams, but the microscopic dynamics governing beam formation remain challenging to model. Here we present fully kinetic simulations of a cryogenic buffer-gas cell using the Direct Simulation Monte Carlo method implemented in the PICLas framework, treating the buffer gas and ablated molecules within a single unified model. We capture characteristic features of cryogenic buffer-gas sources, including plume cooling, directed transport toward the aperture, and the formation of a slow molecular beam, while also resolving energy transfer from the hot ablation plume to the helium buffer gas that is inaccessible to existing approaches relying on the background-gas approximation. Our results demonstrate that fully kinetic simulations can provide detailed insights into buffer-gas cell dynamics and open a route toward a systematic optimization of such sources.

physics.atom-ph