arXiv ScienceSearch

arXiv subjects

Z. Ge

Publications and source records attributed to Z. Ge.

At least 19 recordsLinked to original sources

Island of Inversion in neutron-rich cobalt isotopes revealed from mass measurements

Mass measurements of the ground and isomeric states of $^{68-70}$Co have been performed using the JYFLTRAP Penning-trap mass spectrometer at the IGISOL facility. The masses were measured, either for the first time for the isomeric states of $^{68}$Co and $^{70}$Co, or with greatly improved precision for the others, removing ambiguities in the mass surface beyond $N=40$. The ordering of the low and high-spin states in $^{68}$Co and $^{70}$Co has also been established. The results, supported by Large-Scale Shell Model and Discrete Non-Orthogonal Shell-Model calculations, show a gradual lowering of intruder states with increasing neutron number, eventually leading to an inversion in $^{70}$Co. These findings clarify previously proposed contradictory interpretations. Finally, we demonstrate the importance of including induced effective 3N forces for a consistent description of binding energies in the island of inversion near $N=40$.

nucl-ex

The dipole strength distribution of $^8$He and decay characteristics

The weak binding and spatially extended neutron densities characteristic of drip-line nuclei give rise to a distinctive low-energy dipole response. The drip-line nucleus $^8$He is the most neutron-rich bound nucleus with a mass-to-charge ratio of $A/Z=4$. We measure the dipole response of $^8$He, including for the first time the four-neutron decay channel. A total dipole strength of $\sum B(E1)(E^*<15$~MeV$)=0.95(16)~e^2$fm$^2$ and a dipole polarizability of $\alpha_D = 0.61(1)$~fm$^3$ are extracted from the differential Coulomb-excitation cross section and compared to state-of-the-art theoretical calculations employing coupled cluster and three-body approaches. We find that the dipole continuum is dominated, even at high excitation energies well above the $4n$ decay threshold, by two-neutron emission, pointing to a $^6$He$+2n$ structure of the excited dipole mode. No indication was found for a $4n$ final-state correlation, while pronounced $nn$ and $^6$He-$n$ final-state correlations are apparent.

nucl-ex

Direct observation of three-neutron emission from $^7$He$^*$ and the search for the trineutron

Three-neutron emission from $^7$He has been directly measured for the first time, following neutron knockout from a $^8$He beam at 156 MeV/nucleon. A resonance-like structure at $2.08(4)$ MeV above the $^4$He+$3n$ threshold [$E_x=2.68(4)$ MeV] with a width of $3.9(2)$ MeV was observed and deduced to arise predominately from the predicted $J^{\pi}=3/2^{-}_2$ level. The three-neutron invariant-mass spectrum was reconstructed and found to peak at around 1 MeV and could, through complete simulations incorporating neutron-neutron correlations, be very well described by the sequential decay of $^7$He$^*$ via the $2_1^+$ excited state of $^6$He. No evidence was found for any significant three-neutron correlations beyond those expected from well-established two-body interactions, including a trineutron resonance.

nucl-ex

Beam-test evaluation of pre-production Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS experiment as part of the Phase-II upgrade for the High Luminosity-Large Hadron Collider (HL-LHC). It will mitigate pile-up effects in the forward region, and measure per bunch luminosity. The design of HGTD is based on Low Gain Avalanche Detector (LGAD) sensors. This paper presents the results of beam-test campaigns conducted at CERN and DESY in 2023 and 2024 on single LGADs from HGTD pre-production test structures, before and after neutron irradiation up to fluences of $2.5 \times 10^{15}~\mathrm{n_{eq}/cm^2}$. The tested LGADs can meet HGTD requirements in terms of charge collection, time resolution, and hit efficiency, even under HL-LHC end-of-life conditions, supporting their deployment in the final detector.

physics.ins-det

Quenching factors for Na recoils as a function of Tl dopant concentrations in NaI(Tl) crystals

