arXiv ScienceSearch

arXiv subjects

Axel Krieger

Publications and source records attributed to Axel Krieger.

At least 19 recordsLinked to original sources

SurgVIL: Scaling Surgical Robot Imitation Learning with Open-source Surgical Videos

Learning-based surgical robot autonomy requires large-scale demonstrations with synchronized videos and robot actions, but such data are exceedingly rare in clinical or realistic tissue settings because robot kinematics are typically inaccessible outside controlled research systems. In contrast, phantom data collected on research platforms provide accurate action labels but lack the visual diversity of real tissue. We propose SurgVIL, a framework for scaling surgical robot imitation learning using open-source surgical videos. SurgVIL combines kinematically labeled phantom robot demonstrations with surgical videos from open-source datasets and online sources for policy learning. Since these videos lack robot motion labels, we estimate approximate kinematics as weak supervision. We evaluate SurgVIL on two da Vinci robot tasks: needle pick-up and cholecystectomy cutting. Across ACT, $\pi_0$, and GR00T-H backbones, adding surgical videos substantially improves generalization to real-tissue and out-of-distribution settings, suggesting a scalable path from phantom training toward generalizable surgical robot policies.

cs.RO

AI-based single-shot structured-light depth reconstruction for real-time laparoscopic surgical guidance

Significance. Accurate intraoperative depth perception is important for autonomous and semi-autonomous robotic laparoscopic surgery. Conventional fringe projection profilometry can achieve millimeter-scale accuracy but often requires multi-shot acquisition, digital-micromirror-device projection, and projector-camera synchronization, complicating integration into compact laparoscopic systems. Aim. To develop a synchronization-free, single-shot depth-sensing platform using a passive LED-illuminated binary mask and a VQ-VAE prior with a custom U-Net depth head. Approach. A compact projection module was coupled to one channel of a dual-channel laparoscope, while the second channel imaged the fringe-illuminated target. A Zivid 3D camera acquired reference depth for 722 paired phantom images. Zivid depth maps were reprojected into the SSLE image frame for supervised training and evaluation. The VQ-VAE encoded each input into a discrete latent representation, and a latent-space U-Net predicted depth without a separate mask-prediction branch. Results. Using a fixed train/validation/test split, the proposed model achieved an MAE of 3.70 mm, AbsRel of 0.0326, delta=1.1 accuracy of 0.962, and delta=1.1^2 accuracy of 0.970. It achieved lower MAE than the dual U-Net MaskNet + DepthNet baseline and outperformed off-the-shelf monocular depth models in MAE, AbsRel, and threshold accuracy. The pipeline operated at 26.0 Hz over 301 consecutive frames on an NVIDIA A100 GPU. Conclusions. The LED-illuminated binary-pattern platform with latent-space depth reconstruction enables synchronization-free, video-rate endoscopic depth estimation. Results demonstrate Zivid-referenced phantom reconstruction without an explicit segmentation stage, while emphasizing the importance of dataset size and SSLE-Zivid calibration accuracy.

eess.IV

Robust Autonomous Control of a Magnetic Millirobot in In Vitro Cardiac Flow

Untethered magnetic millirobots offer significant potential for minimally invasive cardiac therapies; however, achieving reliable autonomous control in pulsatile cardiac flow remains challenging. This work presents a vision-guided control framework enabling precise autonomous navigation of a magnetic millirobot in an in vitro heart phantom under physiologically relevant flow conditions. The system integrates UNet-based localization, A* path planning, and a sliding mode controller with a disturbance observer (SMC-DOB) designed for multi-coil electromagnetic actuation. Although drag forces are estimated using steady-state CFD simulations, the controller compensates for transient pulsatile disturbances during closed-loop operation. In static fluid, the SMC-DOB achieved sub-millimeter accuracy (root-mean-square error, RMSE = 0.49 mm), outperforming PID and MPC baselines. Under moderate pulsatile flow (7 cm/s peak, 20 cP), it reduced RMSE by 37% and peak error by 2.4$\times$ compared to PID. It further maintained RMSE below 2 mm (0.27 body lengths) under elevated pulsatile flow (10 cm/s peak, 20 cP) and under low-viscosity conditions (4.3 cP, 7 cm/s peak), where baseline controllers exhibited unstable or failed tracking. These results demonstrate robust closed-loop magnetic control under time-varying cardiac flow disturbances and support the feasibility of autonomous millirobot navigation for targeted drug delivery.

