arXiv ScienceSearch

subject

eess.IV

eess.IV: explore 53 source-linked works published from 2022 to 2026, with original documents and citations.

This collection is a preview while coverage and quality are evaluated.

Search within this collection

Coverage and selection

Includes records with this source-supplied label or an explicit phrase match in their metadata. Matches indicate a mention, not proof that a paper uses a method or tests a material. Source versions are consolidated by DOI.

Sources: arxiv. Collection updated 2026-09-15. Counts describe this index, not the complete source archives.

From crown candidates to neighborhood screening: integrating optical GeoAI and spatial modeling for urban-canopy assessment in Davis, California

Timely urban-canopy information is essential for linking remote sensing with heat, mobility, and neighborhood planning. We developed an optical GeoAI workflow for Davis, California, using 2022 National Agriculture Imagery Program imagery (0.6 m RGB+NIR). DeepForest generated crown candidates; an NDVI threshold, non-maximum suppression, and box-prompted Segment Anything Model (ViT-B) produced a crown-anchored canopy surface. Analyses used the 25.92 km2 Census TIGER municipal boundary and a 100 m grid. The workflow retained 11,741 candidate crowns and mapped 7.71 km2 of canopy (29.8% of the city). On the identical extent, pixel precision was 0.804, pixel recall was 0.873, and 97.4% of candidate centers agreed with the 2022 USDA/CAL FIRE LiDAR-assisted canopy product (IoU 0.719; Dice 0.837; area recovery 108.5%). Approximately 49% of candidates occurred within 15 m of a road. Canopy was inversely associated with Landsat land-surface temperature (Spearman rho = -0.477; partial rho = -0.551 controlling for built probability), and spatial-lag modeling confirmed clear neighborhood structure. Two transparent attention surfaces combined canopy need with thermal and contextual indicators. The framework provides a reproducible, updateable screening layer that complements structural canopy products and municipal inventories while retaining assumptions, data provenance, and spatial diagnostics for planning interpretation.

eess.IV

ReLViC: Loss-Resilient Learned Video Coding with Dispersed Packetization and Controllable Packet Dependencies

Packet loss can severely impair learned video coding because missing latent tokens compromise both spatial reconstruction and temporal prediction. We present ReLViC, a loss-resilient learned video coding framework that jointly addresses latent coding and packet-loss recovery. ReLViC disperses spatially adjacent latent tokens across packets and employs a dual-purpose Transformer to estimate entropy-model parameters during coding and reconstruct missing latent tokens at the receiver. It controls packet dependencies through a periodic-reset packet-context topology parameterized by the segment length, thereby tuning the trade-off between compression efficiency and error-propagation range without retraining. A three-stage progressive training procedure establishes single-frame coding, learns temporal context for entropy modeling, and then optimizes the recovery of masked latent tokens under simulated packet loss. Experiments using burst-loss traces evaluate ReLViC against H.265 protected by Reed--Solomon forward error correction (FEC) and GRACE, a loss-resilient learned video codec. ReLViC delivers more stable reconstruction and outperforms both baselines under severe packet loss.

eess.IV

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

cs.CV

Real-Time Video Anomaly Detection Using YOLO Pose Estimation and CLIP-Based Semantic Scoring

We propose a lightweight two-stage framework for real-time video anomaly detection. The first stage employs YOLO v11n-pose to detect persons and extract seventeen skeletal keypoints in a single forward pass. The second stage encodes each cropped person region through CLIP ViT-B/32 and computes cosine similarity against predefined textual descriptions of anomalous behaviors. This architecture eliminates the need for optical flow, standalone pose estimators, and density-based scoring modules. Experiments on CUHK Avenue, ShanghaiTech Campus, and a custom indoor dataset collected at Chulalongkorn University demonstrate an end-to-end throughput of approximately 51 FPS on an NVIDIA Titan XP GPU, a 3.36x speedup over the multi-feature baseline, while maintaining frame-level AUROC values of 89.26%, 70.26%, and 84.13%, respectively.

cs.CV

Expert-like Bone Ultrasound Segmentation through Expert-in-the-loop Mask-conditioned Progressive Learning

