arXiv ScienceSearch

arXiv · 2408.14071

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

Abstract

DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ~100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout the experiment's lifetime of over 10 years. Continuous removal of impurities and radon from the UAr is essential for maximising signal yield and mitigating background. We are developing an efficient and powerful cryogenics system with a gas purification loop with a target circulation rate of 1000 slpm. Central to its design is a condenser operated with liquid nitrogen which is paired with a gas heat exchanger cascade, delivering a combined cooling power of more than 8 kW. Here we present the design choices in view of the DS-20k requirements, in particular the condenser's working principle and the cooling control, and we show test results obtained with a dedicated benchmarking platform at CERN and LNGS. We find that the thermal efficiency of the recirculation loop, defined in terms of nitrogen consumption per argon flow rate, is 95 % and the pressure in the test cryostat can be maintained within $\pm$(0.1-0.2) mbar. We further detail a 5-day cool-down procedure of the test cryostat, maintaining a cooling rate typically within -2 K/h, as required for the DS-20k inner detector. Additionally, we assess the circuit's flow resistance, and the heat transfer capabilities of two heat exchanger geometries for argon phase change, used to provide gas for recirculation. We conclude by discussing how our findings influence the finalisation of the system design, including necessary modifications to meet requirements and ongoing testing activities.

Explore related subjects

Keep this discovery

BibTeXRIS

20k Collaboration, F. Acerbi, P. Adhikari, P. Agnes, I. Ahmad, S. Albergo, I. F. M. Albuquerque, T. Alexander, A. K. Alton, P. Amaudruz, M. Angiolilli, E. Aprile, R. Ardito, M. Atzori Corona, D. J. Auty, M. Ave, I. C. Avetisov, O. Azzolini, H. O. Back, Z. Balmforth, A. Barrado Olmedo, P. Barrillon, G. Batignani, P. Bhowmick, S. Blua, V. Bocci, W. Bonivento, B. Bottino, M. G. Boulay, A. Buchowicz, S. Bussino, J. Busto, M. Cadeddu, M. Cadoni, R. Calabrese, V. Camillo, A. Caminata, N. Canci, A. Capra, M. Caravati, M. Cárdenas-Montes, N. Cargioli, M. Carlini, A. Castellani, P. Castello, P. Cavalcante, S. Cebrian, J. Cela Ruiz, S. Chashin, A. Chepurnov, L. Cifarelli, D. Cintas, M. Citterio, B. Cleveland, Y. Coadou, V. Cocco, D. Colaiuda, E. Conde Vilda, L. Consiglio, B. S. Costa, M. Czubak, M. D'Aniello, S. D'Auria, M. D. Da Rocha Rolo, G. Darbo, S. Davini, S. De Cecco, G. De Guido, G. Dellacasa, A. V. Derbin, A. Devoto, F. Di Capua, A. Di Ludovico, L. Di Noto, P. Di Stefano, L. K. Dias, D. Díaz Mairena, X. Ding, C. Dionisi, G. Dolganov, F. Dordei, V. Dronik, A. Elersich, E. Ellingwood, T. Erjavec, M. Fernandez Diaz, A. Ficorella, G. Fiorillo, P. Franchini, D. Franco, H. Frandini Gatti, E. Frolov, F. Gabriele, D. Gahan, C. Galbiati, G. Galiński, G. Gallina, G. Gallus, M. Garbini, P. Garcia Abia. 2024-08-26. Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k. https://doi.org/10.1088/1748-0221%2F20%2F02%2Fp02016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det