cs.RO

Task-Space Singularity Avoidance for Control Affine Systems Using Control Barrier Functions

Singularities in robotic and dynamical systems arise when the mapping from control inputs to task-space motion loses rank, leading to an inability to determine inputs. This limits the system's ability to generate forces and torques in desired directions and prevents accurate trajectory tracking. This paper presents a control barrier function (CBF) framework for avoiding such singularities in control-affine systems. Singular configurations are identified through the eigenvalues of a state-dependent input-output mapping matrix, and barrier functions are constructed to maintain a safety margin from rank-deficient regions. Conditions for theoretical guarantees on safety are provided as a function of actuator dynamics. Simulations on a planar 2-link manipulator and a magnetically actuated needle demonstrate smooth trajectory tracking while avoiding singular configurations and reducing control input spikes by up to 100x compared to the nominal controller.

cs.RO

OA-NBV: Occlusion-Aware Next-Best-View Planning for Human-Centered Active Perception on Mobile Robots

We naturally step sideways or lean to see around the obstacle when our view is blocked, and recover a more informative observation. Enabling robots to make the same kind of viewpoint choice is critical for human-centered operations, including search, triage, and disaster response, where cluttered environments and partial visibility frequently degrade downstream perception. However, many Next-Best-View (NBV) methods primarily optimize generic exploration or long-horizon coverage, and do not explicitly target the immediate goal of obtaining a single usable observation of a partially occluded person under real motion constraints. We present Occlusion-Aware Next-Best-View Planning for Human-Centered Active Perception on Mobile Robots (OA-NBV), an occlusion-aware NBV pipeline that autonomously selects the next traversable viewpoint to obtain a more complete view of an occluded human. OA-NBV integrates perception and motion planning by scoring candidate viewpoints using a target-centric visibility model that accounts for occlusion, target scale, and target completeness, while restricting candidates to feasible robot poses. OA-NBV achieves over 90% success rate in both simulation and real-world trials, while baseline NBV methods degrade sharply under occlusion. Beyond success rate, OA-NBV improves observation quality: compared to the strongest baseline, it increases normalized target area by at least 81% and keypoint visibility by at least 58% across settings, making it a drop-in view-selection module for diverse human-centered downstream tasks.

cs.RO

AIMD-L: An automated laboratory for high-throughput characterization of structural materials for extreme environments

Rapid developments in artificial intelligence and machine learning as applied to materials science are creating an urgent need for experimental data, which can be provided by high-throughput and autonomous laboratories. To date most demonstrations of such laboratories have focused on functional materials, with less attention paid to structural materials. We present here the Artificial Intelligence in Materials Design Laboratory (AIMD-L), an automated, high-throughput facility for characterizing the microstructure and properties of structural metals and ceramics, with an emphasis on materials in extreme environments. AIMD-L has two custom instruments for characterization of structural materials: HELIX for shock studies of materials, and MAXIMA for X-ray diffraction and X-ray fluorescence spectroscopy. Specifically designed for high-throughput studies, HELIX and MAXIMA are each capable of collecting data at rates two to three orders of magnitude faster than conventional systems. A third experimental station, SPHINX, is a commercial nanoindenter modified for integration into the automated workflow of AIMD-L. A user (which may be human or an AI agent) directs the experiments to be carried out by means of a centralized control program. The experimental stations are linked by a conveyance that moves samples around the lab, with a robot at each station for sample transfer in/out of the instrument. The experimental stations also communicate with a common data layer that streams data autonomously from each instrument to a data portal, where their arrival triggers automated workflows for data reduction and analysis. The processed data are immediately available to the human operator or agentic AI, forming a closed loop for rapid decision-making and experimental control.

