arXiv ScienceSearch

SEARCH · arXiv Science

Search arXiv Science

Search indexed arXiv papers on artificial intelligence, large language models, computer vision and robotics. Read source abstracts and follow links to arXiv.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

87 records · Page 2Linked to original sources

Cross-Dataset Transfer and Reliability of Explainable Artificial Intelligence for RhythmFormer Remote Photoplethysmography

Background. Remote photoplethysmography estimates the cardiovascular pulse from facial video, and its explanations have rested on inspecting heatmaps rather than on quantitative evidence about where a model reads it. We quantified the explanations and asked whether such explanations transfer between datasets and track model performance. Method. We trained eight condition-specific RhythmFormer models on NCKU-rPPG, recorded under three illumination levels, speaking, rotation, and cycling, estimated one heart rate per 5.12-second clip, and set them beside a UBFC-rPPG reproduction. Raw attention, rollout, attention flow, and Beyond Intuition were assessed by skin coverage and the Salience-guided Faithfulness Coefficient (SaCo). Results. Beyond Intuition ranked highest on both datasets, at median coverage 0.789 and SaCo 0.837 on Static level 3 against 0.826 and 0.917 on UBFC-rPPG; lower ranks differed. Within one participant of one condition, neither measure was related to a clip's heart-rate error, waveform correlation, or signal-to-noise ratio on either dataset: 186 of the 252 coefficients fell below $|ρ|=0.10$ and 28 reached $p<0.05$ against the 13 expected by chance. Across the eight scenarios only Beyond Intuition's coverage followed the three performance measures, at $ρ=-0.43$, $+0.57$, and $+0.43$, while the attention-only methods' SaCo ran opposite to each. It failed at 40 lux alone, its median coverage falling to 0.180 and its median SaCo to $-0.178$, whereas motion degraded the estimates far more without such a drop. Conclusions. Skin coverage and SaCo carry information complementary to the performance measures rather than a proxy for them: attributing to the skin does not guarantee an accurate estimate. What an attribution reveals about a condition is where the model looks rather than how faithfully its map is ordered.

cs.CV

Cooperative Multi-Task Semantic Communication for Joint Classification and Regression Tasks

Multi-Task semantic communication (SemCom) prioritizes simultaneous execution of multiple tasks over bit-accurate reconstruction in future intelligent networks. In our prior work [1], we introduced the cooperative multi-task SemCom (CMT-SemCom) framework, in which the semantic encoder is divided into a common unit (CU) and multiple specific units (SUs) to facilitate cooperative multi-task processing. However, CMT-SemCom has been evaluated on homogeneous classification tasks on simplistic datasets, limiting its applicability to real-world perception systems. In this paper, we extend our CMT-SemCom to jointly handle heterogeneous classification and regression tasks on the complex Cityscapes dataset. We adopt the information maximization (InfoMax) principle so that it accommodates mixed discrete and continuous semantic variables. In particular, we benchmark the proposed framework against independent single-task training, a conventional task-agnostic digital transmission, and single-encoder multi-decoder SemCom. Additionally, we investigate the impact of CU capacity on joint task performance, providing design insights. Extensive evaluations demonstrate that CMT-SemCom significantly outperforms the benchmarks.

eess.SP

Cross-modal triage network: a multimodal deep learning framework for severity-based triage and visual explainability in chest radiographs

Purpose: Increased number of chest radiograph (CXR) scans create a triage bottleneck, queueing urgent examinations behind routine ones. Existing AI tools are predominantly unimodal binary classifiers lacking severity awareness, and multimodal systems are rarely benchmarked against expert radiologists. To this end, we developed a multimodal deep learning framework for joint severity triage, pathology detection, and native visual explanation. Approach: We propose the cross-modal triage network (CMTN), fusing a Swin Transformer V2 visual encoder with a PubMedBERT text encoder via gated cross-attention. The CMTN was trained on 34,639 image-text pairs (12,489 patients) from MIMIC-CXR-JPG, optimizing an ordinal focal loss for four-tier severity triage and binary cross-entropy for 14 pathologies. Beyond quantitative benchmarking, attention heatmaps were evaluated against a blinded expert radiologist in a two-phase clinical audit comparing model triage output to expert severity assessment (100 cases) and grading spatial-semantic concordance (116 heatmaps). Results: The CMTN achieved strong ordinal agreement with reference labels (quadratic weighted kappa [QWK] = 0.9341, 95\% CI: 0.9219 to 0.9449) and macro-AUROC of 0.9970 across 14 pathologies, with 34~ms latency, outperforming the state-of-the-art BioViL multimodal baseline (QWK = 0.7679). However, the blinded Phase I clinical audit revealed substantially lower agreement with genuine radiologist judgment (QWK = 0.1399). Phase II found 54.3\% of heatmaps achieved clinically acceptable spatial localization. Conclusions: The CMTN demonstrated an efficient multimodal architecture for CXR triage. The divergence between algorithmic and radiologist agreement demonstrates that benchmark performance against NLP-derived labels is insufficient, highlighting the need for radiologist-labeled ground truth before clinical deployment.

