arXiv ScienceSearch

arXiv · 1806.09258

Readout Electronics for CBM-TOF Super Module Quality Evaluation

Abstract

A super module assembled with MRPC detectors is a component of TOF (Time of Flight) system for the Compressed Baryonic Matter (CBM) experiment. Before the super modules are applied to CBM-TOF, their quality needs to be evaluated. The readout electronics is confronted with a tremendous challenge of transmitting data at the maximal speed of 6 Gbps. In this paper, the readout method for CBM-TOF super module quality evaluation is presented. A parallel architecture based on the Gigabit Ethernet is designed to meet the requirement for data transmission rate. First, the data is sent from the front-end electronics to four readout module groups via optical fibers at the maximal rate of 1.5 Gbps per fiber. Next, the data are further distributed to sixteen parallel daughter readout models so that the maximal data throughput of each daughter readout module is 375 Mbps, within its capacity of 550 Mbps. Finally, the readout daughter modules send data to the data acquisition (DAQ) software through standard Gigabit Ethernet. The proposed readout method has the advantage of good scalability, so it can meet different requirements for variable data rate. The preliminary test result shows that each of four parallel readout groups can transmit data at the speed of 1.6 Gbps, which indicates that the overall readout system can meet the requirement for the maximal data-transmission speed of 6 Gbps.

Explore related subjects

Keep this discovery

BibTeXRIS

Wei Jiang, Xiru Huang, Ping Cao, Chao Li, Junru Wang, Jiawen Li, Jianhui Yuan, Qi An. 2018-06-25. Readout Electronics for CBM-TOF Super Module Quality Evaluation. https://doi.org/10.1109/tns.2019.2900657

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det