Thallium-doped sodium iodide (NaI(Tl)) scintillation detectors play an important role in the field of direct dark matter (DM) searches. The DAMA/LIBRA experiment stands out for its reported observation of an annually modulating DM-like signal, which is in direct contrast with other results. To accurately calibrate the energies of nuclear recoil signals with electron recoils, precise measurements of the quenching factor of the NaI(Tl) crystals are essential, as the two processes have different scintillation light yield. In this article, we present results of a systematic study carried out by the COSINUS collaboration and Duke University to measure the quenching factor of sodium (Na) recoils as a function of nuclear recoil energy and for differing Thallium (Tl) dopant concentrations in the bulk crystal. Five ultrapure NaI(Tl) crystals, manufactured by the Shanghai Institute for Ceramics, were irradiated with a quasi-monoenergetic neutron beam at the Triangle Universities Nuclear Laboratory, North Carolina, USA. The quenching factor for low nuclear recoil energies of 5-26keV$_{nr}$ was extracted for all 5 crystals. A Tl-dependence could be deduced with a proportional response calibration schema using a $^{241}$Am source. However, this effect was not observed when using a low-energy calibration line from $^{133}$Ba.

physics.ins-det

Thermal Cycling Reliability of Hybrid Pixel Sensor Modules for The ATLAS High Granularity Timing Detector

The reliability of bump connection structures has become a critical aspect of future silicon detectors for particle physics. The High Granularity Timing Detector (HGTD) for the ATLAS experiment at the High-Luminosity Large Hadron Collider will require 8032 hybrid pixel sensor modules, composed of two Low Gain Avalanche Diode sensors bump-bonded to two readout ASICs and glued to a passive PCB. The detector will operate at low temperature (-30 degrees Celsius) to mitigate the impact of irradiation. The thermomechanical reliability of flip-chip bump connections in HGTD modules is a critical concern, particularly due to their characteristically lower bump density (pixel pitch dimensions of 1.3 mm by 1.3 mm). This paper elaborates on the challenges arising from this design characteristic. Finite element analysis and experimental testing were employed to investigate failure modes in the flip-chip bump structures under thermal cycling from -45 degrees Celsius to 40 degrees Celsius and to guide the module redesign. The optimized design demonstrates significantly enhanced robustness and is projected to fulfill the full lifetime requirements of the HGTD.

physics.ins-det

High-resolution multi-reflection time-of-flight mass spectrometer for exotic nuclei at IGISOL

A Multi-Reflection Time-of-Flight Mass Spectrometer (MR-ToF-MS) has been commissioned at the Ion-Guide Isotope Separator On-Line (IGISOL) facility. It consists of six electrode pairs that form a nearly energy-isochronous potential and a pulsed drift-tube to trap the ions between the electrodes. Time-of-flight peak widths down to 22 ns full-width at half-maximum and mass-resolving powers of $\approx 1.5 \times 10^5$ within 20 ms have been demonstrated. The obtained time-focus and mass-resolving power depend sensitively on the trapping energy, energy spread and the number of revolutions of the ions. The mass-resolving power is affected by the temporal and energy spread of the ions entering the MR-ToF-MS, and fluctuations in the electrode voltages due to temperature variations. The longitudinal emittance corresponding to the temporal and energy spread of $^{39}$K is estimated to be 175 eVns based on the data, close to the expected 186(10) eVns. The time-of-flight temperature sensitivity is found to be -5.55(30) ppm/K. In addition to atomic mass measurements of short-lived exotic nuclides, the MR-ToF-MS can be used as a fast mass separator for various other experiments at IGISOL and as an ion counter for laser spectroscopy and yield measurements.

physics.ins-det

Probing the quantum phase transition around $N\approx60$ via mass measurements of technetium isotopes

The masses of neutron-rich $^{104-106}$Tc isotopes were measured using the JYFLTRAP double Penning trap and found to deviate from the Atomic Mass Evaluation 2020 by $-79(25)$, $40(12)$ and $94(41)$ keV, respectively. In the case of $^{105,106}$Tc, the updated $Q_\beta$ values are in agreement with a previous JYFLTRAP measurement, disagreeing with the values from the mass evaluation. The new mass values result in a more linear trend in two-neutron separation energies indicating that technetium ($Z=43$) isotopes around $N \approx 60$ are not a part of the island of shape coexistence around $^{100}$Zr$_{60}$.