Manual annotation remains a major bottleneck in ultrasound (US) bone segmentation, where experts typically iteratively refine rough brush masks rather than delineating precise contours in a single pass. We present ExiL, a mask-conditioned progressive learning framework that models annotation as a structured refinement trajectory. ExiL combines a synthetic expert-like brush simulator based on signed distance fields with a lightweight 7.8M-parameter U-Net that learns to complete and refine imperfect masks from US images. During deployment, an expert mode updates the model directly from accepted refinements, enabling continual adaptation to expert behavior. Evaluated using UltraBones100k cadaver data for quantitative segmentation and a prospective volunteer dataset for annotation-efficiency analysis, ExiL reduced single-expert average annotation time from 60 to 20 seconds per frame (66.7\%) and improved mean Dice by approximately 0.045 over non-progressive training, while achieving 0.87 Dice and 2.7 px boundary error in the best trajectory-aware setting. With 10--50 ms inference, ExiL enables real-time, self-improving annotation for US-guided orthopedic workflows in practical clinical labeling.

eess.IV

FracEvent: Event-Camera Simulation via Fractional-Relaxation Pixel Dynamics

Event cameras asynchronously report brightness changes with microsecond-level temporal resolution, but real event data remain difficult to collect at scale because specialized sensors, careful synchronization, and task-specific annotations are required. Event-camera simulation is therefore important to event-based vision tasks. Most practical simulators build on contrast-threshold event generation, some with additional filtering, stochastic noise, or hand-tuned sensor parameters. While effective, such formulations often simplify the temporal structure produced by the lifecycle of each pixel, which can distort event timing and weaken downstream transfer. We introduce FracEvent, an event simulator that models this pixel-level lifecycle with fractional-relaxation voltage dynamics. Given a log-intensity trajectory, FracEvent drives a compact stack of relaxation modes, combines their responses into a voltage state, emits ON/OFF events by localizing threshold crossings on the continuous voltage trajectory, and updates the reference while retaining the underlying memory modes. This retained state links residual voltage response to later event timing. We evaluate FracEvent through event-stream comparison and downstream transfer on image reconstruction and optical flow estimation. Across multiple datasets, FracEvent improves the temporal structure of generated events and achieves stronger downstream-transfer results than competing simulator baselines, showing its practical value for event-camera simulation.

cs.CV

Fast Trainable Multilinear Bases for Image Compression

The Discrete Fourier Transform (DFT), the Discrete Cosine Transform (DCT), and their block-wise variants underpin most deployed image and video codecs. Their effectiveness rests on three properties: their runtime is near-linear (up to a polylogarithmic factor) in the image size, they are exactly invertible, and they carry few to no parameters. In this work, we generalize these bases to isometric multilinear bases, allowing a small number of extra parameters (polylogarithmic in the image size), while preserving all three properties. We develop a scheme to train a better transformation for a given image dataset: we use isometric tensor networks, inspired by quantum many-body theory, to parameterize the basis, and train it with Riemannian optimization. We show that training consistently improves performance, as our parameterized bases can represent the traditional DFT and DCT-IV (a variant of the DCT). Evidence is shown across natural photographs and line drawings. On Quick Draw line-drawing compression, for example, the best trained basis outperforms the block cosine transform used in the JPEG format by $20\%$ in terms of compressed data size.

eess.IV

Feature-Spectral Fragility in Segmentation: Dataset Dependence, Architecture-Specific Localization, and Spectral Correlates

Robustness of segmentation models is commonly assessed through input-domain perturbations, while dependence on frequency content within learned feature representations remains less understood. We probe this dependence using targeted post-training low-pass interventions on internal representations of three segmentation architectures, ResNet50-UNet (CNN), VM-UNet (SSM), and Swin-UNETR (Transformer), across CVC-ClinicDB and ISIC2018, with headline evaluations performed on untouched held-out test sets. At cutoff rho=0.25, feature-domain low-pass filtering causes severe degradation on CVC: Dice drops by 100%, 73.2%, and 30.9% for CNN, SSM, and Transformer, respectively, compared with 9.4%, 10.3%, and 0.6% on ISIC. The cross-dataset difference is statistically significant for every architecture. Single-stage interventions further show that sensitivity is localized at architecture-specific depths: the CNN peaks at a mid/late encoder block, whereas the SSM peaks in an early encoder stage on both datasets. Native feature-domain spectral measurements show an inverse association between high-frequency energy and fragility on CVC; the relationship is only partial on ISIC and is therefore treated as a candidate correlate rather than a proven mechanism. Finally, Fourier augmentation improves robustness to input-space low-pass filtering but leaves feature-domain degradation essentially unchanged. These results show that feature-spectral robustness is strongly dataset-dependent, architecture-specific, and distinct from input-domain spectral robustness.