eess.IV

Ultrasound-Based Prediction of Cirrhosis Decompensation Using Large-Scale Computer Vision Models

Decompensation represents a critical transition in the course of cirrhosis, yet clinicians have limited non-invasive tools to reliably predict its onset. In this study, we propose a novel imaging-based approach that leverages large-scale computer vision models to analyze routine abdominal ultrasound images and extract predictive features beyond those captured by traditional laboratory-based risk scores. Ultrasound is widely available, low cost, and suitable for longitudinal surveillance, making it an attractive modality for scalable risk stratification and long-term follow-up. Our framework integrates automated ultrasound data processing with modern deep learning architectures to identify patients at high risk of decompensation prior to the occurrence of clinical deterioration. This non-invasive strategy offers a practical complement to existing clinical scoring systems and may enable earlier, more proactive management of patients with compensated cirrhosis.

eess.IV

Development and Evaluation of Ultrasound Image Learning Pipelines for MASLD Risk Stratification

Metabolic dysfunction-associated steatotic liver disease (MASLD) affects approximately 30% of the general population. Ultrasound-based imaging, including B-mode imaging and shear wave elastography (SWE), is widely used for noninvasive fibrosis assessment; however, the role of deep learning-based ultrasound image learning for MASLD risk stratification remains insufficiently characterized. In this study, we developed and evaluated ultrasound image learning pipelines using B-mode and SWE images for fibrosis staging and identification of patients with at-risk metabolic dysfunction-associated steatohepatitis (MASH). A total of 250 ultrasound examinations, one exam per subject, were included. Model performance was evaluated using 3-fold cross-validation with area under the receiver operating characteristic curve (AUROC). End-to-end SWE image learning achieved performance comparable to operator-guided SWE across fibrosis stages. Overall, SWE-based learning consistently outperformed B-mode image learning in fibrosis staging, with AUROC improvements from 0.64 (95%CI: [0.56, 0.72]) to 0.72 (95% CI: [0.65, 0.79]) for F>=2 (significant fibrosis, p=0.11), from 0.67 (95%CI: [0.58, 0.75]) to 0.78 (95% CI:[0.72, 0.85]) for F>=3 (advanced fibrosis, p=0.02), and from 0.69 (95%CI: [0.56, 0.82]) to 0.80 (95%CI: [0.72, 0.89]) for F4 (cirrhosis, p=0.10). These findings highlight the potential of SWE image learning for MASLD risk stratification.

eess.IV

Fractional-Order Adaptive Motion Magnification: Phase-Reliability Weighting for Noise-Constrained Video Amplification

Eulerian video amplification boosts sub-pixel motion by band-pass filtering per-pixel intensity traces and applying a uniform gain. That gain ignores local structure, so sensor noise is amplified together with the signal, especially in textureless regions where the monogenic phase is unreliable. We propose FrAM (Fractional-order Adaptive Motion Magnification), a pipeline developed first offline and then as a causal stream. It replaces the constant temporal gain with a Grünwald--Letnikov derivative of fractional order, giving continuous control over high-frequency emphasis, and replaces the uniform spatial gain with a per-pixel weight derived from the local amplitude of the monogenic signal. On a controlled synthetic sequence split into textured and flat halves, FrAM matches the amplification of the Eulerian baseline while keeping flat-region temporal noise at the input level. The reduction holds across an eightfold range of input noise levels. Real videos show improved spatial selectivity and lower background noise in every case. The causal reformulation cuts the per-frame cost by two orders of magnitude, reaching 69\,fps at 640$\times$480.

eess.IV

Explainable Multimodal Deep Learning Integrating Imaging and Clinical Data for Oral Potentially Malignant Disorder Detection

