arXiv ScienceSearch

SEARCH · arXiv Science

Results for “math.CT”

Search indexed arXiv papers on artificial intelligence, large language models, computer vision and robotics. Read source abstracts and follow links to arXiv.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

630 records · Page 2Linked to original sources

Parallel Reference-Centric Continuous-Time Relative Localization with Augmented Clamped Non-Uniform B-Splines

Accurate relative localization is critical for multi-robot cooperation. In robot groups, measurements from different robots arrive asynchronously and with clock time-offsets. Although Continuous-Time (CT) formulations have proved effective for handling asynchronous measurements in single-robot SLAM and calibration, extending CT methods to multi-robot settings faces great challenges in achieving high-accuracy, low-latency, and high-frequency performance. In particular, existing CT methods suffer from the inherent query-time delay of unclamped B-splines and high optimization latency. This paper proposes CT-RIO, a novel Continuous-Time Relative-Inertial Odometry framework. We adopt Clamped Non-Uniform B-splines (C-NUBS) to represent states, eliminating the query-time delay. We further augment C-NUBS with closed-form extension and shrinkage operations that preserve the spline shape, making it suitable for online estimation and enabling flexible knot management. This flexibility leads to the concept of a knot-keyknot strategy, which supports spline extension at high frequency while retaining sparse keyknots for adaptive relative motion modeling. We then formulate a reference-centric sliding-window relative localization problem that operates purely on relative kinematics and inter-robot constraints. To enable low-latency and high-frequency estimation, we decompose the tightly coupled optimization into robot-wise subproblems and solve them in parallel using asynchronous block coordinate descent. Extensive experiments show that CT-RIO converges from time-offsets as large as 264 ms to sub-millisecond within 3 s, and achieves RMSEs of 0.046 m and 1.8 degree. It consistently outperforms evaluated published methods, with improvements of up to 60% under high-speed motion.

cs.RO

Continuous-Time Aggregation of Massive Flexible HVAC Loads Considering Uncertainty for Reserve Provision in Power System Dispatch

Heating, ventilation, and air conditioning (HVAC) loads, with their rapid response capabilities, can provide considerable intra-hour flexibility on the demand side for reserve provision in order to follow the fast variations of renewables. However, scheduling massive HVACs is challenging due to computation complexity and the uncertainty of outdoor temperature. In this paper, we first introduce a novel continuous-time (CT) aggregation model to reveal the potential intra-hour flexibility of HVACs. For accurate aggregation, a new affine transformation is designed to handle the heterogeneity in high-dimensional feasible region. Further, for reliable aggregation in practical environment, the outdoor temperature uncertainty is constructed by distributionally robust chance constrains and integrated into the aggregation model. Secondly, for the tractable calculation of the proposed CT aggregation model, a cascade of tailored reformulation techniques is proposed, including the Bernstein polynomial spline, polytope projection, and linearization transformation. Thirdly, a customized hierarchical dispatch framework is proposed via incorporating the proposed CT aggregation model into reserve provision in power system dispatch, so as to efficiently schedule massive HVACs to cope with the renewable uncertainty. Case studies verify the effectiveness and scalability of the proposed CT aggregation model in aggregation accuracy, intra-hour flexibility utilization, and uncertainty handling.

eess.SY

Sense Once, Serve Many: Common-Trace Factorized Constrained PPO for Online Sensing-Session Consolidation in Multi-Tenant ISAC Networks

Integrated sensing and communication (ISAC) networks can serve compatible requests through shared sensing sessions, but consolidation couples admission, reuse, profile selection, sensing service-level agreements (SLAs), communication quality of service (QoS), and future commitments. We formulate this problem as a constrained Markov decision process and propose Common-Trace Factorized Constrained Proximal Policy Optimization (CT-PPO). During training, stochastic policy replicas share the same primitive workload trace; leave-one-out discounted Monte Carlo return contrasts provide reward credit to applicable actor factors, while constraint credit remains factor/prefix-specific. Across five training seeds and matched workloads, CT-PPO achieves the highest mean macro return, exceeding matched Joint-Credit PPO (JC-PPO) by 0.934 (95% confidence interval [0.702, 1.164]) and SLA-Aware Greedy by 1.847; versus JC-PPO, it reduces sensing-resource cost by 6.277 and raises accepted requests per created session by 0.0806. A four-way ablation shows that the factorized surrogate alone yields no detectable macro-return gain, whereas adding common-trace reward credit produces the dominant improvement. Without retraining, CT-PPO retains a return advantage at low, nominal, and high arrival loads, with the strongest gain under clustered arrivals. Deployment uses public observations and hard masks; CT-PPO's extra parameters are training-side, its actor footprint matches JC-PPO, and actor-only CPU latency is effectively unchanged.