cs.CV

Bayesian-Optimized Superpixel-GrabCut for Traceable Optic Disc Segmentation

Optic disc (OD) segmentation is essential for diagnosing ophthalmic pathologies from retinal fundus images. However, prevailing deep learning approaches operate as opaque black boxes, lacking the inference-stage mathematical traceability--a critical requirement for algorithmic auditing and failure analysis in clinical workflows. This paper presents a fully algorithmically traceable and trainable segmentation pipeline that jointly combines superpixel decomposition, hybrid brightness-proximity superpixel scoring, morphological regularization, iterative GrabCut refinement, and elliptical shape fitting. The hyperparameter optimization is formulated as an objective function and solved via Bayesian optimization to eliminate manual parameter tuning. A quantitative evaluation on the Drishti-GS dataset demonstrates that our method achieves a Dice coefficient of 0.9536, matching state-of-the-art performance. By maintaining explicit mathematical transparency across all processing stages, our framework offers a deterministic, traceable alternative to black-box architectures for medical review and debugging.

cs.CV

The MYOSAIQ Challenge: Myocardial Segmentation with Automated Infarct Quantification

Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Nowadays MI volume quantification is not performed routinely in clinical practice. Numerous deep learning (DL) methods have been developed to automate the segmentation of the myocardium and infarct regions. However, most studies rely on relatively small datasets which typically undergo pre-processing steps to standardize images and focus on a specific phase of myocardial infarction following reperfusion therapy. These limitations have impeded the development of models that are generalizable across diverse conditions and thus suitable for routine clinical use. To advance research and establish benchmarks in generalizable learning for myocardial infarct quantification, this paper presents findings from the Myocardial Segmentation with Automated Infarct Quantification (MYOSAIQ) challenge. The dataset set up for the challenge combines 439 CMR volumes from two multicenter clinical trials, with representative data acquired in acute and chronic phases after acute MI. Data were acquired in 16 centers using MRI scanners from three different vendors. Six teams participated until the end of the challenge, employing various baseline models, data augmentation techniques, and confidence strategies. To enhance the significance of this study, we compare the challengers' results with those of fine-tuned foundation models. Our results indicate that well-designed UNet-based techniques outperform fully automatic foundation models for LGE MR segmentation. While the best methods achieve high-quality and stable delineations of the left ventricle and myocardium under various conditions, they remain improvable in accurately segmenting infarct regions.

eess.IV

Mixture of Multicenter Experts in Multimodal AI for Debiased Radiotherapy Target Delineation

Clinical decision-making reflects diverse strategies shaped by regional patient populations and institutional protocols. However, most existing medical artificial intelligence (AI) models are trained on highly prevalent data patterns, which reinforces biases and fails to capture the breadth of clinical expertise. Inspired by the recent advances in Mixture of Experts (MoE), we propose a Mixture of Multicenter Experts (MoME) framework to address AI bias in the medical domain without requiring data sharing across institutions. MoME integrates specialized expertise from diverse clinical strategies to enhance model generalizability and adaptability across medical centers. We validate this framework using a multimodal target volume delineation model for prostate cancer radiotherapy. With few-shot training that combines imaging and clinical notes from each center, the model outperformed baselines, particularly in settings with high inter-center variability or limited data availability. Furthermore, MoME enables model customization to local clinical preferences without cross-institutional data exchange, making it especially suitable for resource-constrained settings while promoting broadly generalizable medical AI.

eess.IV

MRpro: open framework for model-based, learned, and quantitative MR imaging

We preseent an open-source image reconstruction package built upon PyTorch, enabling modern deep-learning reconstructions. It uses open data formats for input and output (ISMRMRD, DICOM, NIfTI), allowing easy integration into existing pipelines and support for data from different devices. The framework comprises three main areas. First, it provides unified data structures for the consistent manipulation of MR datasets and their associated metadata (e.g., k-space trajectories). Second, it offers a library of composable operators, proximable functionals, and optimization algorithms, including a unified Fourier operator for all common trajectories and operators specifically developed for low-field applications, such as a B0-correction operator. These components are used to create ready-to-use implementations of key reconstruction algorithms. Third, for deep learning, MRpro includes essential building blocks such as data-consistency layers, differentiable optimization layers, state-of-the-art backbone networks, and access to public datasets to facilitate reproducibility. We demonstrate MRpro across automatic reconstruction, iterative SENSE, deep-learning-based reconstruction, and quantitative parameter estimation. Applications use public and simulated datasets and measured lowfield data acquired at 0.3 T, 0.6 T, and 47 mT.

eess.IV

Ada-TokenCom: Rate-Adaptive Token Communications via Large-Model-Driven Token Compression and Generation