cond-mat.mtrl-sci

Modeling and Control of a Pneumatic Soft Robotic Catheter Using Neural Koopman Operators

Catheter-based interventions are widely used for the diagnosis and treatment of cardiac diseases. Recently, robotic catheters have attracted attention for their ability to improve precision and stability over conventional manual approaches. However, accurate modeling and control of soft robotic catheters remain challenging due to their complex, nonlinear behavior. The Koopman operator enables lifting the original system data into a linear "lifted space", offering a data-driven framework for predictive control; however, manually chosen basis functions in the lifted space often oversimplify system behaviors and degrade control performance. To address this, we propose a neural network-enhanced Koopman operator framework that jointly learns the lifted space representation and Koopman operator in an end-to-end manner. Moreover, motivated by the need to minimize radiation exposure during X-ray fluoroscopy in cardiac ablation, we investigate open-loop control strategies using neural Koopman operators to reliably reach target poses without continuous imaging feedback. The proposed method is validated in two experimental scenarios: interactive position control and a simulated cardiac ablation task using an atrium-like cavity. Our approach achieves average errors of 2.1 +- 0.4 mm in position and 4.9 +- 0.6 degrees in orientation, outperforming not only model-based baselines but also other Koopman variants in targeting accuracy and efficiency. These results highlight the potential of the proposed framework for advancing soft robotic catheter systems and improving catheter-based interventions.

cs.RO

Assessing Hemodynamic Impact of Tissue-Engineered Vascular Graft Displacement: Combining Postoperative in vivo Results and Computational Modeling to Improve Surgical Planning

Tissue-engineered vascular grafts (TEVG) have shown promise in advancing vascular reconstructions. However, precise in vivo implantation is challenging, and it is unclear how deviations in location and size affect hemodynamics. This study aims to compare preoperative designs and postoperative anatomies of TEVG in an in vivo study to evaluate discrepancies and investigate the impact of graft displacement and size on hemodynamics by virtually simulating implantation scenarios that are informed by in vivo postoperative results. Designed and postoperative geometries of four porcine aortas were compared to measure the mismatch in implantation location and graft shape. These results informed a virtual TEVG implantation study. TEVG location, orientation, and size were varied to investigate the effects on the final aorta shape and hemodynamics. Anastomosis of TEVG was simulated using finite element modeling. Key hemodynamic metrics were obtained from virtual implantations and actual postoperative anatomies using computational fluid dynamics. Our in vivo study showed that TEVGs can experience up to 6.9 mm displacement and a 38 degree rotational shift post-implantation, leading to discrepancies in pressure drop (2.5 mmHg, 50%) and time-averaged wall shear stress (7.2 Pa, 72%) compared to predictions. Virtual anastomosis simulations improved aortic shape predictions by 27.5%. Our results highlight the sensitivity of key hemodynamic metrics to graft implantation location and size mismatch. By quantifying displacement ranges and their impacts during surgery, surgeons can make informed decisions.

physics.med-ph

Fluoroscopy-Constrained Magnetic Robot Control via Zernike-Based Field Modeling and Nonlinear MPC

Magnetic actuation enables surgical robots to navigate complex anatomical pathways while reducing tissue trauma and improving surgical precision. However, clinical deployment is limited by the challenges of controlling such systems under fluoroscopic imaging, which provides low frame rate and noisy pose feedback. This paper presents a control framework that remains accurate and stable under such conditions by combining a nonlinear model predictive control (NMPC) framework that directly outputs coil currents, an analytically differentiable magnetic field model based on Zernike polynomials, and a Kalman filter to estimate the robot state. Experimental validation is conducted with two magnetic robots in a 3D-printed fluid workspace and a spine phantom replicating drug delivery in the epidural space. Results show the proposed control method remains highly accurate when feedback is downsampled to 3 Hz with added Gaussian noise (sigma = 2 mm), mimicking clinical fluoroscopy. In the spine phantom experiments, the proposed method successfully executed a drug delivery trajectory with a root mean square (RMS) position error of 1.18 mm while maintaining safe clearance from critical anatomical boundaries.

