arXiv ScienceSearch

arXiv subjects

Xinxin Yu

Publications and source records attributed to Xinxin Yu.

2 recordsLinked to original sources

Monolithic integration of diverse crystalline thin films on diamond for near-junction thermal management

The pursuit of extreme miniaturization and high power in 6G RF front-ends has cast thermal dissipation as the central challenge. Here, we have demonstrated the monolithic integration of functionally distinct single-crystal thin films, including \b{eta}-Ga2O3, Si, GaN, and LiTaO3, onto a single diamond substrate using a multi-step transfer printing technique. Focusing on the critical \b{eta}-Ga2O3/diamond interface, we achieve an exceptional interfacial thermal conductance (ITC) of 149 MW m-2 K-1 through ultra-high vacuum (UHV) annealing, creating an atomically sharp interface featuring covalent bonding. Vibrational electron energy-loss spectroscopy (EELS) analysis combining with molecular dynamics (MD) simulations reveal that distinctive interfacial phonon modes at the \b{eta}-Ga2O3/diamond heterointerface dominate ultrahigh ITC. We experimentally demonstrate that by improving the ITC, the thermal resistance (Rth) of a diamond-based \b{eta}-Ga2O3 MOSFET is driven to a record-low value of 1.58 K mm W-1, underscoring the critical role of interface engineering in near-junction thermal management for diamond-integrated devices. This work demonstrates a scalable, diamond-based monolithic integration platform designed to solve the near-junction thermal challenges in high-power RF front-ends.

cond-mat.mtrl-sci

Information Entropy-Based Framework for Quantifying Tortuosity in Meibomian Gland Uneven Atrophy

In the medical image analysis field, precise quantification of curve tortuosity plays a critical role in the auxiliary diagnosis and pathological assessment of various diseases. In this study, we propose a novel framework for tortuosity quantification and demonstrate its effectiveness through the evaluation of meibomian gland atrophy uniformity,serving as a representative application scenario. We introduce an information entropy-based tortuosity quantification framework that integrates probability modeling with entropy theory and incorporates domain transformation of curve data. Unlike traditional methods such as curvature or arc-chord ratio, this approach evaluates the tortuosity of a target curve by comparing it to a designated reference curve. Consequently, it is more suitable for tortuosity assessment tasks in medical data where biologically plausible reference curves are available, providing a more robust and objective evaluation metric without relying on idealized straight-line comparisons. First, we conducted numerical simulation experiments to preliminarily assess the stability and validity of the method. Subsequently, the framework was applied to quantify the spatial uniformity of meibomian gland atrophy and to analyze the difference in this uniformity between \textit{Demodex}-negative and \textit{Demodex}-positive patient groups. The results demonstrated a significant difference in tortuosity-based uniformity between the two groups, with an area under the curve of 0.8768, sensitivity of 0.75, and specificity of 0.93. These findings highlight the clinical utility of the proposed framework in curve tortuosity analysis and its potential as a generalizable tool for quantitative morphological evaluation in medical diagnostics.

cs.CV