arXiv Science⌕ Search

arXiv subjects

Yingtong Zhou

Publications and source records attributed to Yingtong Zhou.

3 recordsLinked to original sources

A liquid implant that grows into a stable scaffold in situ

Endovascular embolization requires materials that can pass through narrow microcatheters yet form stable, conformal occlusions within irregular vascular lesions, but reconciling these competing requirements remains challenging. Here we report a wirelessly activated liquid precursor whose final architecture is constructed only after target localization. A gallium-based liquid metal containing iron microparticles and gas microcavities remains deformable, magnetically navigable, and retrievable before activation. Wireless induction heating activates the internal reactive microenvironment, coupling gas-driven microcavity growth with oxidative mineralization of newly generated gallium interfaces to form a porous, self-supporting scaffold. In aneurysm and arteriovenous malformation models, activation enabled durable occlusion, aneurysm-neck healing, and six-month stability in a porcine aneurysm model. These findings establish post-delivery construction as a strategy for creating stable therapeutic implants from minimally invasive liquid precursors.

cond-mat.soft↗

An Evidence-Guided Framework for Tissue-Barrier Impedance Review: Deletion and Resistance Sensitivity

Reviewing tissue-barrier impedance requires connecting spectral anomalies with resistance estimates and experimental context. We present an evidence-guided framework that coordinates numerical checks and traceable actions for human review. In-house simulations assess the effect of removing flagged frequencies, public datasets test model adaptation, and local measurements demonstrate the review workflow. Removing flagged frequencies reduced resistance error under quadratic objectives, whereas robust fitting showed little average benefit from deletion and a mean error increase for endpoint-pair perturbations. High errors clustered around a few fitted circuit parameter sets, highlighting the value of examining parameter identifiability. Under the tested noise and perturbation conditions, these findings support robust full-spectrum estimation, flag-guided inspection, and matched sensitivity checks.

eess.SP↗

A Dynamic Parametric Simulator for Fetal Heart Sounds

Research on fetal phonocardiogram (fPCG) is challenged by the limited number of abdominal recordings, substantial maternal interference, and marked transmissioninduced signal attenuation that complicate reproducible benchmarking. We present a reproducible dynamic parametric simulator that generates long abdominal fPCG sequences by combining cycle-level fetal S1/S2 event synthesis with a convolutional transmission module and configurable interference and background noise. Model parameters are calibrated cyclewise from real abdominal recordings to capture beat-to-beat variability and to define data-driven admissible ranges for controllable synthesis. The generated signals are validated against real recordings in terms of envelope-based temporal structure and frequency-domain characteristics. The simulator is released as open software to support rapid, reproducible evaluation of fPCG processing methods under controlled acquisition conditions.

eess.SP↗