Oral potentially malignant disorders (OPMDs) are critical precursors to oral cancer, yet clinical detection remains challenging because of substantial phenotypic heterogeneity and overlap with benign conditions. Although image-based deep learning shows promise for automated screening, visual information alone may be insufficient in real-world settings, where diagnostic decisions also rely on patient-specific risk factors. We developed M2-OPMDNet, a multimodal deep learning framework that integrates co-registered white-light and autofluorescence intraoral images with structured clinical information for OPMD detection. A customized questionnaire was designed to capture clinically relevant risk factors and symptoms in a standardized, reproducible format for integration with image-derived features. Multiple image encoders, including conventional convolutional neural networks and foundation model-based architectures, were evaluated using a prospectively collected dataset reflecting real-world screening conditions. Model interpretability was assessed using SHapley Additive exPlanations (SHAP) to quantify feature- and modality-level contributions. M2-OPMDNet achieved an AUC of 0.952, outperforming unimodal approaches and showing improved performance for visually subtle lesions. SHAP analysis demonstrated that structured clinical variables contributed substantially to risk estimation and complemented imaging features. These results demonstrate that explainable multimodal learning combining white-light and autofluorescence imaging with structured clinical data can provide accurate, transparent, and clinically grounded OPMD detection. M2-OPMDNet offers a scalable framework for real-world oral cancer screening and decision support.

eess.IV

Decoupled Data Consistency with Diffusion Purification for Image Restoration

Diffusion models have recently gained traction as a powerful class of deep generative priors, excelling in a wide range of image restoration tasks due to their exceptional ability to model data distributions. To solve image restoration problems, many existing techniques achieve data consistency by incorporating additional likelihood gradient steps into the reverse sampling process of diffusion models. However, the additional gradient steps pose a challenge for real-world practical applications as they incur a large computational overhead, thereby increasing inference time. They also present additional difficulties when using accelerated diffusion model samplers, as the number of data consistency steps is limited by the number of reverse sampling steps. In this work, we propose a novel diffusion-based image restoration solver that addresses these issues by decoupling the reverse process from the data consistency steps. Our method involves alternating between a reconstruction phase to maintain data consistency and a refinement phase that enforces the prior via diffusion purification. Our approach demonstrates versatility, making it highly adaptable for efficient problem-solving in latent space. Additionally, it reduces the necessity for numerous sampling steps through the integration of consistency models. The efficacy of our approach is validated through comprehensive experiments across various image restoration tasks, including image denoising, deblurring, inpainting, and super-resolution.

eess.IV

Adversarial Stress Testing of Outlier Detection in Subjective Image Quality Assessment

In subjective image and video quality assessment, observers rate or compare selected stimuli. Before calculating mean opinion scores (MOSs), unreliable ratings should be identified and handled as outliers. Several outlier-detection methods are available, including standardized procedures, but their comparative performance is often evaluated using only specific types of synthetic outliers such as random clickers. Such tests do not necessarily reveal the worst-case behavior of these methods. To address this gap, we introduce and demonstrate a general empirical worst-case framework for outlier-detection methods, with proof-of-concept adversarial attack generators for both discrete absolute category and continuous visual analog scale ratings. The attacks use optimization algorithms to identify ratings that maximize the discrepancy between the resulting MOS estimates and the ground truth. We apply the proposed framework to several hard and soft outlier-detection methods and demonstrate substantial differences in their worst-case reconstruction performance under adversarial stress. We also propose several low-complexity outlier-detection methods that achieve excellent empirical worst-case performance.

eess.IV

Secure AI-Driven Super-Resolution for Real-Time Mixed Reality Applications

Immersive formats such as 360° and 6DoF point cloud videos require high bandwidth and low latency, posing challenges for real-time AR/VR streaming. This work focuses on reducing bandwidth consumption and encryption/decryption delay, two key contributors to overall latency. We design a system that downsamples point cloud content at the origin server and applies partial encryption. At the client, the content is decrypted and upscaled using an ML-based super-resolution model. Our evaluation demonstrates a nearly linear reduction in bandwidth/latency, and encryption/decryption overhead with lower downsampling resolutions, while the super-resolution model effectively reconstructs the original full-resolution point clouds with minimal error and modest inference time.

cs.CR

AtlasPatch: Scalable Foundation Model-based Tissue Detection and Patch Extraction for Computational Pathology