cs.RO

A Mobile Magnetic Manipulation Platform for Gastrointestinal Navigation with Deep Reinforcement Learning Control

Targeted drug delivery in the gastrointestinal (GI) tract using magnetic robots offers a promising alternative to systemic treatments. However, controlling these robots is a major challenge. Stationary magnetic systems have a limited workspace, while mobile systems (e.g., coils on a robotic arm) suffer from a "model-calibration bottleneck", requiring complex, pre-calibrated physical models that are time-consuming to create and computationally expensive. This paper presents a compact, low-cost mobile magnetic manipulation platform that overcomes this limitation using Deep Reinforcement Learning (DRL). Our system features a compact four-electromagnet array mounted on a UR5 collaborative robot. A Soft Actor-Critic (SAC)-based control strategy is trained through a sim-to-real pipeline, enabling effective policy deployment within 15 minutes and significantly reducing setup time. We validated the platform by controlling a 7-mm magnetic capsule along 2D trajectories. Our DRL-based controller achieved a root-mean-square error (RMSE) of 1.18~mm for a square path and 1.50~mm for a circular path. We also demonstrated successful tracking over a clinically relevant, 30 cm * 20 cm workspace. This work demonstrates a rapidly deployable, model-free control framework capable of precise magnetic manipulation in a large workspace,validated using a 2D GI phantom.

cs.RO

SurgiPose: Estimating Surgical Tool Kinematics from Monocular Video for Surgical Robot Learning

Imitation learning (IL) has shown immense promise in enabling autonomous dexterous manipulation, including learning surgical tasks. To fully unlock the potential of IL for surgery, access to clinical datasets is needed, which unfortunately lack the kinematic data required for current IL approaches. A promising source of large-scale surgical demonstrations is monocular surgical videos available online, making monocular pose estimation a crucial step toward enabling large-scale robot learning. Toward this end, we propose SurgiPose, a differentiable rendering based approach to estimate kinematic information from monocular surgical videos, eliminating the need for direct access to ground truth kinematics. Our method infers tool trajectories and joint angles by optimizing tool pose parameters to minimize the discrepancy between rendered and real images. To evaluate the effectiveness of our approach, we conduct experiments on two robotic surgical tasks: tissue lifting and needle pickup, using the da Vinci Research Kit Si (dVRK Si). We train imitation learning policies with both ground truth measured kinematics and estimated kinematics from video and compare their performance. Our results show that policies trained on estimated kinematics achieve comparable success rates to those trained on ground truth data, demonstrating the feasibility of using monocular video based kinematic estimation for surgical robot learning. By enabling kinematic estimation from monocular surgical videos, our work lays the foundation for large scale learning of autonomous surgical policies from online surgical data.

cs.RO

3D Path Planning for Robot-assisted Vertebroplasty from Arbitrary Bi-plane X-ray via Differentiable Rendering

Robotic systems are transforming image-guided interventions by enhancing accuracy and minimizing radiation exposure. A significant challenge in robotic assistance lies in surgical path planning, which often relies on the registration of intraoperative 2D images with preoperative 3D CT scans. This requirement can be burdensome and costly, particularly in procedures like vertebroplasty, where preoperative CT scans are not routinely performed. To address this issue, we introduce a differentiable rendering-based framework for 3D transpedicular path planning utilizing bi-planar 2D X-rays. Our method integrates differentiable rendering with a vertebral atlas generated through a Statistical Shape Model (SSM) and employs a learned similarity loss to refine the SSM shape and pose dynamically, independent of fixed imaging geometries. We evaluated our framework in two stages: first, through vertebral reconstruction from orthogonal X-rays for benchmarking, and second, via clinician-in-the-loop path planning using arbitrary-view X-rays. Our results indicate that our method outperformed a normalized cross-correlation baseline in reconstruction metrics (DICE: 0.75 vs. 0.65) and achieved comparable performance to the state-of-the-art model ReVerteR (DICE: 0.77), while maintaining generalization to arbitrary views. Success rates for bipedicular planning reached 82% with synthetic data and 75% with cadaver data, exceeding the 66% and 31% rates of a 2D-to-3D baseline, respectively. In conclusion, our framework facilitates versatile, CT-free 3D path planning for robot-assisted vertebroplasty, effectively accommodating real-world imaging diversity without the need for preoperative CT scans.