cs.NI

Beyond Transfer Accuracy: Mechanism-Guided Controlled Adaptation for Low-Resource Languages

Existing circuit discovery methods rely on templated tasks with clean counterfactuals, limiting their use on diverse natural text. We adapt Contextual Decomposition for Transformers (CD-T) for unstructured settings via label-balanced activation means and task-directional relevance scoring, enabling counterfactual-free circuit discovery. We leverage the discovered circuits for Circuit-Targeted Supervised Fine-Tuning (CT-SFT), restricting parameter updates to task-relevant heads and LayerNorm. Experiments on NusaX cross-lingual sentiment transfer show that CT-SFT is highly competitive for low-resource adaptation. While non-circuit sparse updates and full fine-tuning sometimes match target accuracy through capacity recruitment, CT-SFT most consistently avoids catastrophic forgetting, preserving source-language and related-task performance. Extensions to XNLI support the source-retention and intervention findings on a harder task and two model families, showing that circuit-targeted adaptation provides a more controlled, intervention-supported alternative to global fine-tuning.

cs.CL

Report Supervision

Segmentation models can surpass radiologists, classification models, and vision-language models in tumor detection. Importantly, segmentation models outline tumors, allowing radiologists to better verify and trust the AI output. Their main limitation is the scarcity of tumor masks: creating one 3D tumor mask takes up to 30 minutes, so most public CT datasets contain only a few hundred masks, and even the largest private datasets contain only a couple of thousand. Tumor masks are not produced in clinical routine, but radiology reports are. Public datasets contain tens of thousands of CT-Report pairs, and hospitals contain hundreds of thousands. These reports describe tumors in detail, providing large-scale, informative training data. Here, we introduce Report Supervision (R-Super), a training framework that uses reports to directly supervise and improve tumor segmentation. R-Super introduces new loss functions that teach segmentation models to segment tumors that match report descriptions of tumor count, sizes, and locations. Reports are only used for training. We evaluated R-Super on kidney and pancreatic tumor segmentation, exploring diverse training data sizes, up to 41,418 CT-Report plus 3,488 pancreatic tumor CT-Mask pairs. On external validation, R-Super increased tumor detection F1-Score and segmentation DSC by up to +15% with respect to mask-only training. It also surpassed alternative methods such as CLIP and multi-task learning. Leveraging numerous readily available reports to supplement scarce masks, R-Super strongly improves AI performance when very few training masks are available (e.g., 50), and when many masks are available (e.g., 3,488), unlocking scale in tumor segmentation.

cs.CV

WorldBench: Culturally Grounded Benchmark for Multilingual Agents

Despite the growing use of LLM-powered agents to solve multi-step tasks in complex environments, existing benchmarks rarely test state preservation, performance across languages, and application to realistic, grounded scenarios. To address these concerns, we present WorldBench: a comprehensive, multilingual benchmark of genuine, persona-grounded everyday workflows, where agents can act in a sandbox via structured actions. WorldBench comprises 1,600 tasks across seven languages and eight cultures, filtered and refined through feedback from human annotators with language- and culture-specific expertise. For evaluation, we extend metrics from previous works and introduce Constrained Task Success (CTS), which combines natural language instructions and testbeds to score task completion, minimal modification, and other complementary metrics through deterministic and LLM-as-a-Judge evaluations. Our experiments show that frontier models reach only 49.2% CTS, with all models demonstrating large gaps between correctness and environment preservation. We thereby show that current agents remain brittle in multilingual, agentic scenarios, especially for long-horizon tasks and under state-preservation constraints