Whole-slide image (WSI) preprocessing, including tissue detection and patch extraction, is critical computational pathology, yet remains a major bottleneck for large-scale workflows. Existing methods often rely either on threshold-based heuristics that are sensitive to staining variations, tissue fragmentation, and artifacts, or on patch-wise deep learning pipelines with substantially higher computational cost. We present AtlasPatch, a scalable high-throughput WSI preprocessing method built around a foundation-model-based tissue detector that operates at thumbnail resolution: a single thumbnail-level forward pass yields a tissue mask that directly guides patch coordinate generation at the target desired magnification, avoiding repeated patch-level inference. The proposed detector's robustness and efficiency is driven by two coupled contributions: (i) a parameter-efficient adaptation of the SAM2 foundation model that updates only its layer-normalization parameters (0.076% of model weights), and (ii) a curated and semi-manually annotated multi-cohort dataset of 30,000 WSI thumbnail-mask pairs deliberately spanning multiple organs, scanners, tissue appearances, and artifacts. The detector is coupled with pyramid-aware contour mapping from thumbnail to full-resolution slide coordinates, enabling direct patch coordinate generation at the target magnification and parallelized high-throughput patch extraction. AtlasPatch's tissue detection achieves a precision of 0.986 and remains robust across slide variations. Compared with widely used deep-learning preprocessing methods, AtlasPatch is up to 16x faster while preserving downstream multiple-instance learning performance across six slide-level classification tasks. These results position AtlasPatch as a frontier of efficient preprocessing in large-scale computational pathology and pathology foundation models.

eess.IV

VideoPulse: Neonatal heart rate and peripheral capillary oxygen saturation (SpO2) estimation from contact free video

Remote photoplethysmography (rPPG) enables contact free monitoring of vital signs and is especially valuable for neonates, since conventional methods often require sustained skin contact with adhesive probes that can irritate fragile skin and increase infection control burden. We present VideoPulse, a neonatal dataset and an end to end pipeline that estimates neonatal heart rate and peripheral capillary oxygen saturation (SpO2) from facial video. VideoPulse contains 157 recordings totaling 2.6 hours from 52 neonates with diverse face orientations. Our pipeline performs face alignment and artifact aware supervision using denoised pulse oximeter signals, then applies 3D CNN backbones for heart rate and SpO2 regression with label distribution smoothing and weighted regression for SpO2. Predictions are produced in 2 second windows. On the NBHR neonatal dataset, we obtain heart rate MAE 2.97 bpm using 2 second windows (2.80 bpm at 6 second windows) and SpO2 MAE 1.69 percent. Under cross dataset evaluation, the NBHR trained heart rate model attains 5.34 bpm MAE on VideoPulse, and fine tuning an NBHR pretrained SpO2 model on VideoPulse yields MAE 1.68 percent. These results indicate that short unaligned neonatal video segments can support accurate heart rate and SpO2 estimation, enabling low cost non invasive monitoring in neonatal intensive care.

eess.IV

FlatLands: Generative Floormap Completion From a Single Egocentric View

A single egocentric image typically captures only a small portion of the floor, yet a complete metric traversability map of the surroundings would better serve applications such as indoor navigation. We introduce FlatLands, a dataset and benchmark for single-view bird's-eye view (BEV) floor completion. The dataset contains 270,575 observations from 17,656 real metric indoor scenes drawn from six existing datasets, with aligned observation, visibility, validity, and ground-truth BEV maps, and the benchmark includes both in- and out-of-distribution evaluation protocols. We compare training-free approaches, deterministic models, ensembles, and stochastic generative models. Finally, we instantiate the task as an end-to-end monocular RGB-to-floormaps pipeline. FlatLands provides a rigorous testbed for uncertainty-aware indoor mapping and generative completion for embodied navigation.

cs.CV

Data-Efficient Networks for Multi-Contrast MRI Reconstruction based on a Generalized Content/Style Prior

Multi-contrast MR scans contain redundant structural information that can be leveraged during reconstruction and potentially accelerate acquisition times. This idea has inspired end-to-end guided reconstruction models, leveraging one or more contrasts to guide the reconstruction of a different contrast. However, these models require large paired multi-contrast raw datasets for training, limiting their application in low-data regimes. In this work, we propose a modular framework, namely CoSMo-RecNet, for learning guided reconstruction models in the low-data regime. At its core is a reusable multi-contrast representation based on a content/style model, which can be learned from large-scale, publicly accessible, unpaired multi-contrast image datasets, without available k-space data. Using this frozen model as a multi-contrast prior and using a set of reference contrasts, the reconstruction problem reduces to a much simpler refinement problem that can be solved by a lightweight unrolled network and thus learned from small, task-specific reconstruction datasets. We demonstrate the efficacy of CoSMo-RecNet by evaluating it on the low-field 0.3 T M4Raw dataset, showing stable reconstruction quality on decreasing the raw training data budget. CoSMo-RecNet achieved higher reconstruction quality with 5 training subjects or lower compared to a parameter-count-matched MoDL trained on 100 subjects. On a data-limited and severely out-of-distribution ultra-low-field 47 mT Halbach scanner dataset, CoSMo-RecNet was superior to other viable strategies, including classical reconstruction, transfer learning, and zero-shot reconstruction.