nucl-ex

COSINUS model-independent sensitivity to the DAMA/LIBRA dark matter signal

COSINUS is a dark matter direct detection experiment using NaI crystals as cryogenic scintillating calorimeters. If no signal is observed, this will constrain the dark matter scattering rate in sodium iodide. We investigate how this constraint can be used to infer that the annual modulation signal observed in the DAMA/LIBRA experiment cannot originate from dark matter nuclear recoil events, independently of the dark matter model. We achieve this by unfolding the DAMA modulation spectrum to obtain the implied unquenched nuclear recoil spectrum, which we then compare to the expected COSINUS sensitivity. We find that assuming zero background in the signal region, a 1$\sigma$, 2$\sigma$ or 3$\sigma$ confidence limit exclusion can be obtained with 57, 130 or 250 kg day of exposure, respectively. A simple background model indicates that in the presence of background, the exposure requirements may increase by $\sim30\%$.

hep-ph

Performance of the MORA Apparatus for Testing Time-Reversal Invariance in Nuclear Beta Decay

The MORA experimental setup is designed to measure the triple-correlation D parameter in nuclear beta decay. The D coefficient is sensitive to possible violations of time-reversal invariance. The experimental configuration consists of a transparent Paul trap surrounded by a detection setup with alternating beta and recoil-ion detectors. The octagonal symmetry of the detection setup optimizes the sensitivity of positron-recoil-ion coincidence rates to the D correlation, while reducing systematic effects. MORA utilizes an innovative in-trap laser polarization technique. The design and performance of the ion trap, associated beamline elements, lasers and beta and recoil-ion detectors, are presented. Recent progress towards the polarization proof-of-principle is described.

physics.ins-det

Discovery of a new long-lived isomer in $^{114}$Rh via Penning-trap mass spectrometry

We report on mass measurements of three long-lived states in $^{114}$Rh performed with the JYFLTRAP Penning-trap mass spectrometer: the ground state and two isomers with estimated half-lives of about one second. The used Phase-Imaging Ion-Cyclotron-Resonance technique allowed for the discovery of a so far unknown second long-lived isomer. All three states were produced directly in proton-induced fission on a uranium target, whereas only the isomeric states were populated in the $\beta$ decay of the $^{114}$Ru ground state with spin-parity $0^+$. We propose spin-parity assignments of $(6^-)$ for the ground state, and $(3^+)$ and $(0^-)$ for the isomers. They resolve the puzzle of anomalous fission yields of this isotope despite the existing literature assigning a low angular momentum to the ground state. The experimental evidence is further supported by a detailed analysis based on mean-field calculations with the BSkG3 model. As for many other nuclei in this mass region, considering triaxial shapes is decisive for the interpretation of low-lying states of this nucleus. The discovery of a new isomer in $^{114}$Rh and our theoretical work challenge the currently adopted spin-parity assignments in this and several other odd-odd neutron-rich Rh isotopes.

nucl-ex

Ultra-low $Q_\beta$ value for the allowed decay of $^{110}$Ag$^m$ confirmed via mass measurements

The mass of the electron-antineutrino can be determined in dedicated measurements of the $\beta$ spectral shape near the $\beta$ endpoint of a $\beta^-$ transition, with a low $Q$ value enhancing the sensitivity of the measurement. One such low-$Q$-value candidate is the transition between the $6^+$ isomer of $^{110}$Ag and the $5^+_2$ state in $^{110}$Cd ($Q^{\ast}_{\beta,m}=-0.12(131)$ keV). To reduce the uncertainty of the $Q$ value, we have used the phase-imaging ion-cyclotron-resonance technique with the JYFLTRAP double Penning trap and performed a high-precision atomic-mass measurement of $^{109}$Ag with $^{110}$Cd as a reference. Combined with the known spectroscopic data, we obtain a re-evaluated value $Q^{\ast}_{\beta,m}=405(135)$ eV, for the $^{110}\text{Ag}(6^+_\text{m}) \rightarrow {^{110}\text{Cd}}(5^+_2)$ transition. This represents the lowest $Q_{\beta}$ value for any allowed transition observed to date. In order to estimate the partial half-life ($t_{1/2}$) and branching ratio (Br) of the transition, nuclear shell-model calculations were performed using the $jj45pnb$ Hamiltonian in combination with state-of-the-art atomic calculations. The computed values $t_{1/2} = 2.23^{+5.24}_{-1.28} \times 10^7$ years and $\textrm{Br} = 3.07^{+4.16}_{-2.15} \times 10^{-8}$, along with the thermal-neutron capture on stable $^{109}$Ag as a viable production method, make $^{110}\textrm{Ag}^m$ a promising candidate for future antineutrino-mass measurements.

