arXiv ScienceSearch

SEARCH · arXiv Science

Search arXiv Science

Search indexed arXiv papers on artificial intelligence, large language models, computer vision and robotics. Read source abstracts and follow links to arXiv.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Semantic-Guided Multimodal Preprocessing for Vision Transformer-Based Clear Cell Renal Cell Carcinoma Grading

Clear cell renal cell carcinoma (CCRCC) grading is essential for treatment planning, yet existing approaches either analyze patch-level images directly or focus solely on nuclei-level classification, without linking to final tumor grading. We propose a semantic-guided multimodal preprocessing method that integrates nuclei classification maps from existing pre-trained models with RGB histopathology images for Vision Transformer (ViT)-based CCRCC grading. Our approach employs classification map channel concatenation and multiplicative modulation, with optimized overlays to leverage nuclei grading information, while preserving RGB textural features. Evaluation of multiple preprocessing strategies demonstrates that semantic-guided enhancement achieves 0.916 balanced accuracy, outperforming RGB-only baseline (0.707) and max-voting aggregation from prior studies (0.427). Sensitivity analysis reveals that this 21 percentage point improvement over baseline persists even under simulated perturbation at rates matching current state-of-the-art nuclei classification model error thresholds, suggesting both effective semantic utilization and practical robustness. These findings show that preprocessing-based multimodal fusion can leverage the diagnostic potential of existing imperfect nuclei classifiers, effectively bridging previously isolated fine-grained nuclear-level analysis with coarse-grained ViT-based patch classification. Per-class recall was consistent across grades (0.93, 0.91, 0.91), indicating that gains are not concentrated in the majority class. Because the sensitivity analysis perturbs ground-truth maps rather than predictions from an actual nuclei model, this result characterizes robustness under simulated error rather than deployment with a real upstream model, which remains for future work.

cs.CV

Infrastructure-based Monocular 3D Vehicle Localization Framework with Experimental Validation

This paper presents a one-stage learning framework that maps monocular roadside-camera images directly to vehicle states in a ground-fixed coordinate frame. Unlike conventional approaches that first detect vehicles in the image plane and subsequently apply geometric post-processing, the proposed method leverages features from a pretrained object detector to jointly estimate each vehicle's ground-plane position, dimensions, and yaw angle. The framework therefore uses visual features not only for vehicle detection but also for direct spatial and orientation estimation. To support model training and evaluation, we develop a data-collection and label-generation pipeline based on synchronized video from a roadside camera and an unmanned aerial vehicle (UAV). Acting as a temporary top-view sensing platform, the UAV provides vehicle trajectories, dimensions, and orientations, which are transformed into the ground-fixed coordinate frame and temporally aligned with the roadside-camera images to generate ground-truth labels. The framework is evaluated using data collected during multiple experiments at the Mcity Test Facility. Results show that the proposed method can recover vehicle trajectories and orientations from monocular roadside imagery without a separate geometric post-processing stage, demonstrating its potential as a scalable approach to infrastructure-based perception at urban intersections.

cs.CV

Reliability-Aware Hybrid-K Ensemble Selection for Cervical Cytology Classification: Integrating Discrimination, Calibration, and Selective Prediction

High classification accuracy alone is insufficient for clinical image analysis, where calibrated confidence and reliable uncertainty estimates are essential. This study proposes a reliability-aware Hybrid-K ensemble selection framework for multiclass cervical cytology classification using the SIPaKMeD dataset. Nine deep learning architectures were evaluated using a fixed stratified five-fold partition and three training seeds. After post-hoc temperature scaling, models were assessed using macro-F1, accuracy, AUROC, expected calibration error (ECE), worst-class ECE (WC-ECE), area under the risk-coverage curve (AURC), Brier score, and negative log-likelihood (NLL). Models were ranked using an equal-weight composite score, and Hybrid-K ensembles were formed from the top-ranked models using soft voting. Robustness was examined using 5,000 Dirichlet-sampled metric-weight vectors, leave-one-metric-out analysis, and corrected paired testing across 15 fold-by-seed evaluations. The final Hybrid-2 ensemble, comprising Swin-Tiny and TinyViT-5M, reduced AURC by 43%, NLL by 17%, and WC-ECE by 36% relative to the best individual model. It was selected in 96.8% of random weighting scenarios, remained unchanged across all leave-one-metric-out analyses, and improved the full composite score. However, per-metric gains were not statistically significant after Holm-Bonferroni correction (all adjusted p >= 0.168). Because post-hoc calibration did not use a fully independent calibration set, calibration-dependent results should be interpreted as exploratory internal estimates. Overall, the framework identified a compact ensemble robust to alternative metric weightings and improved reliability point estimates under internal validation on a single dataset.

