Evaluation of Performance of the p-stop fabrication process variations in ATLAS18 strip sensors, Pre- and Post-Irradiation

Abstract

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). Radiation-hard n-in-p micro-strip sensors were developed for use in the ITk. During quality control (QC) and quality assurance (QA) procedures performed on ATLAS18 production sensors and test chips, ATLAS ITk strip sensor institutes identified instances of low p-stop density in certain production batches. To investigate the origin of these issues and to try some technological improvements, two dedicated sample batches with four variations of the p-stop fabrication process were produced. These process types (1-4) were systematically evaluated to determine their effectiveness and uniformity. In total, 56 full-size sensors, along with numerous miniature sensors and test chips, were tested. A number of samples were used in the irradiation campaign reaching the maximum expected levels for the HL-LHC operation after 10 years - with neutrons up to 1.6E15 neq/cm2, and with gamma rays from a 60Co source up to 66 Mrad. The goal of this evaluation program is to assess the impact of of p-stop fabrication process variations on interstrip isolation performance and to provide feedback for future sensor development. This paper describes the applied test procedures and presents the corresponding results, which demonstrate good sensor performance for all investigated p-stop types. The findings confirm the reliability of the evaluated designs and identify specific advantages that can inform further optimization of strip sensor fabrication.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J. Kozakova, A. Affolder, K. Affolder, A. Awais, E. Bach, G. A. Beck, P. Bernabeu, A. J. Bevan, Z. Chen, V. Cindro, B. Crick, J. Dandoy, I. Dawson, V. Fadeyev, P. Federicova, C. Fleta, P. Gallus, C. Jessiman, S. Katznelson, J. Keller, C. T. Klein, T. Koffas, J. Kroll, M. Kutova, J. Kvasnicka, C. Lacasta, I. Mandic, R. R. Marcelo Gregorio, F. Martinez-McKinney, M. Mikestikova, P. S. Miyagawa, L. Morelos-Zaragoza, R. S. Orr, Q. Paddock, C. Solaz, U. Soldevila, E. Staats, P. Tuma, M. Ullan, Y. Unno, M. Vansteenkiste, P. Wishart, S. C. Zenz, Y. Zhao. 2026-11-16. Evaluation of Performance of the p-stop fabrication process variations in ATLAS18 strip sensors, Pre- and Post-Irradiation. https://doi.org/10.1016/j.nima.2026.171783. https://arxiv.science/abs/2611.21101

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite arXiv Science by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Improved Pion-Kaon Identification in Heavy-Ion Collisions with a Two-Dimensional Transformation

Accurate identification of charged pions and kaons is essential for precision measurements in relativistic heavy-ion collisions, but becomes increasingly challenging at intermediate and high transverse momentum because of the increasing overlap of the TPC and TOF particle identification responses. In this work, we quantitatively benchmark a two-dimensional shift-and-rotation PID procedure that combines the $nσ_π$ and mass-squared $(m^{2})$ information. The benchmark is performed using Au+Au collision events generated with the AMPT model, where the detector response is modeled using $p_{T}$-dependent PID parameters extracted from STAR data. Since the true particle identities and input yields are known in AMPT but are not used during the reconstruction, the procedure can be evaluated through a direct closure test that is not possible with experimental data alone. The two-dimensional procedure is compared with a reference one-dimensional method consisting of an $|nσ_π|<$ 3 preselection followed by a Gaussian fit to the $m^{2}$ distribution. While both methods perform well when pion and kaon PID responses are well separated, the two-dimensional procedure provides improved yield closure as the PID distributions increasingly overlap at high $p_{T}$. The reconstructed-to-input yield ratio remains within 2\% of unity up to $p_T =$ 3 GeV/$c$, whereas the reference one-dimensional procedure shows a larger deviation. Reaction-plane $v_{2}$ closure tests show that both the reference one-dimensional and two-dimensional PID procedures reproduce the AMPT input $v_{2}$ within the statistical uncertainties over the studied $p_{T}$ range. These results demonstrate that the two-dimensional procedure substantially improves the high-$p_{T}$ yield reconstruction without introducing a detectable bias in the extracted $v_{2}$ under the STAR-like detector response considered here.

physics.ins-det↗

Cryogenic Mechanical Loss of GaAs/AlGaAs Crystalline Coatings

Optical coatings with minimal thermal noise are essential for high-precision, laser-based metrology experiments. Substrate-transferred crystalline GaAs/Al$_{0.92}$Ga$_{0.08}$As coatings have the lowest thermal noise for high-reflectivity mirror coatings with $λ=900$ nm -- 12 $μ$m. Time-frequency stabilization experiments have demonstrated that GaAs/AlGaAs mirror coatings have a lower noise floor than amorphous mirror coatings. These mirrors are now being developed at sizes $\ge 300$ mm for gravitational-wave detectors. In order to understand the coating's fundamental loss mechanisms, which cause thermal noise, we have performed the first measurement of the mechanical loss at cryogenic temperatures using a cryogenic, multimodal, gentle nodal suspension system, which operates from 12 K to room temperature. This initial measurement used a silicon substrate whose asymmetry produced excess friction with the nodal support. Accounting for this friction and Akhiezer loss in the substrate and coating, the mechanical loss agrees well with the thermal noise observed in experiments using cryogenic fixed-cavities with GaAs/AlGaAs mirrors.

physics.ins-det↗

Rotating Capacitive System for Measurement of a Third Order Gravity Gradient Based on a Single-Axis Mechanical Oscillator. Part I, Theory

This paper is a feasibility study on a single-axis mechanical oscillator, mounted on a miniature circular rotating platform, that is proposed to be used for measuring a quantity proportional to the second vertical derivative of gravitational acceleration projected onto the oscillator's sensitivity axis. The latter is aligned with the axis of rotation. Part I establishes theoretical feasibility only. Design constraints, quantitative sensitivity, error budgets, and mobile platform performance will be addressed in Part II.

physics.ins-det↗