nucl-ex

Neutrino flux sensitivity to the next galactic core-collapse supernova in COSINUS

While neutrinos are often treated as a background for many dark matter experiments, these particles offer a new avenue for physics: the detection of core-collapse supernovae. Supernovae are extremely energetic, violent and complex events that mark the death of massive stars. During their collapse stars emit a large number of neutrinos in a short burst. These neutrinos carry 99\% of the emitted energy which makes their detection fundamental in understanding supernovae. This paper illustrates how COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches), a sodium iodide (NaI) based dark matter search, will be sensitive to the next galactic core-collapse supernova. The experiment is composed of two separate detectors which will be sensitive to far and nearby supernovae. The inner core of the experiment will consist of NaI crystals operating as scintillating calorimeters, mainly sensitive to the Coherent Elastic Scattering of Neutrinos (CE$\nu$NS) against the Na and I nuclei. The low mass of the cryogenic detectors gives the experiment a sensitivity to close supernovae below 1kpc without pileup. They will see up to hundreds of CE$\nu$NS events from a supernova happening at 200pc. The crystals reside at the center of a cylindrical 230T water tank, instrumented with 30 photomultipliers. This tank acts as a passive and active shield able to detect the Cherenkov radiation induced by impinging charged particles from ambient and cosmogenic radioactivity. A supernova near the Milky Way Center (10kpc) will be easily detected inducing $\sim$60 measurable events, and the water tank will have a 3$\sigma$ sensitivity to supernovae up to 22kpc, seeing $\sim$10 events. This paper shows how, even without dedicated optimization, modern dark matter experiments will also play their part in the multi-messenger effort to detect the next galactic core-collapse supernova.

astro-ph.HE

High-precision mass measurements of the ground and isomeric states in $^{124,125}$Ag

The masses of the ground and isomeric states in $^{124,125}$Ag have been measured using the phase-imaging ion-cyclotron-resonance technique at the JYFLTRAP double Penning trap mass spectrometer. The ground states of $^{124}$Ag and $^{125}$Ag were found to be 30(250) keV and 250(430) keV less bound but 36 and 110 times more precise than in the Atomic Mass Evaluation 2020, respectively. The excitation energy of $^{124}$Ag$^{m}$, ${E_x = 188.2(25)}$ keV, was determined for the first time. The new precise mass values have been utilised to study the evolution of nuclear structure via two-neutron separation energies. The impact on the astrophysical rapid neutron capture process has been investigated via neutron-capture reaction rate calculations. The precision measurements indicate a more linear trend in two-neutron separation energies and reduce the mass-related uncertainties for the neutron-capture rate of $^{124}$Ag$(n,\gamma)^{125}$Ag by a factor of around 100. The new mass values also improve the mass of $^{123}$Pd, previously measured using $^{124}$Ag as a reference.

nucl-ex

Prominent bump in the two-neutron separation energies of neutron-rich lanthanum isotopes revealed by high-precision mass spectrometry

We report on high-precision atomic mass measurements of $^{148\text{-}153}$La and $^{151}$Ce performed with the JYFLTRAP double Penning trap using the Phase-Imaging Ion-Cyclotron-Resonance technique. The masses of $^{152,153}$La were experimentally determined for the first time. We confirm the sharp kink in the two-neutron separation energies at the neutron number ${N=93}$ in the cerium (${Z=58}$) isotopic chain. Our precision mass measurements of the most exotic neutron-rich lanthanum (${Z=57}$) isotopes reveal a sudden increase in two-neutron separation energies from ${N=92}$ to ${N=93}$. Unlike in the cerium isotopic chain, the kink is not sharp but extends to ${N=94}$ forming a prominent bump. The gain in energy is about 0.4 MeV, making it one of the strongest changes in two-neutron separation energies over the whole chart of nuclides, away from nuclear shell closures. The results call for further studies to elucidate the structure of neutron-rich lanthanum isotopes.

