arXiv ScienceSearch

arXiv · 2402.01517

First test beam measurement of the 4D resolution of an RSD 450 microns pitch pixel matrix connected to a FAST2 ASIC

Abstract

This paper reports on the spatial and temporal resolutions of an RSD 450 microns pitch pixels array measured at the DESY test beam facility. RSDs, Resistive Silicon Detectors, also known as AC-LGAD, achieve excellent position and temporal resolution by exploiting charge sharing among neighboring electrodes. The RSD matrix used in this study is part of the second FBK RSD production, RSD2, and it is composed of 450 microns pitch pixel with cross-shaped electrodes. A 7-pixel matrix was read out by the FAST2 ASIC, a 16-channel amplifier fully custom ASIC developed by INFN Torino using the 110 nm CMOS technology. The total area covered by the matrix is about 1.5 mm$^2$. The position resolution reached in this test is 15 microns, about 4\% of the pitch. The temporal resolution achieved in this work is 60 ps, dominated by the FAST2 resolution. The work also demonstrates that RSD sensors with cross-shaped electrodes achieve 100% fill factor and homogenous resolutions over the whole matrix surface, making them a suitable choice for 4D tracking applications.

Explore related subjects

Keep this discovery

BibTeXRIS

L. Menzio, F. Siviero, R. Arcidiacono, N. Cartiglia, M. Costa, T. Croci, M. Ferrero, C. Hanna, L. Lanteri, S. Mazza, R. Mulargiaa, H-F W. Sadrozinski, A. Seiden, V. Sola, R. Whitea, M. Wilder. 2024-02-02. First test beam measurement of the 4D resolution of an RSD 450 microns pitch pixel matrix connected to a FAST2 ASIC. https://arxiv.org/abs/2402.01517

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det