arXiv · 2611.23619
EEG2MCU: Sensing-to-Execution Co-Design for Wearable EEG Inference
Abstract
Wearable EEG inference is constrained not only by model size, but also by the channel-dependent sensing front end that must process high-dimensional inputs before compact downstream computation. We present EEG2MCU, a sensing-to-execution co-design framework that treats electrode count as a hardware design variable through task-aware montage selection. EEG2MCU retains a compact time-frequency representation and generates only the INT8 regions required by each first-layer tile, avoiding full input materialization. Halo reuse and access-aware placement across Flash, SRAM, and tightly coupled memory further reduce redundant generation and data movement. On a Cortex-M7 MCU, EEG2MCU reduces peak SRAM by 11.38x relative to the baseline, including a 1.71x reduction from the 62-to-19 electrode montage, while reducing latency by 2.57x and energy by 2.48x. It retains 94-96% of full-montage accuracy, demonstrating practical high-dimensional EEG inference under tight embedded-resource constraints.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Shoma Yukawa, Meghna Roychowdhury, Arnab Sanyal, Chengwei Zhou, Shreyas Sen, Gourav Datta. 2026-11-17. EEG2MCU: Sensing-to-Execution Co-Design for Wearable EEG Inference. https://arxiv.science/abs/2611.23619
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.