nucl-ex

Isochronous mass spectrometry at the RIKEN Rare-RI Ring facility

A dedicated isochronous storage ring, named the Rare-RI Ring, was constructed at the RI Beam Factory of RIKEN, aiming at precision mass measurements of nuclei located in uncharted territories of the nuclear chart. The Rare-RI Ring employs the isochronous mass spectrometry technique with the goal to achieve a relative mass precision of $10^{-6}$ within a measurement time of less than 1 ms. The performance of the facility was demonstrated through mass measurements of neutron-rich nuclei with well-known masses. Velocity or magnetic rigidity is measured for every particle prior to its injection into the ring, wherein its revolution time is accurately determined. The latter quantity is used to determine the mass of the particle, while the former one is needed for non-isochronicity corrections. Mass precisions on the order of $10^{-5}$ were achieved in the first commissioning, which demonstrates that Rare-RI Ring is a powerful tool for mass spectrometry of short-lived nuclei.

nucl-ex

Probing the N=104 midshell region for the r process via precision mass spectrometry of neutron-rich rare-earth isotopes with the JYFLTRAP double Penning trap

We have performed high-precision mass measurements of neutron-rich rare-earth Tb, Dy and Ho isotopes using the Phase-Imaging Ion-Cyclotron-Resonance technique at the JYFLTRAP double Penning trap. We report on the first experimentally determined mass values for $^{169}$Tb, $^{170}$Dy and $^{171}$Dy, as well as the first high-precision mass measurements of $^{169}$Dy and $^{169\text{-}171}$Ho. For $^{170}$Ho, the two long-lived ground and isomeric states were resolved and their mass measured, yielding an isomer excitation energy of $E_\text{exc}=150.8(54)$~keV. In addition, we have performed independent crosschecks of previous Penning-trap values obtained for $^{167\text{,} 168}$Tb and $^{167\text{,} 168}$Dy. We have extended the systematics of two-neutron separation energies to the neutron midshell at $N=104$ in all of the studied isotopic chains. Our updated and new mass measurements provide better mass-related constraints for the neutron-capture reaction rates relevant to the astrophysical rapid neutron capture (r) process. The r-process abundances calculated with the new mass values seem to produce a steeper minimum at A=170 and differ by around 15-30\% from the abundances computed with the Atomic Mass Evaluation 2020 values.

nucl-ex

Water Cherenkov muon veto for the COSINUS experiment: design and simulation optimization

COSINUS is a dark matter (DM) direct search experiment that uses sodium iodide (NaI) crystals as cryogenic calorimeters. Thanks to the low nuclear recoil energy threshold and event-by-event discrimination capability, COSINUS will address the long-standing DM claim made by the DAMA/LIBRA collaboration. The experiment is currently under construction at the Laboratori Nazionali del Gran Sasso, Italy, and employs a large cylindrical water tank as a passive shield to meet the required background rate. However, muon-induced neutrons can mimic a DM signal therefore requiring an active veto system, which is achieved by instrumenting the water tank with an array of photomultiplier tubes (PMTs). This study optimizes the number, arrangement, and trigger conditions of the PMTs as well as the size of an optically invisible region. The objective was to maximize the muon veto efficiency while minimizing the accidental trigger rate due to the ambient and instrumental background. The final configuration predicts a veto efficiency of 99.63 $\pm$ 0.16 $\%$ and 44.4 $\pm$ $5.6\%$ in the tagging of muon events and showers of secondary particles, respectively. The active veto will reduce the cosmogenic neutron background rate to 0.11 $\pm$ 0.02 cts$\cdot$kg$^{-1}$$\cdot$year$^{-1}$, corresponding to less than one background event in the region of interest for the whole COSINUS-1$\pi$ exposure of 1000 kg$\cdot$days.

physics.ins-det