cs.AI

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

cs.CV

Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations

Interpreting a CT scan means comparing structures on either side, judging how far apart organs sit, and knowing where each one belongs. Medical vision encoders are evaluated on diagnostic accuracy, or through assembled multimodal systems where a failure is hard to attribute, so it remains unclear whether their representations support any of this. We construct SPAR-Bench, eight probes over multi-organ abdominal CT that separate coordinate localization, relational reasoning, and spatial queries, and apply them to five architectural configurations and three medical foundation models, frozen and finetuned. Probes that ask for a comparison within the slice stay at chance, and neither pretraining scale, finetuning, nor architecture closes the gap. Probes that appear solved in domain fall to chance under zero-shot transfer, indicating that their accuracy reflects recall of canonical anatomy rather than computation over the image. Reading the same frozen features with a pooled head rather than the full set of tokens moves relational recovery from 0.7% to 67.8%, so pooled probing understates what a representation holds. Questions the encoders answer well are answered at chance by four open-weight MLLMs. Our results suggest these encoders carry a map of where organs usually lie, and little of the machinery for comparing structures within a particular patient. Code and data will be available at https://spar-bench.github.io.

eess.IV

Pretrained, Curriculum-Tuned, and Ensembled: A Tracer-Aware Interactive Segmentation Pipeline for AutoPET V

Interactive lesion segmentation in whole-body PET/CT requires a model to provide a strong initial prediction while also responding efficiently to sparse corrective scribbles during inference. This setting is particularly challenging because tracer distributions, physiological uptake patterns, lesion appearance, and acquisition characteristics differ substantially between FDG and PSMA studies. We present TRIAGE, Tracer-aware Refinement via Interactive Anatomy-Guided sEgmentation. The core backbone is a 3D STU-Net initialized through masked autoencoding pre-training with an asynchronous masking strategy, aiming to learn transferable anatomical and cross-modal representations before task-specific fine-tuning. In parallel, we train an auxiliary organ segmentation model whose predictions provide explicit anatomical context and help distinguish physiological uptake from malignant lesions. A dedicated tracer classifier first routes each study to an FDG- or PSMA-specific branch. Within each branch, a first-stage segmentation model consumes CT, PET, and organ context to generate an initial lesion mask. The initial prediction is then combined with cumulative foreground/background scribbles and refined by a second interactive segmentation network. The FDG and PSMA branches share the same overall processing pipeline but are trained independently to account for tracer-specific appearance and error modes. We additionally employ curriculum-style training and model ensembling to improve robustness across interaction steps and heterogeneous cohorts. Experiments are conducted using the official AutoPET V data and ten-fold split; quantitative results, ablations, and final test-set performance are left as placeholders to be completed after the challenge evaluation. Code: https://github.com/Liiiii2101/AUTOPET2026-MEDAI.

cs.CV

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $Δ$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

eess.IV

SGRNet: Spatially Guided Radiology Network for Structured Radiological Reporting of Head and Neck Cancer

Automated radiological report generation can alleviate clinical workloads and eliminate observer variability. However, standard free-text generation models pose hallucination risks in dense regions and fail under data scarcity. We address these challenges in Head and Neck Cancer (HNC) from contrast-enhanced CT (CECT) imaging. To enforce factual safety, we reformulate report generation as an anatomically grounded, multi-label, structured reporting task, predicting localized tumor involvement across a hierarchical clinical schema. To bridge the visual gap from missing metabolic imaging (e.g., PET), we introduce SGRNet (Spatially Guided Radiology Network), incorporating two low-cost spatial priors: automated organ segmentations and weakly supervised tumor localization maps modeled via 3D Gaussian heatmaps. These priors are dynamically integrated via spatial feature modulation to guide the network toward subtle tumor-induced structural alterations. Evaluated on a multi-centric dataset of 184 paired HNC CECT volumes and reports, on five clinically salient, densely packed anatomical subsites, SGRNet achieves a mean Average Precision (mAP) of 0.60, an 8.8 percentage-point absolute improvement over strong volume-only 3D baselines.

cs.CV

Anatomy-Aware Promptable Segmentation with Online Interactive Training for AUTOPET V

We present an anatomy-aware, promptable model for whole-body lesion segmentation in FDG and PSMA PET/CT, developed for the AUTOPET V challenge. The proposed method is built as family of nnU-Net-based models and trained in two stages: i) a pre-training stage that produces a strong initial segmentation, and ii) an online interactive stage that learns to exploit scribble prompts, refining the prediction over successive interactions. Anatomical context is incorporated through organ supervision using a single shared head that predicts lesions and organs from the same features, which reduces false positives arising from physiological uptake. Also as the tracer (i.e., FDG/PSMA) is not provided at inference, we add a tracer classifier based on image processing and a random forest over coronal MIP features, routing each study to a combined FDG+PSMA model or to a PSMA-specific model. Across four-fold cross-validation the organ-supervised model achieves the best and most stable performance, the interactive stage improves the Dice score monotonically with each prompt, and PSMA-specific training yields the strongest tracer-wise results.