cs.RO

A Supervised Autonomous Resection and Retraction Framework for Transurethral Enucleation of the Prostatic Median Lobe

Concentric tube robots (CTRs) offer dexterous motion at millimeter scales, enabling minimally invasive procedures through natural orifices. This work presents a coordinated model-based resection planner and learning-based retraction network that work together to enable semi-autonomous tissue resection using a dual-arm transurethral concentric tube robot (the Virtuoso). The resection planner operates directly on segmented CT volumes of prostate phantoms, automatically generating tool trajectories for a three-phase median lobe resection workflow: left/median trough resection, right/median trough resection, and median blunt dissection. The retraction network, PushCVAE, trained on surgeon demonstrations, generates retractions according to the procedural phase. The procedure is executed under Level-3 (supervised) autonomy on a prostate phantom composed of hydrogel materials that replicate the mechanical and cutting properties of tissue. As a feasibility study, we demonstrate that our combined autonomous system achieves a 97.1% resection of the targeted volume of the median lobe. Our study establishes a foundation for image-guided autonomy in transurethral robotic surgery and represents a first step toward fully automated minimally-invasive prostate enucleation.

cs.RO

Current validation practice undermines surgical AI development

Surgical data science (SDS) is rapidly advancing, yet clinical adoption of artificial intelligence (AI) in surgery remains limited, with inadequate validation as an important contributing factor. Existing validation practices often neglect the temporal and hierarchical structure of intraoperative videos, yielding misleading or clinically irrelevant results. We introduce a comprehensive catalogue of validation pitfalls in AI-based surgical video analysis, derived from a multi-stage Delphi process with 92 international experts. Pitfalls span three categories: (1) data, (2) metric selection/configuration, and (3) aggregation and reporting. A systematic review of surgical AI papers reveals that these pitfalls are widespread. Experiments on surgical video datasets show that ignoring temporal and hierarchical data structures can understate uncertainty, obscure critical failure modes, and alter algorithm rankings. To address these shortcomings, we provide consensus-based best practices compiled. Together, this work provides an evidence-based framework for rigorous validation of surgical video analysis algorithms, guiding benchmarking, reporting, regulatory review, and clinical translation.

q-bio.OT

Investigating Robot Control Policy Learning for Autonomous X-ray-guided Spine Procedures

Imitation learning-based robot control policies are enjoying renewed interest in video-based robotics. However, it remains unclear whether this approach applies to X-ray-guided procedures, such as spine instrumentation, with sparse inputs. We examine the feasibility, opportunities and challenges for imitation policy learning in bi-plane-guided cannula insertion. We develop an in silico sandbox for scalable, automated simulation of X-ray-guided spine procedures with a high degree of realism. We curate a dataset of correct trajectories and corresponding bi-planar X-ray sequences that emulate the stepwise alignment of providers. We then train imitation learning policies for planning and open-loop control that iteratively align a cannula in a vertebroplasty setting solely based on visual information. This precisely controlled setup offers insights into limitations and capabilities of this method. Our policy succeeded on the first attempt in 68.5% of cases, maintaining safe intra-pedicular trajectories across diverse vertebral levels. The policy transferred to complex anatomy, including fractures, as well as varied anatomies and initializations. Rollouts on real X-ray indicate that partial sim-to-real transfer with plausible trajectories is possible. While these preliminary results are promising, we also identify limitations, especially in entry point precision. The current results present a clear benchmark for future efforts, while with more robust priors and domain knowledge, such models may provide a foundation for future efforts toward lightweight and CT-free robotic intra-operative spinal navigation.

