arXiv ScienceSearch

arXiv subjects

Yilin Luo

Publications and source records attributed to Yilin Luo.

13 recordsLinked to original sources

When Local Variance Optimality Is Not Enough: RoPE-Aligned Q/K Rotations for Dynamic 4-Bit Quantisation

Rotation-based post-training quantisation commonly applies an orthogonal transform across an entire attention head to reduce outlier-induced error. RoPE instead partitions each head into two-dimensional frequency pairs, raising the question of whether a transform respecting this decomposition can improve on full-head mixing. Prior work has established the per-pair rotations that commute with RoPE. We state the converse result that, for distinct frequencies, no other single-head orthogonal map commutes with RoPE. For the head-shared parameterisation used in our experiments, we then derive the rotation angle that minimises the larger channel variance under a pooled-covariance, position-averaged surrogate and verify that the implementation attains its analytic minimum. The evaluated head-shared pairwise configuration does not improve accuracy in the tested dynamic W4A4KV4 setting. Across four checkpoints, replacing the full-head Hadamard with this configuration increases perplexity at both short and long context lengths. Composing the pairwise rotation with the Hadamard satisfies the selected $\pm0.05$-PPL interval criterion under the default estimator. Estimating the shared angle from K alone improves pairwise-only on every checkpoint but does not close its gap to full-head mixing. The analytic objective controls a position-averaged second moment of a pooled calibration covariance, whereas the dynamic quantiser sets its step from a tokenwise group range. The pairwise transform also has only two-channel mixing support. Along a controlled interpolation from two-channel to full-head mixing, K range, relative quantisation error, and perplexity degradation decrease as support increases. These results show that optimality for a structured surrogate need not reduce quantisation error when the surrogate and mixing support are misaligned with the quantiser's scale-setting statistic.

cs.LG

Physics-Aware Neural Operators for Direct Inversion in 3D Photoacoustic Tomography

Learning physics-constrained inverse operators-rather than post-processing physics-based reconstructions-is a broadly applicable strategy for problems with expensive forward models. We demonstrate this principle in three-dimensional photoacoustic computed tomography (3D PACT), where current systems demand dense transducer arrays and prolonged scans, restricting clinical translation. We introduce PANO (PACT imaging neural operator), an end-to-end physics-aware neural operator-a deep learning architecture that generalizes across input sampling densities without retraining-that directly learns the inverse mapping from raw sensor measurements to a 3D volumetric image. Unlike two-step methods that reconstruct then denoise, PANO performs direct inversion in a single pass, jointly embedding physics and data priors. It employs spherical discrete-continuous convolutions to respect hemispherical sensor geometry and Helmholtz equation constraints to ensure physical consistency. PANO reconstructs high-quality images from both simulated and real data across diverse sparse acquisition settings, achieves real-time inference and outperforms the widely-used UBP algorithm by approximately 33 percentage points in cosine similarity on simulated data and 14 percentage points on real phantom data. These results establish a pathway toward more accessible 3D PACT systems for preclinical research, and motivate future in-vivo validation for clinical translation.

eess.IV

Validating Sequential Monte Carlo for Gravitational-Wave Inference

Nested sampling (NS) is the preferred stochastic sampling algorithm for gravitational-wave inference for compact binary coalenscences (CBCs). It can handle the complex nature of the gravitational-wave likelihood surface and provides an estimate of the Bayesian model evidence. However, there is another class of algorithms that meets the same requirements but has not been used for gravitational-wave analyses: Sequential Monte Carlo (SMC), an extension of importance sampling that maps samples from an initial density to a target density via a series of intermediate densities. In this work, we validate a type of SMC algorithm, called persistent sampling (PS), for gravitational-wave inference. We consider a range of different scenarios including binary black holes (BBHs) and binary neutron stars (BNSs) and real and simulated data and show that PS produces results that are consistent with NS whilst being, on average, 2 times more efficient and 2.74 times faster. This demonstrates that PS is a viable alternative to NS that should be considered for future gravitational-wave analyses.

