Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors

Abstract

Experimental TCAD calibration is essential for predictive technology modeling of emerging oxide semiconductor transistors. However, it remains time-consuming and expert dependent because of model ambiguity. Multiple physical models and parameter sets can reproduce the same measured transfer characteristics, while local fitting alone cannot uniquely identify the underlying device physics. We present the first demonstration of an agentic TCAD calibration workflow for a fabricated bottom-gate In--W--O (BG-IWO) transistor. Starting from the measured transfer curve and device information, the workflow uses measurement--TCAD residuals and local sensitivity tests to select bounded parameter corrections or evaluate additional physical models, and accept only updates that improve device metrics. The LLM agent orchestrates the workflow, while Sentaurus governs the device physics. For the 2\%-W reference device, five agent-suggested updates yield a fixed calibrated model, reducing the multi-metric device objective $J$ by 14.3$\times$. Maximum $V_{\mathrm{th}}$/$I_{\mathrm{on}}$ errors are 36.1~mV/0.022 decade for varying-drain-bias tests and 46.2~mV/0.062 decade for varying-channel-length tests, demonstrating model transferability across bias and geometry rather than a local parameter fit. W-composition tests provide process-sensitive insight. This agentic workflow provides a faster route to model development for emerging device technologies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gyujun Jeong, Junmo Lee, Sungwon Cho, Woohyun Hwang, Kwangyou Seo, Suhwan Lim, Wanki Kim, Daewon Ha, Rishi Ranade, Kihang Youn, Ram Cherukuri, Yiyi Wang, Asif Khan, Shimeng Yu. 2026-09-14. Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors. https://arxiv.org/abs/2609.12184

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Nuclear Data Needs for Microcalorimetry and Non-destructive Assay

Cryogenic microcalorimeters are state-of-the-art radiation detectors using superconducting and quantum technologies. They can resolve complex X-ray and low-energy γ-ray spectra with ultra-high energy resolution of an order of 10 eV at 100 keV, enabling high-precision non-destructive assay (NDA) analysis of nuclear materials containing uranium, plutonium and other actinides. With significant technical advancements in microcalorimetry technology, microcalorimeters are now deployable to end-users such as the International Atomic Energy Agency (IAEA) for improved NDA. However, the accuracy of microcalorimetry analysis can be limited by nuclear data. There are several cases that the current nuclear data obtained by conventional radiation detector technologies is not sufficient to support microcalorimetry analysis. To address the growing need for improved nuclear data in microcalorimetry, the U.S. Department of Energy Office of International Nuclear Safeguards hosted a workshop on Microcalorimetry and Nuclear Data (MiND) in June 2023. Microcalorimetry experts and users, and nuclear structure evaluators and managers, and program sponsors attended the workshop with the main objective of identifying a roadmap for priority nuclear data, stakeholders, partnerships, and opportunities. This paper summarizes the outcome of the MiND workshop, including the priority list of nuclear data for microcalorimetry and a multi-laboratory measurement campaign to improve such nuclear data.

physics.ins-det

Cyclotron-Frequency Stability via Single-Ion Fluorescence in a Penning Trap with a Cryogen-Free Superconducting Magnet

In this work, we investigate the magnetic-field stability of a Penning trap operated with a cryogen-free superconducting magnet through cyclotron-frequency measurements of a single laser-cooled calcium ion using two complementary photon-based detection techniques: a pulsed optical method for determining the three ion eigenfrequencies and Fluorescence-Detected Fourier-Transform Ion-Cyclotron-Resonance (FD-FT-ICR). For the former technique, the data-analysis procedure was revisited, considering it as the dominant contribution to the measurement uncertainty and yielding a long-term magnetic-field drift $(1/B)(dB/dt) = -3.07(32)\times10^{-9}$ $\mathrm{h}^{-1}$. This value is comparable to those reported for high-precision Penning-trap experiments employing liquid-helium-based superconducting magnets. The short-term stability was investigated using the FD-FT-ICR technique, resulting in a minimum relative magnetic-field variation of $δB/B \simeq 5\times10^{-8}$ for averaging times between 30 and 60 s. Furthermore, this technique enables direct cyclotron-frequency determinations on timescales as short as a few seconds, providing access to magnetic-field fluctuations that are generally not resolved in conventional Penning-trap experiments.

physics.ins-det

Deep-learning-based low-energy trigger algorithms for the Hyper-Kamiokande experiment

Modern machine learning techniques have become increasingly important in particle physics because of their powerful pattern-recognition capabilities, including in real-time data acquisition where stringent runtime constraints apply. This paper details the performance of deep-learning-based trigger algorithms for a large water Cherenkov detector such as Hyper-Kamiokande, aimed at low-energy neutrino events (below 7 MeV). The performance of custom neural-network supervised classifiers is shown alongside two anomaly-detection approaches trained solely on detector noise: a pure autoencoder and a model based on Manifold Projection-Diffusion Recovery. The supervised model shows signal identification efficiencies of 76.7% for single electrons of 3 MeV kinetic energy, significantly exceeding signal efficiencies obtained from a traditional hit-count-based trigger of 26.4%, while the Manifold Projection-Diffusion Recovery approach reaches 35.4% at the same operating point. Runtime evaluations on GPU yield per-window inference latencies well below the millisecond scale.

physics.ins-det