arXiv · 1601.06955
Test of \textit{Topmetal-${II}^-$} In Liquid Nitrogen For Cryogenic Temperature TPCs
Abstract
\textit{Topmetal-${II}^-$} is a highly pixelated direct charge sensor that contains a 72${\times}$72 pixel array of 83$μ$m pitch size. The key feature of \textit{Topmetal-${II}^-$} is that it can directly collect charges via metal nodes of each pixel to form two-dimensional images of charge cloud distributions. \textit{Topmetal-${II}^-$} was proved to measure charged particles without amplification at room temperature. To measure its performance at cryogenic temperature, a \textit{Topmetal-${II}^-$} sensor is embedded into a liquid nitrogen dewar. The results presented in this paper show that \textit{Topmetal-${II}^-$} can also operate well at this low temperature with a noise (ENC) of 12 e$^-$ lower than that at room temperature (13 e$^-$). From the noise perspective, \textit{Topmetal-${II}^-$} is a promising candidate for the next generation readout of liquid argon and xenon Time Projection Chamber (TPC) used in experiments searching for neutrinoless double beta decay and dark matter.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Shuguang Zou, Yan Fan, Mangmang An, Chufeng Chen, Guangming Huang, Xiaoting Li, Jun Liu, Hua Pei, Xiangming Sun, Ping Yang, Dong Wang, Le Xiao, Zhen Wang, Kai Wang, Wei Zhou. 2016-06-07. Test of \textit{Topmetal-${II}^-$} In Liquid Nitrogen For Cryogenic Temperature TPCs. https://doi.org/10.1016/j.nima.2016.05.125
Cite the original work for its findings. Save a collection to share your selection of sources.