cs.CV

Variational Autoencoders for Feature Exploration and Malignancy Prediction of Lung Lesions

Lung cancer is responsible for 21% of cancer deaths in the UK and five-year survival rates are heavily influenced by the stage the cancer was identified at. Recent studies have demonstrated the capability of AI methods for accurate and early diagnosis of lung cancer from routine scans. However, this evidence has not translated into clinical practice with one barrier being a lack of interpretable models. This study investigates the application Variational Autoencoders (VAEs), a type of generative AI model, to lung cancer lesions. Proposed models were trained on lesions extracted from 3D CT scans in the LIDC-IDRI public dataset. Latent vector representations of 2D slices produced by the VAEs were explored through clustering to justify their quality and used in an MLP classifier model for lung cancer diagnosis, the best model achieved state-of-the-art metrics of AUC 0.98 and 93.1% accuracy. Cluster analysis shows the VAE latent space separates the dataset of malignant and benign lesions based on meaningful feature components including tumour size, shape, patient and malignancy class. We also include a comparative analysis of the standard Gaussian VAE (GVAE) and the more recent Dirichlet VAE (DirVAE), which replaces the prior with a Dirichlet distribution to encourage a more explainable latent space with disentangled feature representation. Finally, we demonstrate the potential for latent space traversals corresponding to clinically meaningful feature changes.

cs.CV

Agentic Large Language Models for Training-Free Neuro-Radiological Image Analysis

State-of-the-art large language models (LLMs) show high performance in general visual question answering. However, a fundamental limitation remains: current architectures lack the native 3D spatial reasoning required to directly analyze volumetric medical imaging, such as CT or MRI. Emerging agentic AI offers a new solution, eliminating the need for intrinsic 3D processing by enabling LLMs to orchestrate and leverage specialized external tools. Yet, the feasibility of such agentic frameworks in complex, multi-step radiological workflows remains underexplored. In this work, we present a training-free agentic pipeline for automated brain MRI analysis. Validating our methodology on several LLMs (GPT-5.4, Gemini 3.1 Pro, Claude Sonnet 4.6) with off-the-shelf domain-specific tools, our system autonomously executes complex end-to-end workflows, including preprocessing (skull stripping, registration), pathology segmentation (glioma, meningioma, metastases), and volumetric reasoning. We evaluate our framework across increasingly complex radiological tasks, from single-scan tumor and anatomy analysis to longitudinal response assessment requiring multi-timepoint comparisons. We analyze the impact of architectural design by comparing single-agent models against multi-agent "domain-expert" collaborations. To support rigorous evaluation of future agentic systems, we release a benchmark dataset of image-prompt-answer tuples derived from public data. Our results demonstrate that agentic AI can solve highly neuro-radiological image analysis tasks through tool use without the need for training or fine-tuning.

cs.CV

PyDoseRT Proton: A GPU Pencil-Beam Engine with a Convolutional Residual-Correction Network for Fast Proton Dose Calculation

Architecture category. Hybrid method: a physics-based analytical pencil-beam (PB) dose engine followed by a 3-D convolutional residual-correction network (RepVGG-U-Net). We addressed the DoseRAD2026 proton dose-prediction task with PyDoseRT Proton, a GPU-accelerated engine implemented in PyTorch and augmented by a learned residual toward Monte Carlo (MC) accuracy. A double-Gaussian PB kernel was calibrated to GATE/Geant4 integrated depth doses in water in two stages: a classical per-energy curve fit, then a gradient-based fit of the full 3-D dose through the PyTorch physics engine as it retains a differentiable execution path for gradient-based optimization of dose-dependent objectives. The engine computes each beamlet on a beam's-eye-view (BEV) lattice with variance-preserving Gaussian splitting, an analytic nuclear halo, and a Fermi-Eyges heterogeneity term, then rotates the result into the patient frame. Additionally, a compact residual U-Net predicts an additive correction in BEV space. It is conditioned on voxelwise material-label embeddings, a discrete energy embedding and spot size. The same model was used for all anatomical sites (thoracic and abdominal). It was trained with a patient-space L1 objective emphasizing the scored high-dose region and multi-scale BEV deep supervision. The submitted CT configuration obtained preliminary-test beamlet MAE 0.0066, image-z IDD distance 0.0025, plan MAE 0.0049, 98.30\% gamma pass rate (1\%/1 mm), and DVH error 0.460.