eess.IV

ReLViC: Loss-Resilient Learned Video Coding with Dispersed Packetization and Controllable Packet Dependencies

Packet loss can severely impair learned video coding because missing latent tokens compromise both spatial reconstruction and temporal prediction. We present ReLViC, a loss-resilient learned video coding framework that jointly addresses latent coding and packet-loss recovery. ReLViC disperses spatially adjacent latent tokens across packets and employs a dual-purpose Transformer to estimate entropy-model parameters during coding and reconstruct missing latent tokens at the receiver. It controls packet dependencies through a periodic-reset packet-context topology parameterized by the segment length, thereby tuning the trade-off between compression efficiency and error-propagation range without retraining. A three-stage progressive training procedure establishes single-frame coding, learns temporal context for entropy modeling, and then optimizes the recovery of masked latent tokens under simulated packet loss. Experiments using burst-loss traces evaluate ReLViC against H.265 protected by Reed--Solomon forward error correction (FEC) and GRACE, a loss-resilient learned video codec. ReLViC delivers more stable reconstruction and outperforms both baselines under severe packet loss.

eess.IV

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

cs.CV

Real-Time Video Anomaly Detection Using YOLO Pose Estimation and CLIP-Based Semantic Scoring

We propose a lightweight two-stage framework for real-time video anomaly detection. The first stage employs YOLO v11n-pose to detect persons and extract seventeen skeletal keypoints in a single forward pass. The second stage encodes each cropped person region through CLIP ViT-B/32 and computes cosine similarity against predefined textual descriptions of anomalous behaviors. This architecture eliminates the need for optical flow, standalone pose estimators, and density-based scoring modules. Experiments on CUHK Avenue, ShanghaiTech Campus, and a custom indoor dataset collected at Chulalongkorn University demonstrate an end-to-end throughput of approximately 51 FPS on an NVIDIA Titan XP GPU, a 3.36x speedup over the multi-feature baseline, while maintaining frame-level AUROC values of 89.26%, 70.26%, and 84.13%, respectively.

cs.CV

Expert-like Bone Ultrasound Segmentation through Expert-in-the-loop Mask-conditioned Progressive Learning

Manual annotation remains a major bottleneck in ultrasound (US) bone segmentation, where experts typically iteratively refine rough brush masks rather than delineating precise contours in a single pass. We present ExiL, a mask-conditioned progressive learning framework that models annotation as a structured refinement trajectory. ExiL combines a synthetic expert-like brush simulator based on signed distance fields with a lightweight 7.8M-parameter U-Net that learns to complete and refine imperfect masks from US images. During deployment, an expert mode updates the model directly from accepted refinements, enabling continual adaptation to expert behavior. Evaluated using UltraBones100k cadaver data for quantitative segmentation and a prospective volunteer dataset for annotation-efficiency analysis, ExiL reduced single-expert average annotation time from 60 to 20 seconds per frame (66.7\%) and improved mean Dice by approximately 0.045 over non-progressive training, while achieving 0.87 Dice and 2.7 px boundary error in the best trajectory-aware setting. With 10--50 ms inference, ExiL enables real-time, self-improving annotation for US-guided orthopedic workflows in practical clinical labeling.

eess.IV

Feature-Spectral Fragility in Segmentation: Dataset Dependence, Architecture-Specific Localization, and Spectral Correlates

Robustness of segmentation models is commonly assessed through input-domain perturbations, while dependence on frequency content within learned feature representations remains less understood. We probe this dependence using targeted post-training low-pass interventions on internal representations of three segmentation architectures, ResNet50-UNet (CNN), VM-UNet (SSM), and Swin-UNETR (Transformer), across CVC-ClinicDB and ISIC2018, with headline evaluations performed on untouched held-out test sets. At cutoff rho=0.25, feature-domain low-pass filtering causes severe degradation on CVC: Dice drops by 100%, 73.2%, and 30.9% for CNN, SSM, and Transformer, respectively, compared with 9.4%, 10.3%, and 0.6% on ISIC. The cross-dataset difference is statistically significant for every architecture. Single-stage interventions further show that sensitivity is localized at architecture-specific depths: the CNN peaks at a mid/late encoder block, whereas the SSM peaks in an early encoder stage on both datasets. Native feature-domain spectral measurements show an inverse association between high-frequency energy and fragility on CVC; the relationship is only partial on ISIC and is therefore treated as a candidate correlate rather than a proven mechanism. Finally, Fourier augmentation improves robustness to input-space low-pass filtering but leaves feature-domain degradation essentially unchanged. These results show that feature-spectral robustness is strongly dataset-dependent, architecture-specific, and distinct from input-domain spectral robustness.

