The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurements. A Micromegas-based neutron detector with two variants was specially developed to measure the beam spot distribution for this beam line. In this article, the design, fabrication, and characterization of the detector are described. The results of the detector performance tests are presented, which include the relative electron transparency, the gain and the gain uniformity, and the neutron beam profile reconstruction capability. The result of the first measurement of the Back-n neutron beam spot distribution is also presented.

Explore related subjects

Keep this discovery

BibTeXRIS

Binbin Qi, Yang Li, Danyang Zhu, Zhiyong Zhang, Ruirui Fan, Jiang Pan, Jianxin Feng, Chengming Liu, Changqing Feng, Jianbei Liu, Ming Shao, Yi Zhou, Yanfeng Wang, Han Yi, Qi An, Huaiyong Bai, Jie Bao, Ping Cao, Qiping Chen, Yonghao Chen, Pinjing Cheng, Zengqi Cui, Minhao Gu, Fengqin Guo, Changcai Han, Zijie Han, Guozhu He, Yongcheng He, Yuefeng He, Hanxiong Huang, Weiling Huang, Xiru Huang, Xiaolu Ji, Xuyang Ji, Haoyu Jiang, Wei Jiang, Hantao Jing, Ling Kang, Mingtao Kang, Bo Li, Lun Li, Qiang Li, Xiao Li, Rong Liu, Shubin Liu, Xingyan Liu, Guangyuan Luan, Yinglin Ma, Changjun Ning, Jie Ren, Xichao Ruan, Zhaohui Song, Hong Sun, Xiaoyang Sun, Zhijia Sun, Zhixin Tan, Hongqing Tang, Jingyu Tang, Pengcheng Wang, Qi Wang, Taofeng Wang, Zhaohui Wang, Zheng Wang, Jie Wen, Zhongwei Wen, Qingbiao Wu, Xiaoguang Wu, Xuan Wu, Likun Xie, Yiwei Yang, Li Yu, Tao Yu, Yongji Yu, Guohui Zhang, Jing Zhang, Linhao Zhang, Liying Zhang, Qingming Zhang, Qiwei Zhang, Xianpeng Zhang, Yuliang Zhang, Yingtan Zhao, Liang Zhou, Zuying Zhou, Kejun Zhu, Peng Zhu. 2019-08-06. Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector. https://doi.org/10.1016/j.nima.2020.163407

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det