eess.IV

Perceptually Regularized Diffusion Model for Image Super-Resolution

Image super-resolution, which aims to reconstruct high-resolution images from their low-resolution observations, is fundamental to medical imaging, remote sensing, surveillance, microscopy, and scientific visualization. Traditional model-based methods formulate super-resolution as an inverse problem with hand-crafted regularization priors. While interpretable and theoretically grounded, they rely on fixed assumptions and require computationally intensive iterative solvers. Deep learning methods offer data-driven flexibility by learning nonlinear mappings from low- to high-resolution images, among which diffusion models have achieved particularly impressive perceptual quality. However, the standard diffusion training objective is a pixel-domain noise-prediction loss that does not explicitly enforce perceptual fidelity, which can lead to oversmoothing and loss of fine image structure. To address these limitations, we propose a perceptually regularized diffusion framework that incorporates prior knowledge through perceptual-loss-based regularization, improving training convergence and encouraging the recovery of meaningful image features. Experiments on benchmark datasets demonstrate improved perceptual quality and competitive distortion metrics, highlighting the effectiveness of regularization for diffusion-based super resolution.

eess.IV

Seeing Beyond the Lesion: Disease Recognition from Reactive CNS Tissue

Sampling error yields exclusively reactive, non-lesional brain parenchyma in a significant proportion of intracranial biopsies, leaving the underlying disease undiagnosed. We benchmark four pathology foundation models (UNI2-h, Virchow2, Prov-GigaPath, H-optimus-0) as frozen patch encoders within a shared attention-based multiple-instance learning framework using 245 whole-slide images from 186 patients with confirmed downstream diagnoses. We first show that coarse disease-category prediction can be reproduced largely from slide size alone. After restricting classification to three finer diagnostic distinctions within common tissue categories, this confound no longer explains performance, yet disease labels remain predictable above chance under permutation testing (p $\le 10^{-4}$ throughout). Surprisingly, performance is statistically indistinguishable across all foundation-model encoders, suggesting that recovering these weak morphological signatures is not limited by current patch representations. Signed instance-contribution maps and expert review further test whether predictive evidence localizes to reactive parenchyma rather than sampling-induced bias like blood introduced during tissue sampling. These results position acquisition-shortcut auditing via a provenance-only baseline as a necessary control in computational-pathology benchmarks, and show, once that confound is removed, that weakly supervised models still recover disease signal from tissue conventionally regarded as non-diagnostic.

eess.IV

LightBridge: Feed-Forward Generative Relighting for 3D Gaussian Splatting

3D Gaussian Splatting (3DGS) achieves high-quality, real-time novel view synthesis, but the resulting assets have baked-in illumination and cannot be easily relit. Inverse rendering methods optimize simplified reflectance and illumination models for each scene, limiting efficiency and relighting quality. Recent generative approaches leverage large diffusion models for realistic lighting edits, but applying them to 3DGS typically requires an additional per-scene optimization stage to bake the edited appearance into the representation. We present LightBridge, a feed-forward generative framework for controllable relighting of complete 3DGS assets in a single pass. To enable feed-forward training, we construct a large-scale Multi-Illumination Relighting Dataset with paired source and target observations of the same scenes. Latent Bridge Relighting Diffusion models relighting as source-to-target transport in latent space, enabling one-step extraction of 2D visual tokens without iterative diffusion sampling. A Gaussian Propagation Transformer uses a point transformer with sparse image-to-point self-attention followed by point-to-image cross-attention to efficiently propagate these cues across the complete 3DGS, while avoiding full attention over all image and Gaussian tokens. Experiments validate these designs, demonstrating competitive relighting quality and efficient single-pass prediction of complete relit 3DGS assets without scene-specific optimization. The code and dataset will be made publicly available upon acceptance.

cs.GR

LoFi RADIO: A Distilled In-Domain Backbone Applied for Artifact-Severity Grading of Ultra-Low-Field Neonatal Brain MR

Ultra-low-field MRI makes neonatal brain imaging deploy- able in low-resource settings, but its low SNR, lack of shielding, and long scan duration make it especially prone to acquisition artifacts, motivating automated quality control. We address the LISA 2026 Task 1a challenge: multi-label severity grading (0/1/2) of seven common image artifacts on ULF T2 weighted volumes. We identify that a number of backbones may be successfully paired with a classification MLP, but that no single backbone is uniformly best across artifacts. To improve performance, we evaluate routing complementary foundation model teachers through a per-artifact gate, as well as distilling the teachers into a single in-domain ViT-S student (LoFi RADIO) over an unlabeled low-field MRI corpus. Both of these strategies improve the weighted composite. The distilled backbone matches or exceeds the gate and has the added advantage of not requiring deployment of multiple large foundation models at infer- ence.

eess.IV