cs.CV

SutureBot: A Precision Framework & Benchmark For Autonomous End-to-End Suturing

Robotic suturing is a prototypical long-horizon dexterous manipulation task, requiring coordinated needle grasping, precise tissue penetration, and secure knot tying. Despite numerous efforts toward end-to-end autonomy, a fully autonomous suturing pipeline has yet to be demonstrated on physical hardware. We introduce SutureBot: an autonomous suturing benchmark on the da Vinci Research Kit (dVRK), spanning needle pickup, tissue insertion, and knot tying. To ensure repeatability, we release a high-fidelity dataset comprising 1,890 suturing demonstrations. Furthermore, we propose a goal-conditioned framework that explicitly optimizes insertion-point precision, improving targeting accuracy by 59\%-74\% over a task-only baseline. To establish this task as a benchmark for dexterous imitation learning, we evaluate state-of-the-art vision-language-action (VLA) models, including $\pi_0$, GR00T N1, OpenVLA-OFT, and multitask ACT, each augmented with a high-level task-prediction policy. Autonomous suturing is a key milestone toward achieving robotic autonomy in surgery. These contributions support reproducible evaluation and development of precision-focused, long-horizon dexterous manipulation policies necessary for end-to-end suturing. Dataset is available at: https://huggingface.co/datasets/jchen396/suturebot

cs.RO

Cosmos-Surg-dVRK: World Foundation Model-based Automated Online Evaluation of Surgical Robot Policy Learning

The rise of surgical robots and vision-language-action models has accelerated the development of autonomous surgical policies and efficient assessment strategies. However, evaluating these policies directly on physical robotic platforms such as the da Vinci Research Kit (dVRK) remains hindered by high costs, time demands, reproducibility challenges, and variability in execution. World foundation models (WFM) for physical AI offer a transformative approach to simulate complex real-world surgical tasks, such as soft tissue deformation, with high fidelity. This work introduces Cosmos-Surg-dVRK, a surgical finetune of the Cosmos WFM, which, together with a trained video classifier, enables fully automated online evaluation and benchmarking of surgical policies. We evaluate Cosmos-Surg-dVRK using two distinct surgical datasets. On tabletop suture pad tasks, the automated pipeline achieves strong correlation between online rollouts in Cosmos-Surg-dVRK and policy outcomes on the real dVRK Si platform, as well as good agreement between human labelers and the V-JEPA 2-derived video classifier. Additionally, preliminary experiments with ex-vivo porcine cholecystectomy tasks in Cosmos-Surg-dVRK demonstrate promising alignment with real-world evaluations, highlighting the platform's potential for more complex surgical procedures.

cs.RO

Toward Autonomous Soft Robotic Endovascular Navigation via Imitation Learning

In endovascular surgery, endovascular interventionists push a thin tube called a catheter, guided by a thin wire to a treatment site inside the patient's blood vessels to treat various conditions such as blood clots, aneurysms, and malformations. Robotic guidewires can enhance maneuverability but are difficult to model and control. Autonomous soft robotic guidewire navigation has the potential to overcome these challenges, increasing the precision and safety of endovascular navigation. As a first step, we establish a large-scale, 2D-projected environment for autonomous navigation. In other surgical domains, end-to-end imitation learning has shown promising results. Thus, we develop a transformer-based imitation learning framework with goal conditioning, relative action outputs, and automatic contrast dye injections to enable generalizable soft robot navigation in an aneurysm targeting task. We train the policy on 36 different modular bifurcated geometries, generating 647 total demonstrations under simulated fluoroscopy, and evaluate it on three previously unseen vascular geometries. The policy reaches the aneurysm with a success rate of 83% on the unseen geometries, outperforming several baselines. In addition, ablation and baseline studies evaluate the effectiveness of each design and data collection choice. Lastly, we extend the policy to achieve 75% success on an unseen patient-derived geometry. Project website: https://softrobotnavigation.github.io/

cs.RO