physics.med-ph

RAFT-DVC: Resolution-Aware Machine Learning-Based Digital Volume Correlation

Digital volume correlation (DVC) provides three-dimensional full-field displacement measurements from volumetric images, but how the internal resolution of a machine-learning-based DVC model affects accuracy and operating range remains poorly understood. Here, we present RAFT-DVC, a resolution-aware family of recurrent all-pairs field transforms (RAFT)-based DVC solvers with encoder downsampling factors s = 2, 4, and 8. Using a matched design, we find that the three solvers localize displacement to approximately 0.017 feature-grid voxel, giving an empirical raw-volume error scaling of approximately 0.017s voxel. The solvers exhibit complementary operating regimes governed jointly by displacement reach and volumetric-texture compatibility. Synthetic benchmarks show that RAFT-DVC achieves errors of the same order as tuned classical DVC under fine-texture, small-to-moderate-displacement conditions and becomes competitive or advantageous under coarse-texture, large-displacement conditions. Frequency-swept tests quantify deformation spatial resolution, while tiled inference enables dense estimation on large volumes. Evaluation on confocal volumetric images acquired during indentation illustrates the importance of matching solver operating regime to deformation magnitude and image texture. Tests on micro-CT images of elastomeric foam, despite training only on particle-labeled synthetic data, provide evidence of cross-texture transfer. We also identify coordinate-order inconsistencies in three-dimensional RAFT correlation sampling and introduce a non-cubic impulse test to verify sampler geometry independently of network training. Correcting the sampler improves native-input accuracy and generalization to unseen volume dimensions. Together, these results establish RAFT-DVC as a fast, resolution-aware framework for dense DVC with characterized accuracy and operating regimes.

cs.CV

Turing complete Navier-Stokes steady states via cosymplectic geometry

In this article, we construct stationary solutions to the Navier-Stokes equations on certain Riemannian $3$-manifolds that exhibit Turing completeness, in the sense that they are capable of performing universal computation. This universality arises on manifolds admitting nonvanishing harmonic 1-forms, thus showing that computational universality is not obstructed by viscosity, provided the underlying geometry satisfies a mild cohomological condition. The proof makes use of a correspondence between nonvanishing harmonic $1$-forms and cosymplectic geometry, which extends the classical correspondence between Beltrami fields and Reeb flows on contact manifolds.

math.DG

Automated neuroradiological support systems for multiple cerebrovascular disease markers -- A systematic review and meta-analysis

Cerebrovascular diseases (CVD) can lead to stroke and dementia. Stroke is the second leading cause of death world wide and dementia incidence is increasing by the year. There are several markers of CVD that are visible on brain imaging, including: white matter hyperintensities (WMH), acute and chronic ischaemic stroke lesions (ISL), lacunes, enlarged perivascular spaces (PVS), acute and chronic haemorrhagic lesions, and cerebral microbleeds (CMB). Brain atrophy also occurs in CVD. These markers are important for patient management and intervention, since they indicate elevated risk of future stroke and dementia. We systematically reviewed automated systems designed to support radiologists reporting on these CVD imaging findings. We considered commercially available software and research publications which identify at least two CVD markers. In total, we included 29 commercial products and 13 research publications. Two distinct types of commercial support system were available: those which identify acute stroke lesions (haemorrhagic and ischaemic) from computed tomography (CT) scans, mainly for the purpose of patient triage; and those which measure WMH and atrophy regionally and longitudinally. In research, WMH and ISL were the markers most frequently analysed together, from magnetic resonance imaging (MRI) scans; lacunes and PVS were each targeted only twice and CMB only once. For stroke, commercially available systems largely support the emergency setting, whilst research systems consider also follow-up and routine scans. The systems to quantify WMH and atrophy are focused on neurodegenerative disease support, where these CVD markers are also of significance. There are currently no openly validated systems, commercially, or in research, performing a comprehensive joint analysis of all CVD markers (WMH, ISL, lacunes, PVS, haemorrhagic lesions, CMB, and atrophy).

physics.med-ph