cs.CV

Bayesian-Optimized Superpixel-GrabCut for Traceable Optic Disc Segmentation

Optic disc (OD) segmentation is essential for diagnosing ophthalmic pathologies from retinal fundus images. However, prevailing deep learning approaches operate as opaque black boxes, lacking the inference-stage mathematical traceability--a critical requirement for algorithmic auditing and failure analysis in clinical workflows. This paper presents a fully algorithmically traceable and trainable segmentation pipeline that jointly combines superpixel decomposition, hybrid brightness-proximity superpixel scoring, morphological regularization, iterative GrabCut refinement, and elliptical shape fitting. The hyperparameter optimization is formulated as an objective function and solved via Bayesian optimization to eliminate manual parameter tuning. A quantitative evaluation on the Drishti-GS dataset demonstrates that our method achieves a Dice coefficient of 0.9536, matching state-of-the-art performance. By maintaining explicit mathematical transparency across all processing stages, our framework offers a deterministic, traceable alternative to black-box architectures for medical review and debugging.

cs.CV

The MYOSAIQ Challenge: Myocardial Segmentation with Automated Infarct Quantification

Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Nowadays MI volume quantification is not performed routinely in clinical practice. Numerous deep learning (DL) methods have been developed to automate the segmentation of the myocardium and infarct regions. However, most studies rely on relatively small datasets which typically undergo pre-processing steps to standardize images and focus on a specific phase of myocardial infarction following reperfusion therapy. These limitations have impeded the development of models that are generalizable across diverse conditions and thus suitable for routine clinical use. To advance research and establish benchmarks in generalizable learning for myocardial infarct quantification, this paper presents findings from the Myocardial Segmentation with Automated Infarct Quantification (MYOSAIQ) challenge. The dataset set up for the challenge combines 439 CMR volumes from two multicenter clinical trials, with representative data acquired in acute and chronic phases after acute MI. Data were acquired in 16 centers using MRI scanners from three different vendors. Six teams participated until the end of the challenge, employing various baseline models, data augmentation techniques, and confidence strategies. To enhance the significance of this study, we compare the challengers' results with those of fine-tuned foundation models. Our results indicate that well-designed UNet-based techniques outperform fully automatic foundation models for LGE MR segmentation. While the best methods achieve high-quality and stable delineations of the left ventricle and myocardium under various conditions, they remain improvable in accurately segmenting infarct regions.

eess.IV

Ada-TokenCom: Rate-Adaptive Token Communications via Large-Model-Driven Token Compression and Generation

Token Communications (TokenCom) has recently emerged as a new paradigm in which tokens serve as unified units for communication and computation, enabling efficient multimodal semantic and goal-oriented transmission. In this paper, we develop Ada-TokenCom, a rate-adaptive TokenCom framework based on large autoregressive models, which integrates next-token prediction with arithmetic coding to achieve ultra-low bitrate semantic communication at the token level. We propose a mixed reconstruction/generation scheme, where the transmitter encodes and transmits the highly informative tokens at the beginning of the token sequence leveraging a pre-trained autoregressive large model, while the receiver uses an identical model to predict the rest. Moreover, we design a Lyapunov-based algorithm to dynamically optimize both the source compression rate and the modulation and coding scheme, adapting to time-varying network conditions. Simulation results demonstrate that our proposed Ada-TokenCom framework outperforms both digital and deep joint source-channel coding-based semantic communication baselines.

cs.IT

Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations

Interpreting a CT scan means comparing structures on either side, judging how far apart organs sit, and knowing where each one belongs. Medical vision encoders are evaluated on diagnostic accuracy, or through assembled multimodal systems where a failure is hard to attribute, so it remains unclear whether their representations support any of this. We construct SPAR-Bench, eight probes over multi-organ abdominal CT that separate coordinate localization, relational reasoning, and spatial queries, and apply them to five architectural configurations and three medical foundation models, frozen and finetuned. Probes that ask for a comparison within the slice stay at chance, and neither pretraining scale, finetuning, nor architecture closes the gap. Probes that appear solved in domain fall to chance under zero-shot transfer, indicating that their accuracy reflects recall of canonical anatomy rather than computation over the image. Reading the same frozen features with a pooled head rather than the full set of tokens moves relational recovery from 0.7% to 67.8%, so pooled probing understates what a representation holds. Questions the encoders answer well are answered at chance by four open-weight MLLMs. Our results suggest these encoders carry a map of where organs usually lie, and little of the machinery for comparing structures within a particular patient. Code and data will be available at https://spar-bench.github.io.

eess.IV

CheXtriev: Anatomy-Centered Representation for Case-Based Retrieval of Chest Radiographs

