arXiv · 2104.02579
The Automatic Calibration Unit in JUNO
Abstract
This paper describes the design and construction of the automatic calibration unit (ACU) for the JUNO experiment. The ACU is a fully automated mechanical system. It is capable of deploying multiple radioactive sources, an ultraviolet (UV) laser source, or an auxiliary sensor such as a temperature sensor, one at a time, into the central detector of JUNO along the central axis. It is designed as a primary tool to precisely calibrate the energy scale of detector, aligning timing for the photosensors, and partially monitoring the position-dependent energy scale variations.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Jiaqi Hui, Hancheng Liu, Jianglai Liu, Yue Meng, Mengjiao Xiao, Donglian Xu, Lei Yang, Ziping Ye, Feiyang Zhang, Tao Zhang, Yuanyuan Zhang. 2021-06-26. The Automatic Calibration Unit in JUNO. https://doi.org/10.1088/1748-0221%2F16%2F08%2Ft08008