arXiv ScienceSearch

arXiv · 2606.20719

Scene-based field validation of wearable light loggers

Abstract

Wearable light loggers are increasingly used to measure personal light exposure. However, there is no standardised method to test how well these devices perform in real-world settings. To address this, we developed a scene-based field validation framework combining wearable light loggers, laboratory-grade spectral reference instruments, and image-based scene characterisation to evaluate wearable performance in the field. We applied the validation framework to ActTrust2 and ActLumus light loggers using 433 natural, everyday scenes across two sites: Tübingen, Germany (n=210), and Izmir, Türkiye (n=223), spanning indoor and outdoor environments in daylight, artificial light and mixed scenarios, across wide range of photopic and melanopic equivalent daylight illuminances. Both light loggers exhibited high agreement with the reference instruments (R^2=0.988-0.990), but they systematically underestimated light exposure. The lighting condition, scene complexity, time of day, and study site contributed significantly to measurement bias. Resampling under specific lighting conditions indicated that bias ranged from -0.065 log units in daylight-only situations to -0.195 log units in artificial-only situations. This suggested that single-condition assessments with limited spectra or scene categories can underestimate or overestimate overall wearable performance. Bootstrap resampling demonstrated that performance estimates stabilised at approximately 100 scenes, indicating that a diverse sample of this size is sufficient for reliable field validation. Finally, cross-site validation showed consistent performance across two sites, supporting the framework's reproducibility. Overall, these findings establish our validation framework as an effective tool for guiding scene diversity and sampling design for ecologically valid field validation of wearable light loggers.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Burcu Gemici, Niloufar Tabandeh, Cansu Ozkucukler, Johannes Zauner, Altug Didikoglu, Manuel Spitschan. 2026-06-16. Scene-based field validation of wearable light loggers. https://arxiv.org/abs/2606.20719

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det