arXiv ScienceSearch

arXiv · 2011.10394

Intrinsic Spatial Resolution Limit in Analyzer-Based X-Ray Phase Contrast Imaging Technique

Abstract

Dynamical diffraction effects always play a role when working with perfect single crystals. The penetration of X-rays respect to the surface normal during diffraction (extinction depth, $1/σ_e$) in perfect single crystals does not have a constant value. The value changes for different angular positions on the crystal diffraction condition. For higher X-ray energies this value can change from few micrometers to tens of millimeters for each different crystal angular position in the small angular range of the diffraction condition. This effect may spread a single point in the object (sample) as a line in the image detector, especially if the crystal is set (or if the sample angularly deviates the beam) at lower diffraction angle positions, where the surface component of X-ray penetration can achieve huge values. Then, for imaging experiments where the dynamical diffraction occurs, such intrinsic property can affect the image resolution. We have modeled and experimentally checked such a dynamical diffraction property using, as example, an Analyzer-based X-ray phase contrast imaging setup (ABI) at two different X-ray energies: 10.7 keV and 18 keV. The results show that our theoretical model is consistent with the measured results. For higher energies the blur effect is enhanced and intrinsically limits the image spatial resolution.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Marcelo G. Honnicke, Sergio L. Morelhao. 2021-01-08. Intrinsic Spatial Resolution Limit in Analyzer-Based X-Ray Phase Contrast Imaging Technique. https://doi.org/10.1016/j.radphyschem.2019.04.023

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Development of an Extensible Unified Control System Using the STARS Framework and Common Commands for Detector Control

A zooming optical system comprising two Fresnel zone plates (FZPs) was developed and installed at the AR-NE1A beamline of the Photon Factory, High Energy Accelerator Research Organization (KEK), Japan. To ensure reliable and versatile operation, we implemented a dedicated control architecture based on the Simple Transmission and Retrieval System (STARS) framework and the newly proposed STARS Common Commands for Detector Control (CCDC)---a data-acquisition (DAQ) state model and command set designed specifically for detector control. The system serves both as a practical control system for the zooming optics and as a demonstration of modular extensibility using STARS and detector interoperability through CCDC. The system has been commissioned, and its performance has been verified at the AR-NE1A beamline. The architecture enables flexible configuration of optical components and provides a unified interface for both routine operation and advanced experimental protocols.

physics.ins-det

Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors

Experimental TCAD calibration is essential for predictive technology modeling of emerging oxide semiconductor transistors. However, it remains time-consuming and expert dependent because of model ambiguity. Multiple physical models and parameter sets can reproduce the same measured transfer characteristics, while local fitting alone cannot uniquely identify the underlying device physics. We present the first demonstration of an agentic TCAD calibration workflow for a fabricated bottom-gate In--W--O (BG-IWO) transistor. Starting from the measured transfer curve and device information, the workflow uses measurement--TCAD residuals and local sensitivity tests to select bounded parameter corrections or evaluate additional physical models, and accept only updates that improve device metrics. The LLM agent orchestrates the workflow, while Sentaurus governs the device physics. For the 2\%-W reference device, five agent-suggested updates yield a fixed calibrated model, reducing the multi-metric device objective $J$ by 14.3$\times$. Maximum $V_{\mathrm{th}}$/$I_{\mathrm{on}}$ errors are 36.1~mV/0.022 decade for varying-drain-bias tests and 46.2~mV/0.062 decade for varying-channel-length tests, demonstrating model transferability across bias and geometry rather than a local parameter fit. W-composition tests provide process-sensitive insight. This agentic workflow provides a faster route to model development for emerging device technologies.

physics.ins-det

Birefringence of AlGaAs/GaAs Coatings under Above-Band-Gap Illumination, GR Noise and Photo-Optic Transfer Function

AlGaAs/GaAs coatings are being considered as coating candidates for gravitational-wave detectors. In this paper we investigate the birefringence properties of this crystalline semiconductor material by modulating the optical illumination on the mirror coating and monitoring the induced birefringence. While the measured low-frequency birefringence values align with previous studies, we observed a frequency-dependent behavior in the illumination-to-birefringence coupling, characterized by a pole increasing with illumination intensity and a gain at zero frequency (DC gain) decreasing with illumination intensity. We developed a generic theoretical model based on a master equation to characterize the measurement results by considering photon-induced electric fields and electro-optic effects. This model can fit the frequency and intensity dependencies of the induced birefringence. Additionally, this model predicts a generation-recombination noise (GR noise) will be observable in the coating birefringence. While the presented measurement cannot predict the exact level of GR noise, for the frequency band and spot sizes relevant for gravitational-wave detectors we expect GR noise to be white below the pole frequency, scale with power the same way laser shot noise does, and for fixed power be independent of spot size.

physics.ins-det