We present CheXtriev, a graph-based, anatomy-aware framework for chest radiograph retrieval. Unlike prior methods focussed on global features, our method leverages graph transformers to extract informative features from specific anatomical regions. Furthermore, it captures spatial context and the interplay between anatomical location and findings. This contextualization, grounded in evidence-based anatomy, results in a richer anatomy-aware representation and leads to more accurate, effective and efficient retrieval, particularly for less prevalent findings. CheXtriv outperforms state-of-the-art global and local approaches by 18% to 26% in retrieval accuracy and 11% to 23% in ranking quality. The code is available at https://github.com/cvit-mip/chextriev.

eess.IV

Lossy Event Compression: From Event Stream Distortion to Task Performance

Event cameras generate asynchronous, sparse data streams with microsecond temporal resolution, but in moderate-to-high motion scenes they can produce as many as hundreds of millions of events per second, creating significant bandwidth and storage challenges. Lossy compression is therefore essential for practical deployment, yet existing event stream distortion metrics fail to reliably predict compression-induced degradation at the task level, forcing codec optimization to rely on expensive task-specific evaluations. To address this gap, this paper introduces two fundamentally different event compression pipelines: i) an aggregation-based pipeline that converts the event stream into polarity-based histogram frames for compression with the conventional image codec JPEG 2000, and ii) a frame-free point cloud-based pipeline that codes events natively as 3D points using the octree-based codec G-PCC. Both pipelines are then assessed within a unified task-driven evaluation framework that relates event stream distortion to downstream application performance across four representative tasks: i) video reconstruction, ii) object detection, iii) optical flow estimation, and a delay-sensitive task iv) asynchronous feature tracking under a reference-relative protocol. Building on this framework, five classification-based distortion metrics are applied to event compression for the first time, to the best of the authors' knowledge, and benchmarked against existing event stream metrics. Experimental results demonstrate that the proposed metrics reliably predict compression-induced task degradation across different coding frameworks. This demonstrates that event stream distortion assessment can be an efficient alternative to repeated task-specific evaluation, providing direct guidance for the development and optimization of future event data coding solutions.

cs.CV

Coronary Mask Guided Registration for Continuous Time 4D Cardiac CT Dataset Construction

Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research. We aim to construct a 4D cardiac CT dataset that is generally suitable to serve as pseudo ground truth. Methods: We propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the ED or ES phase as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction. To capture the motion of both the RCA and other cardiac structures in each registration, CMGR regularizes RCA masks and incorporates them into image-domain registration. Time-continuity is achieved by interpolating the deformation fields for non-reference phases to arbitrary times. Results: CMGR outperformed representative image-domain registration methods in capturing RCA motion and providing reasonable RCA shape, and showed competitive performance in capturing whole-heart motion. Additionally, CMGR reduced motion artifacts from clinical multiphase reconstructions, and intermediate CMGR frames generally provided plausible transitions between discrete cardiac phases. Conclusion: CMGR provides an effective approach for constructing continuous-time 4D cardiac CT datasets. Significance: The dataset can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.

eess.IV

Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction

Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet.

eess.IV

SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression without explicit correspondence constraints. We introduce SCoPE-Reg, combining state-space slice--volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $\mu$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the state of the art (SOTA), reduces peak error on CAMUS by 56% below SOTA ($12.5\!\to\!5.5$ mm), and registers $100\%$ and $80\%$ of frames within $3$ mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. SCoPE-Reg establishes a SOTA in rigid ultrasound SVR: by coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, it becomes viable at native acquisition resolution during intervention, where prior methods trade accuracy, reliability, or frame rate against one another. Supplementary code provided and will be open-sourced upon acceptance.

eess.IV

Evaluating the Effects of Inter-Observer and Model Variability on Radiological Peritoneal Cancer Index Assessment

Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal Cancer Index (rPCI) region segmentation on contrast-enhanced CT, where a consensus definition provides anatomically grounded 3D regions and the clinically used PCI 20 threshold enables decision-level evaluation. Inter-observer variability is quantified across four experts on ten abdominal CT scans, and a published nnU-Net based rPCI segmentation model is benchmarked against this human reference using Dice, HD95, and ASD across all 13 regions. To relate geometric differences to clinical impact, a probabilistic peritoneal metastasis simulation is implemented on majority-vote rPCI maps, propagating region-boundary variability into variability of derived (r)PCI scores and classification at the PCI 20 cutoff. Observers showed high agreement (mean Dice $0.87$), while the model matched human performance in most regions but deviated more in regions 4, 8, and the small-bowel regions (9-12). Across simulations, score differences were typically small (mean $\Delta$rPCI $\approx 0.3$-$0.6$) for both observers and the model, and decision flips occurred predominantly when the reference score was near 20. These results suggest that rPCI-derived scoring is generally robust to typical segmentation variability, while highlighting borderline cases as the main setting where expert review remains essential.

eess.IV