arXiv ScienceSearch

arXiv · 2609.19658

Proposing, never assigning: fair allocation of control-room shifts in experimental particle physics collaborations from ranked wishes under institutional quotas

Abstract

Experimental particle physics collaborations staff their detectors around the clock with members drawn from dozens of institutions. The established practice is a credit system with self-sign-up: institutions owe a quota of credit, and people take the seats they want when booking opens. This paper describes a method in which seats are instead allocated from ranked wishes under institutional quotas, the result is issued as offers that each person accepts or declines, and an independent checker recomputes every rule before anything is published: the platform proposes, never assigns, and proves that it kept the rules. The credit and quota model is inherited from current practice. Around that core the paper adds a quota rule that keeps indivisible blocks fair to institutions whose share of a period is smaller than one block, and four rules that make fairness visible beyond the count: shares of owl, weekend and holiday blocks, seats shown in the laboratory's clock and the institution's own, reachable pools for institutions that cannot travel, and booking order by balance. On a synthetic collaboration of 48 institutions and 256 eligible members, the method allocates 70 to 72 of 72 seats per period in two rounds, with a mean rank satisfaction of 84 to 95% and no rule broken; after a year of running every institution of four members or more is within 13% of its cumulative share, and the smallest institutions, which one block overshoots by arithmetic, are brought within the same range by pooling in pairs. The method is stated completely enough to be reimplemented; a reference implementation exists and is available to collaborations under license. It applies as it stands to any scientific collaboration that staffs a facility in blocks of shifts under institutional quotas.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kamal Benslama. 2026-09-17. Proposing, never assigning: fair allocation of control-room shifts in experimental particle physics collaborations from ranked wishes under institutional quotas. https://arxiv.org/abs/2609.19658

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det