astro-ph.IM

Rotational ultrasound and photoacoustic tomography of the human body

Imaging the human body's morphological and angiographic information is essential for diagnosing, monitoring, and treating medical conditions. Ultrasonography performs the morphological assessment of the soft tissue based on acoustic impedance variations, whereas photoacoustic tomography (PAT) can visualize blood vessels based on intrinsic hemoglobin absorption. Three-dimensional (3D) panoramic imaging of the vasculature is generally not practical in conventional ultrasonography with limited field-of-view (FOV) probes, and PAT does not provide sufficient scattering-based soft tissue morphological contrast. Complementing each other, fast panoramic rotational ultrasound tomography (RUST) and PAT are integrated for hybrid rotational ultrasound and photoacoustic tomography (RUS-PAT), which obtains 3D ultrasound structural and PAT angiographic images of the human body quasi-simultaneously. The RUST functionality is achieved in a cost-effective manner using a single-element ultrasonic transducer for ultrasound transmission and rotating arc-shaped arrays for 3D panoramic detection. RUST is superior to conventional ultrasonography, which either has a limited FOV with a linear array or is high-cost with a hemispherical array that requires both transmission and receiving. By switching the acoustic source to a light source, the system is conveniently converted to PAT mode to acquire angiographic images in the same region. Using RUS-PAT, we have successfully imaged the human head, breast, hand, and foot with a 10 cm diameter FOV, submillimeter isotropic resolution, and 10 s imaging time for each modality. The 3D RUS-PAT is a powerful tool for high-speed, 3D, dual-contrast imaging of the human body with potential for rapid clinical translation.

physics.med-ph

Document-Level Event Extraction with Definition-Driven ICL

In the field of Natural Language Processing (NLP), Large Language Models (LLMs) have shown great potential in document-level event extraction tasks, but existing methods face challenges in the design of prompts. To address this issue, we propose an optimization strategy called "Definition-driven Document-level Event Extraction (DDEE)." By adjusting the length of the prompt and enhancing the clarity of heuristics, we have significantly improved the event extraction performance of LLMs. We used data balancing techniques to solve the long-tail effect problem, enhancing the model's generalization ability for event types. At the same time, we refined the prompt to ensure it is both concise and comprehensive, adapting to the sensitivity of LLMs to the style of prompts. In addition, the introduction of structured heuristic methods and strict limiting conditions has improved the precision of event and argument role extraction. These strategies not only solve the prompt engineering problems of LLMs in document-level event extraction but also promote the development of event extraction technology, providing new research perspectives for other tasks in the NLP field.

cs.CL

De-aberration for transcranial photoacoustic computed tomography through an adult human skull

Noninvasive transcranial photoacoustic computed tomography (PACT) of the human brain, despite its clinical potential as a complementary technology to functional MRI, remains impeded by the acoustic distortion induced by the human skull. The distortion, which is attributed to the markedly different material properties of the skull relative to soft tissue, results in heavily aberrated PACT images -- a problem that has remained unsolved for the past two decades. Herein, we report the first successful experimental demonstration of the de-aberration of PACT images through an ex-vivo adult human skull using a homogeneous elastic model for the skull. Using only the geometry, position, and orientation of the skull, we faithfully de-aberrate the PACT images of light-absorbing phantoms acquired through an ex-vivo human skull for different levels of phantom complexity and positions. We also demonstrate the generality of our results by attaining a similar extent of de-aberration through a second ex-vivo human skull. Our work addresses the longstanding challenge of skull-induced aberrations in transcranial PACT and advances the field towards unlocking the full potential of transcranial human brain PACT.

physics.med-ph

Single-shot 3D photoacoustic computed tomography with a densely packed array for transcranial functional imaging

Photoacoustic computed tomography (PACT) is emerging as a new technique for functional brain imaging, primarily due to its capabilities in label-free hemodynamic imaging. Despite its potential, the transcranial application of PACT has encountered hurdles, such as acoustic attenuations and distortions by the skull and limited light penetration through the skull. To overcome these challenges, we have engineered a PACT system that features a densely packed hemispherical ultrasonic transducer array with 3072 channels, operating at a central frequency of 1 MHz. This system allows for single-shot 3D imaging at a rate equal to the laser repetition rate, such as 20 Hz. We have achieved a single-shot light penetration depth of approximately 9 cm in chicken breast tissue utilizing a 750 nm laser (withstanding 3295-fold light attenuation and still retaining an SNR of 74) and successfully performed transcranial imaging through an ex vivo human skull using a 1064 nm laser. Moreover, we have proven the capacity of our system to perform single-shot 3D PACT imaging in both tissue phantoms and human subjects. These results suggest that our PACT system is poised to unlock potential for real-time, in vivo transcranial functional imaging in humans.

physics.med-ph

Neural network-based image reconstruction in swept-source optical coherence tomography using undersampled spectral data