Token Communications (TokenCom) has recently emerged as a new paradigm in which tokens serve as unified units for communication and computation, enabling efficient multimodal semantic and goal-oriented transmission. In this paper, we develop Ada-TokenCom, a rate-adaptive TokenCom framework based on large autoregressive models, which integrates next-token prediction with arithmetic coding to achieve ultra-low bitrate semantic communication at the token level. We propose a mixed reconstruction/generation scheme, where the transmitter encodes and transmits the highly informative tokens at the beginning of the token sequence leveraging a pre-trained autoregressive large model, while the receiver uses an identical model to predict the rest. Moreover, we design a Lyapunov-based algorithm to dynamically optimize both the source compression rate and the modulation and coding scheme, adapting to time-varying network conditions. Simulation results demonstrate that our proposed Ada-TokenCom framework outperforms both digital and deep joint source-channel coding-based semantic communication baselines.

cs.IT

Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations

Interpreting a CT scan means comparing structures on either side, judging how far apart organs sit, and knowing where each one belongs. Medical vision encoders are evaluated on diagnostic accuracy, or through assembled multimodal systems where a failure is hard to attribute, so it remains unclear whether their representations support any of this. We construct SPAR-Bench, eight probes over multi-organ abdominal CT that separate coordinate localization, relational reasoning, and spatial queries, and apply them to five architectural configurations and three medical foundation models, frozen and finetuned. Probes that ask for a comparison within the slice stay at chance, and neither pretraining scale, finetuning, nor architecture closes the gap. Probes that appear solved in domain fall to chance under zero-shot transfer, indicating that their accuracy reflects recall of canonical anatomy rather than computation over the image. Reading the same frozen features with a pooled head rather than the full set of tokens moves relational recovery from 0.7% to 67.8%, so pooled probing understates what a representation holds. Questions the encoders answer well are answered at chance by four open-weight MLLMs. Our results suggest these encoders carry a map of where organs usually lie, and little of the machinery for comparing structures within a particular patient. Code and data will be available at https://spar-bench.github.io.

eess.IV

CheXtriev: Anatomy-Centered Representation for Case-Based Retrieval of Chest Radiographs

We present CheXtriev, a graph-based, anatomy-aware framework for chest radiograph retrieval. Unlike prior methods focussed on global features, our method leverages graph transformers to extract informative features from specific anatomical regions. Furthermore, it captures spatial context and the interplay between anatomical location and findings. This contextualization, grounded in evidence-based anatomy, results in a richer anatomy-aware representation and leads to more accurate, effective and efficient retrieval, particularly for less prevalent findings. CheXtriv outperforms state-of-the-art global and local approaches by 18% to 26% in retrieval accuracy and 11% to 23% in ranking quality. The code is available at https://github.com/cvit-mip/chextriev.

eess.IV

Lossy Event Compression: From Event Stream Distortion to Task Performance

Event cameras generate asynchronous, sparse data streams with microsecond temporal resolution, but in moderate-to-high motion scenes they can produce as many as hundreds of millions of events per second, creating significant bandwidth and storage challenges. Lossy compression is therefore essential for practical deployment, yet existing event stream distortion metrics fail to reliably predict compression-induced degradation at the task level, forcing codec optimization to rely on expensive task-specific evaluations. To address this gap, this paper introduces two fundamentally different event compression pipelines: i) an aggregation-based pipeline that converts the event stream into polarity-based histogram frames for compression with the conventional image codec JPEG 2000, and ii) a frame-free point cloud-based pipeline that codes events natively as 3D points using the octree-based codec G-PCC. Both pipelines are then assessed within a unified task-driven evaluation framework that relates event stream distortion to downstream application performance across four representative tasks: i) video reconstruction, ii) object detection, iii) optical flow estimation, and a delay-sensitive task iv) asynchronous feature tracking under a reference-relative protocol. Building on this framework, five classification-based distortion metrics are applied to event compression for the first time, to the best of the authors' knowledge, and benchmarked against existing event stream metrics. Experimental results demonstrate that the proposed metrics reliably predict compression-induced task degradation across different coding frameworks. This demonstrates that event stream distortion assessment can be an efficient alternative to repeated task-specific evaluation, providing direct guidance for the development and optimization of future event data coding solutions.

cs.CV

Coronary Mask Guided Registration for Continuous Time 4D Cardiac CT Dataset Construction

Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research. We aim to construct a 4D cardiac CT dataset that is generally suitable to serve as pseudo ground truth. Methods: We propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the ED or ES phase as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction. To capture the motion of both the RCA and other cardiac structures in each registration, CMGR regularizes RCA masks and incorporates them into image-domain registration. Time-continuity is achieved by interpolating the deformation fields for non-reference phases to arbitrary times. Results: CMGR outperformed representative image-domain registration methods in capturing RCA motion and providing reasonable RCA shape, and showed competitive performance in capturing whole-heart motion. Additionally, CMGR reduced motion artifacts from clinical multiphase reconstructions, and intermediate CMGR frames generally provided plausible transitions between discrete cardiac phases. Conclusion: CMGR provides an effective approach for constructing continuous-time 4D cardiac CT datasets. Significance: The dataset can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.

eess.IV

Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction

Objective: Deep learning accelerates brain MRI four- to tenfold, but models can erase lesions or synthesize false tissue - failures pixel-averaged metrics like PSNR and SSIM miss. We review whether current evaluation practices detect this blind spot. Methods: Following PRISMA 2020, we searched seven databases without date limits, including 263 studies (1995-2026), appraised them using QUADAS-2 and matched instruments, and synthesized narratively. Categories were derived from titles, abstracts, and controlled vocabulary; reported prevalence figures represent floors. Duplicate screening achieved high agreement (Fleiss kappa = 0.877), as did appraisal (0.788; 0.390 where observable). Extraction is unaudited. Results: Only 18 of 263 studies (6.8%) recorded both a fidelity metric and reader assessment on identical data, leaving the central surrogate unmeasured. Reader studies mostly measured inter-reader agreement, which was weak: fastMRI 2020 concordance reached 0.457 and 0.386 (Kendall W), improving only where SSIM diverged. Erasing a 100 mm3 lacunar infarct shifts global PSNR by 0.03 dB under the stated error model. As the corpus grew fivefold, reader assessments dropped from 32% to 18%, recovering to 21%. Generative models - most associated with hallucination (39%) - were among the least reader-evaluated (11.3%), while self-supervised models reached 47% with zero reader evaluation. Only 5% released code and ran reader studies; none evaluated a model observer; no named dataset covered acute stroke or hemorrhage. Conclusions: On these floors, current evaluation practices cannot certify diagnostic safety. We derive five requirements safety-oriented evaluations must meet.

eess.IV
Compare source metadata on this page
WorkPublishedSource identifierSource
From crown candidates to neighborhood screening: integrating optical GeoAI and spatial modeling for urban-canopy assessment in Davis, California2026-08-312608.13856arxiv
ReLViC: Loss-Resilient Learned Video Coding with Dispersed Packetization and Controllable Packet Dependencies2026-08-312608.30202arxiv
LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation2026-08-312608.31073arxiv
Real-Time Video Anomaly Detection Using YOLO Pose Estimation and CLIP-Based Semantic Scoring2026-08-312608.31074arxiv
Expert-like Bone Ultrasound Segmentation through Expert-in-the-loop Mask-conditioned Progressive Learning2026-08-312609.00473arxiv
FracEvent: Event-Camera Simulation via Fractional-Relaxation Pixel Dynamics2026-08-292606.26636arxiv
Fast Trainable Multilinear Bases for Image Compression2026-08-292608.00053arxiv
Feature-Spectral Fragility in Segmentation: Dataset Dependence, Architecture-Specific Localization, and Spectral Correlates2026-08-292608.29167arxiv
Bayesian-Optimized Superpixel-GrabCut for Traceable Optic Disc Segmentation2026-08-292608.29196arxiv
The MYOSAIQ Challenge: Myocardial Segmentation with Automated Infarct Quantification2026-08-292608.29246arxiv
Mixture of Multicenter Experts in Multimodal AI for Debiased Radiotherapy Target Delineation2026-08-282410.00046arxiv
MRpro: open framework for model-based, learned, and quantitative MR imaging2026-08-282507.23129arxiv
Ada-TokenCom: Rate-Adaptive Token Communications via Large-Model-Driven Token Compression and Generation2026-08-282608.28086arxiv
Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations2026-08-282608.28092arxiv
CheXtriev: Anatomy-Centered Representation for Case-Based Retrieval of Chest Radiographs2026-08-282608.28137arxiv
Lossy Event Compression: From Event Stream Distortion to Task Performance2026-08-282608.28429arxiv
Coronary Mask Guided Registration for Continuous Time 4D Cardiac CT Dataset Construction2026-08-282608.28712arxiv
Evaluating the Safety of Deep Learning-Based Brain MRI Reconstruction2026-08-282608.28714arxiv

These are bibliographic comparisons, not experimental rankings. Follow the original document for methods and conditions.