arXiv ScienceSearch

arXiv · 1804.10978

Optimization based evaluation of grating interferometric phase stepping series and analysis of mechanical setup instabilities

Abstract

The diffraction contrast modalities accessible by X-ray grating interferometers are not imaged directly but have to be inferred from sine like signal variations occurring in a series of images acquired at varying relative positions of the interferometer's gratings. The absolute spatial translations involved in the acquisition of these phase stepping series usually lie in the range of only a few hundred nanometers, wherefore positioning errors as small as 10nm will already translate into signal uncertainties of one to ten percent in the final images if not accounted for. Classically, the relative grating positions in the phase stepping series are considered input parameters to the analysis and are, for the Fast Fourier Transform that is typically employed, required to be equidistantly distributed over multiples of the gratings' period. More general optimization based approaches with relaxed requirements on the sampling positions are often deemed too time consuming in contrast. In the following, a fast converging optimization scheme is presented simultaneously determining the phase stepping curves' parameters as well as the actually performed motions of the stepped grating, including also erroneous rotational motions which are commonly neglected. While the correction of solely the translational errors along the stepping direction is found to be sufficient with regard to the reduction of image artifacts, the possibility to also detect minute rotations about all axes proves to be a valuable tool for system calibration and monitoring. The simplicity of the provided algorithm, in particular when only considering translational errors, makes it well suitable as a standard evaluation procedure also for large image series.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jonas Dittmann, Andreas Balles, Simon Zabler. 2018-04-29. Optimization based evaluation of grating interferometric phase stepping series and analysis of mechanical setup instabilities. https://doi.org/10.3390/jimaging4060077

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Development of an Extensible Unified Control System Using the STARS Framework and Common Commands for Detector Control

A zooming optical system comprising two Fresnel zone plates (FZPs) was developed and installed at the AR-NE1A beamline of the Photon Factory, High Energy Accelerator Research Organization (KEK), Japan. To ensure reliable and versatile operation, we implemented a dedicated control architecture based on the Simple Transmission and Retrieval System (STARS) framework and the newly proposed STARS Common Commands for Detector Control (CCDC)---a data-acquisition (DAQ) state model and command set designed specifically for detector control. The system serves both as a practical control system for the zooming optics and as a demonstration of modular extensibility using STARS and detector interoperability through CCDC. The system has been commissioned, and its performance has been verified at the AR-NE1A beamline. The architecture enables flexible configuration of optical components and provides a unified interface for both routine operation and advanced experimental protocols.

physics.ins-det

Agentic TCAD Calibration Workflow for Oxide Semiconductor Transistors

Experimental TCAD calibration is essential for predictive technology modeling of emerging oxide semiconductor transistors. However, it remains time-consuming and expert dependent because of model ambiguity. Multiple physical models and parameter sets can reproduce the same measured transfer characteristics, while local fitting alone cannot uniquely identify the underlying device physics. We present the first demonstration of an agentic TCAD calibration workflow for a fabricated bottom-gate In--W--O (BG-IWO) transistor. Starting from the measured transfer curve and device information, the workflow uses measurement--TCAD residuals and local sensitivity tests to select bounded parameter corrections or evaluate additional physical models, and accept only updates that improve device metrics. The LLM agent orchestrates the workflow, while Sentaurus governs the device physics. For the 2\%-W reference device, five agent-suggested updates yield a fixed calibrated model, reducing the multi-metric device objective $J$ by 14.3$\times$. Maximum $V_{\mathrm{th}}$/$I_{\mathrm{on}}$ errors are 36.1~mV/0.022 decade for varying-drain-bias tests and 46.2~mV/0.062 decade for varying-channel-length tests, demonstrating model transferability across bias and geometry rather than a local parameter fit. W-composition tests provide process-sensitive insight. This agentic workflow provides a faster route to model development for emerging device technologies.

physics.ins-det

Birefringence of AlGaAs/GaAs Coatings under Above-Band-Gap Illumination, GR Noise and Photo-Optic Transfer Function

AlGaAs/GaAs coatings are being considered as coating candidates for gravitational-wave detectors. In this paper we investigate the birefringence properties of this crystalline semiconductor material by modulating the optical illumination on the mirror coating and monitoring the induced birefringence. While the measured low-frequency birefringence values align with previous studies, we observed a frequency-dependent behavior in the illumination-to-birefringence coupling, characterized by a pole increasing with illumination intensity and a gain at zero frequency (DC gain) decreasing with illumination intensity. We developed a generic theoretical model based on a master equation to characterize the measurement results by considering photon-induced electric fields and electro-optic effects. This model can fit the frequency and intensity dependencies of the induced birefringence. Additionally, this model predicts a generation-recombination noise (GR noise) will be observable in the coating birefringence. While the presented measurement cannot predict the exact level of GR noise, for the frequency band and spot sizes relevant for gravitational-wave detectors we expect GR noise to be white below the pole frequency, scale with power the same way laser shot noise does, and for fixed power be independent of spot size.

physics.ins-det