Understanding Energy Flow and Inefficiency of a Thermomagnetic Generator by Transient Multi-Physics Modelling

Abstract

Waste heat recovery improves energy efficiency and reduces greenhouse gas emissions; however, much industrial and environmental heat is wasted at low temperature. Thermomagnetic recovery of waste heat has a high potential for sustainable production of electric energy, especially for low-grade waste heat where conventional technology is inefficient or infeasible. Of particular interest are thermomagnetic generators (TMG) as they require almost no mechanically moving parts, which is beneficial for high reliability. However, all existing prototypes have two remaining challenges: low efficiency and low cycle frequency. In this work, we develop a digital twin of a recent TMG with genus 3 by using multi-physics simulations. We identify shortcomings of previous simulation approaches, and describe why simulations in three dimensions are necessary, which consider coupling between magnetic, thermal, fluid flow, and electrical physics domains. We validate our model, which only uses known geometry and material parameters, by experimental data of the TMG with highest power density today, and attain 96% accuracy in open-circuit voltage and 95% accuracy in power output. This high accuracy allows us to identify the origin of both challenges for TMGs, which are not accessible by experiments. First, we uncover inefficiencies by analyzing the energy flow within a Sankey diagram. Second, we trace the transient heat flow through the generator, which identifies the factors limiting frequency. This paves the way for more efficient and faster TMGs, and their development will be accelerated by our validated digital twin.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ali Izadi, Bruno Neumann, Sebastian Fähler. 2026-04-18. Understanding Energy Flow and Inefficiency of a Thermomagnetic Generator by Transient Multi-Physics Modelling. https://arxiv.org/abs/2605.00017

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Identifiability of the three-dimensional anisotropic thermal-conductivity tensor in thermoreflectance measurements: Single-orientation limits and full-tensor recover

Materials with full anisotropic thermal conductivity tensors are widely used in advanced applications, creating a need for dedicated characterization. Such tensors contain six independent components: three diagonal conductivities and three non-zero off-diagonal couplings. However, whether thermoreflectance measurements on a single crystalline orientation can uniquely determine an arbitrary tensor remains unclear. Here, we show that every fully anisotropic thermal-conductivity tensor admits a Schur-equivalent tensor with zero cross-plane couplings ($k_{xz}=k_{yz}=0$). The two tensors produce identical surface thermal responses, and this equivalence persists as frequency, delay time, beam geometry, and spatial offset vary. We further demonstrate that parameter-identifiability assessments based on heuristic interpretations of sensitivity trends or singular-value decomposition (SVD) of the sensitivity matrix cannot, by themselves, rule out globally equivalent solutions in fully anisotropic systems. Combining systematic analysis with numerical validation, we provide guidance on selecting signals and measurement orientations for full-tensor characterization. Specifically, measurements at three mutually orthogonal crystallographic orientations provide complementary information for full-tensor recovery. These findings clarify the limits of single-surface measurements and establish a systematic approach to characterizing fully anisotropic thermal-conductivity tensors.

physics.app-ph

RCS angular control with gradient metasurfaces: design and measurement

This letter proposes the design and measurement of a periodic metasurface that achieves anomalous reflection with reduced RCS in a given parasitic direction. A previous study proposed a semi-analytical model to predict the RCS behavior of such a metasurface. However, this first study did not include any experimental exploration to verify the theoretical results. To complete this study, this work presents an experimental validation of the proposed design, with a focus on manufacturing and measurement issues. The synthesis, design specifications, fabrication method and experimental setup are presented and discussed. Measurement results are also examined in detail, highlighting some limitations in metasurfaces RCS measurements. The proposed metasurface effectively achieves the predicted RCS level reduction in the considered parasitic direction. The agreement between simulation and experimental results demonstrates the accuracy of the modelling and the efficiency of the optimisation procedure.

physics.app-ph

Maximum-Power-Transfer Power Coordinates for Fully Coupled Multiport Thévenin Sources

A power-normalized scattering representation is developed at a fixed frequency for a passive linear time-invariant multiport load driven by a fully coupled multiport Thévenin source. The source is obtained by reducing, at the load reference planes, an independent-source network whose suppressed internal impedance is passive, together with an intervening passive matching network. No diagonal-reference, uncoupled-source-channel, reciprocity, or commutation assumption is required. With $R_s=\mathrm{Herm}\{Z_s\}\succ\mathbf{0}$, completing the square in accepted power identifies the available-power current and motivates the coordinates $\mathbf{a}=\frac12R_s^{-1/2}(\mathbf{V}+Z_s\mathbf{I})$, $\mathbf{b}=\frac12R_s^{-1/2}(\mathbf{V}-Z_s^H\mathbf{I})$. They satisfy $\|\mathbf{a}\|_2^2-\|\mathbf{b}\|_2^2=\Re\{\mathbf{I}^H\mathbf{V}\}$ and yield $\mathbf{S}=R_s^{-1/2}(Z_{load}-Z_s^H)(Z_{load}+Z_s)^{-1}R_s^{1/2}$. An exact operator identity establishes passivity--contractivity equivalence and gives excitation-specific, reachable-subspace, and complete conjugate-matching conditions. On the physically reachable incident subspace, singular values characterize the best- and worst-case source-normalized port-reflection TARC, while a restricted Frobenius norm gives the basis-averaged squared TARC. Equal-magnitude phase-only control is formulated separately as a constant-modulus problem, with generator-side constraints mapped through the coupled source network before power normalization. For antenna loads and excitations with $P_{acc}>0$, $P_{rad}/P_{av}=η_{rad}(1-\mathrm{TARC}^2)$, so terminal scattering data alone do not determine radiation efficiency. When $R_s$ is singular, finite available power exists exactly for $\mathbf{E}\in\mathrm{range}(R_s)$, and the construction applies on the positive-resistance support.

physics.app-ph