arXiv Science⌕ Search

arXiv subjects

Xuetong Zhou

Publications and source records attributed to Xuetong Zhou.

2 recordsLinked to original sources

High-Temporal-Resolution Motion Correction in Magnetic Resonance Fingerprinting Using a Quantitative Scout and Compact Spiral Navigators

Motion correction in magnetic resonance fingerprinting (MRF) helps preserve the accuracy of quantitative maps; however, existing approaches provide motion updates only every 7-8 seconds. We propose a navigation framework that integrates compact k-space navigators throughout the MRF acquisition, enabling sub-second motion estimation at minimal sequence overhead. A 3D spiral-projection MRF sequence was augmented with three orthogonal spiral navigators inserted every 0.5 seconds, enabling motion estimation by comparing navigator signals with quantitative scout (Q-Scout) data, i.e., motion-free low-resolution k-space with matching contrast evolution. The Q-Scout is obtained via a rapid calibration during the dummy preparation period, incurring no additional scan time. Motion estimation is formulated as dictionary matching in a discriminant subspace with optimization refinement. The method was evaluated in simulation and in vivo for 1 mm isotropic brain 3D MRF at 3 T. Across 35 motion-corrupted acquisitions with motion-free references available, the proposed motion correction reduced MRF reconstruction normalized root-mean-square error (NRMSE) by 7.1% and increased the structural similarity index measure (SSIM) by 0.085. Motion estimates aligned with 8 second temporal-rate image-based navigation (mean absolute difference of 0.15 mm and 0.23 degrees), while the proposed method provided higher temporal resolution and improved motion correction. The proposed framework enables robust motion navigation in MRF at 0.5 second temporal resolution with minimal sequence overhead. By using contrast-consistent modeling and efficient inference, it improves the reliability of quantitative MRI under rapid, unpredictable motion.

eess.SP↗

A Flat Plasmonic Biosensing Interface on Optical Fiber End-Facet via SPP-MIM Hybridization

We found that the specific dispersion of metal-insulator-metal (MIM) waveguide allows the hybridization of surface plasmon polaritons (SPPs) and the waveguide, which is not possible with dielectric waveguides. The SPP-MIM hybridization structure forms such a meta-film that integrates the previously incompatible respective merits of SPR and LSPR, including flat interfaces, high sensitivities, short evanescent fields and easy coupling with confined light. On the other hand, to achieve stable and reproducible performance is one of the greatest unresolved challenges for the development of nanophotonic biosensors. We point out that the key is to obtain well-controlled biomolecular behaviors using simple physical interfaces, for which the SPP-MIM meta-film provides a capable solution. We embed the SPP-MIM meta-film with a plasmonic crystal cavity and integrate it on a single-mode fiber's end-facet to detect biomolecular interactions. This device demonstrates highly reproducible sensorgrams and convincing detection of biotinylated proteins at down to 30 fM, with the sensorgrams following the Langmuir model. By unprecedentedly having both high sensitivity and high reproducibility, our device proposal provides a comprehensive solution for optical fiber-tip plasmonic devices to turn into a useful industrial biosensing technology.

physics.optics↗