An Indirect Dark Matter Search Using Cosmic-Ray Antiparticles with GAPS

Abstract

Experiments aiming to directly detect dark matter (DM) particles have yet to make robust detections, thus underscoring the need for complementary approaches such as searches for new particles at colliders, and indirect DM searches in cosmic-ray spectra. Low energy (< 0.25 GeV/n) cosmic-ray antiparticles such as antideuterons are strong candidates for probing DM models, as the yield of these particles from DM processes can exceed the astrophysical background by more than two orders of magnitude. The General Antiparticle Spectrometer (GAPS), a balloon borne cosmic-ray detector, will perform an ultra-low background measurement of the cosmic antideuteron flux in the regime < 0.25 GeV/n, which will constrain a wide range of DM models. GAPS will also detect approximately 1000 antiprotons in an unexplored energy range throughout one long duration balloon (LDB) flight, which will constrain < 10 GeV DM models and validate the GAPS detection technique. Unlike magnetic spectrometers, GAPS relies on the formation of an exotic atom within the tracker in order to identify antiparticles. The GAPS tracker consists of ten layers of lithium-drifted silicon detectors which record dE/dx deposits from primary and nuclear annihilation product tracks, as well as measure the energy of the exotic atom deexcitation X-rays. A two-layer, plastic scintillator time of flight (TOF) system surrounds the tracker and measures the particle velocity, dE/dx deposits, and provides a fast trigger to the tracker. The nuclear annihilation product multiplicity, deexcitation X-ray energies, TOF, and stopping depth are all used together to discern between antiparticle species. This presentation provided an overview of the GAPS experiment, an update on the construction of the tracker and TOF systems, and a summary of the expected performance of GAPS in light of the upcoming LDB flight from McMurdo Station, Antarctica in 2020.

Explore related subjects

Keep this discovery

BibTeXRIS

Alexander Lowell, Tsuguo Aramaki, Ralph Bird, Mirko Boezio, Steven Boggs, Rachel Carr, William Craig, Philip von Doetinchem, Lorenzo Fabris, Hideyuki Fuke, Florian Gahbauer, Cory Gerrity, Charles Hailey, Chihiro Kato, Akiko Kawachi, Masayoshi Kozai, Isaac Mognet, Kazuoki Munakata, Shun Okazaki, Rene Ong, Guiseppe Osteria, Kerstin Perez, Sean Quinn, Valerio Re, Field Rogers, Jamie Ryan, Nathan Saffold, Yuki Shimizu, Achim Stoessl, Atsumasa Yoshida, Tetsuya Yoshida, Gianluigi Zampa, Jeffrey Zweerink. 2018-12-12. An Indirect Dark Matter Search Using Cosmic-Ray Antiparticles with GAPS. https://arxiv.org/abs/1812.04800

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det