Optical Coherence Tomography (OCT) is a widely used non-invasive biomedical imaging modality that can rapidly provide volumetric images of samples. Here, we present a deep learning-based image reconstruction framework that can generate swept-source OCT (SS-OCT) images using undersampled spectral data, without any spatial aliasing artifacts. This neural network-based image reconstruction does not require any hardware changes to the optical set-up and can be easily integrated with existing swept-source or spectral domain OCT systems to reduce the amount of raw spectral data to be acquired. To show the efficacy of this framework, we trained and blindly tested a deep neural network using mouse embryo samples imaged by an SS-OCT system. Using 2-fold undersampled spectral data (i.e., 640 spectral points per A-line), the trained neural network can blindly reconstruct 512 A-lines in ~6.73 ms using a desktop computer, removing spatial aliasing artifacts due to spectral undersampling, also presenting a very good match to the images of the same samples, reconstructed using the full spectral OCT data (i.e., 1280 spectral points per A-line). We also successfully demonstrate that this framework can be further extended to process 3x undersampled spectral data per A-line, with some performance degradation in the reconstructed image quality compared to 2x spectral undersampling. This deep learning-enabled image reconstruction approach can be broadly used in various forms of spectral domain OCT systems, helping to increase their imaging speed without sacrificing image resolution and signal-to-noise ratio.

eess.IV

Deep learning-based virtual refocusing of images using an engineered point-spread function

We present a virtual image refocusing method over an extended depth of field (DOF) enabled by cascaded neural networks and a double-helix point-spread function (DH-PSF). This network model, referred to as W-Net, is composed of two cascaded generator and discriminator network pairs. The first generator network learns to virtually refocus an input image onto a user-defined plane, while the second generator learns to perform a cross-modality image transformation, improving the lateral resolution of the output image. Using this W-Net model with DH-PSF engineering, we extend the DOF of a fluorescence microscope by ~20-fold. This approach can be applied to develop deep learning-enabled image reconstruction methods for localization microscopy techniques that utilize engineered PSFs to improve their imaging performance, including spatial resolution and volumetric imaging throughput.

eess.IV

Recurrent neural network-based volumetric fluorescence microscopy

Volumetric imaging of samples using fluorescence microscopy plays an important role in various fields including physical, medical and life sciences. Here we report a deep learning-based volumetric image inference framework that uses 2D images that are sparsely captured by a standard wide-field fluorescence microscope at arbitrary axial positions within the sample volume. Through a recurrent convolutional neural network, which we term as Recurrent-MZ, 2D fluorescence information from a few axial planes within the sample is explicitly incorporated to digitally reconstruct the sample volume over an extended depth-of-field. Using experiments on C. Elegans and nanobead samples, Recurrent-MZ is demonstrated to increase the depth-of-field of a 63x/1.4NA objective lens by approximately 50-fold, also providing a 30-fold reduction in the number of axial scans required to image the same sample volume. We further illustrated the generalization of this recurrent network for 3D imaging by showing its resilience to varying imaging conditions, including e.g., different sequences of input images, covering various axial permutations and unknown axial positioning errors. Recurrent-MZ demonstrates the first application of recurrent neural networks in microscopic image reconstruction and provides a flexible and rapid volumetric imaging framework, overcoming the limitations of current 3D scanning microscopy tools.

physics.optics

Single-shot autofocusing of microscopy images using deep learning

We demonstrate a deep learning-based offline autofocusing method, termed Deep-R, that is trained to rapidly and blindly autofocus a single-shot microscopy image of a specimen that is acquired at an arbitrary out-of-focus plane. We illustrate the efficacy of Deep-R using various tissue sections that were imaged using fluorescence and brightfield microscopy modalities and demonstrate snapshot autofocusing under different scenarios, such as a uniform axial defocus as well as a sample tilt within the field-of-view. Our results reveal that Deep-R is significantly faster when compared with standard online algorithmic autofocusing methods. This deep learning-based blind autofocusing framework opens up new opportunities for rapid microscopic imaging of large sample areas, also reducing the photon dose on the sample.

eess.IV

Three-dimensional virtual refocusing of fluorescence microscopy images using deep learning

Three-dimensional (3D) fluorescence microscopy in general requires axial scanning to capture images of a sample at different planes. Here we demonstrate that a deep convolutional neural network can be trained to virtually refocus a 2D fluorescence image onto user-defined 3D surfaces within the sample volume. With this data-driven computational microscopy framework, we imaged the neuron activity of a Caenorhabditis elegans worm in 3D using a time-sequence of fluorescence images acquired at a single focal plane, digitally increasing the depth-of-field of the microscope by 20-fold without any axial scanning, additional hardware, or a trade-off of imaging resolution or speed. Furthermore, we demonstrate that this learning-based approach can correct for sample drift, tilt, and other image aberrations, all digitally performed after the acquisition of a single fluorescence image. This unique framework also cross-connects different imaging modalities to each other, enabling 3D refocusing of a single wide-field fluorescence image to match confocal microscopy images acquired at different sample planes. This deep learning-based 3D image refocusing method might be transformative for imaging and tracking of 3D biological samples, especially over extended periods of time, mitigating photo-toxicity, sample drift, aberration and defocusing related challenges associated with standard 3D fluorescence microscopy techniques.

cs.CV