arXiv ScienceSearch

arXiv · 2602.16828

Performance of the Endcap Time-of-Flight detector in the STAR beam-energy scan

Abstract

The STAR experiment at RHIC at Brookhaven National Laboratory completed the installation of an endcap time-of-flight subsystem (eTOF) in February 2019. The eTOF subsystem provided essential mid-rapidity particle identification (PID) for the fixed-target (FXT) portion of phase II of the beam energy scan (BES II). The FXT program allowed BES II to include center-of-mass energies from $\sqrt{s_{_{NN}}} = 3.0$ GeV to $\sqrt{s_{_{NN}}} = 7.7$ GeV, not accessible by colliding beams. The eTOF detectors and readout electronics were designed for the CBM experiment at FAIR and adapted for use at STAR. In this paper, we describe the details of the system in terms of geometrical layout, acceptance, calibration, hit reconstruction, and particle identification. The system achieved a time resolution of about 70 ps and a PID efficiency of about 70\%, meeting the design goals of the project.

Explore related subjects

Keep this discovery

BibTeXRIS

Mathias C. Labonté, Daniel Cebra, Zachary Sweger, Geary Eppley, Frank Geurts, Yannick Söhngen, Norbert Herrmann, Esteban Rubio, Philipp Weidenkaff, Ingo Deppner, Pierre-Alain Loizeau, Jochen Frühauf, David Emschermann, Florian Seck, David Tlusty, Dongdong Hu, Yongjie Sun, Tonko Ljubicic, Yi Wang. 2026-02-18. Performance of the Endcap Time-of-Flight detector in the STAR beam-energy scan. https://doi.org/10.1016/j.nima.2026.171612

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det