Network Reconfiguration Impact on Renewable Energy System and Energy Storage System in Day-Ahead Scheduling

Renewable energy sources (RES) has gained significant interest in recent years. However, due to favourable weather conditions, the RES is installed in remote locations with limited transmission capacity. As a result, it can lead to major curtailments of the free resource when the network is congested. Therefore, energy storage system (ESS) is considered as a viable solution to store energy and address the intermittent nature of RES though ESS is often distributed and may not be geographically close to RES. Therefore, ESS may also suffer from limited transmission capacity due to network congestion. Currently, grid operators overlook network flexibility as a congestion management tool in day-ahead scheduling. This paper addresses these issues and studies the benefits of introducing network reconfiguration (NR) as a preventive and corrective action for transmission flexibility in day-ahead stochastic security-constrained unit-commitment (SSCUC-PC) while considering a multi-scenario RES output. Simulation results demonstrate that NR can lower total system cost, reduce RES curtailments and utilize ESS for better impact by alleviating network congestion in both base-case and post-contingency networks.

cs.NI↗

An Accelerated-Decomposition Approach for Security-Constrained Unit Commitment with Corrective Network Reconfiguration- Part II: Results and Discussion

This paper presents a novel approach to handle the computational complexity in security-constrained unit commitment (SCUC) with corrective network reconfiguration (CNR) to harness the flexibility in transmission networks. This is achieved with consideration of scalability through decomposing the SCUC/SCUC-CNR formulation and then fast screening non-critical sub-problems. This is compared against the extensive formulations of SCUC and SCUC-CNR to show the advantages of the proposed typical-decomposition and accelerated-decomposition approaches to SCUC and SCUC-CNR respectively. Simulation results on the IEEE 24-bus system show that the proposed methods are substantially faster without the loss in solution quality. The proposed accelerated-decomposition approaches can be implemented for large power systems as they have great performance in the scalability tests on the IEEE 73-bus system and the Polish system when compared against the respective extensive formulations and typical-decomposition approaches. Overall, a dynamic post-contingency network can substantially alleviate network congestion and lead to a lower optimal cost.

math.OC↗

Enhancing System Flexibility through Corrective Demand Response in Security-Constrained Unit Commitment

Currently, system operators implement demand response by dispatching controllable loads for economic reasons in day-ahead scheduling. Particularly, demand shifting from peak hours when the cost of electricity is higher to non-peak hours to maintain system reliability by flattening the load profile. However, the system flexibility and economic benefits of such action in post-contingency scenarios are not explicitly considered in short-term operations. Hence, this paper highlights the benefits of demand response as a corrective action for potential post-contingency emergencies in day-ahead scheduling. A security-constrained unit commitment (SCUC) model which considers the flexibility offered through corrective demand response (CDR) to maintain system reliability when a line or generator outage occurs is proposed. The proposed model was tested on IEEE 24-bus system where simulation results point to significant total cost savings in daily operations. Moreover, the results point to better long-term reliability of generators along with the ability to use existing system flexibility and serve higher critical demands in base-case when CDR is implemented.

math.OC↗

Dynamic Estimation of Power System Inertia Distribution Using Synchrophasor Measurements

Integration of intermittent renewable energy sources in modern power systems is increasing very fast. Replacement of synchronous generators with zero-to-low variable renewables substantially decreases the system inertia. In a large system, inertia distribution may vary significantly, areas of low inertia are more susceptible to frequency deviation, posing risks of load shedding and generation trip. Therefore, it is necessary for operators to evaluate and quantify the system inertia and its distribution in real time. This paper proposes a novel synchronized phasor measurement units (PMUs)-based dynamic system inertia estimation method. The proposed inertia estimation method is derived using electrical distance and clustering algorithm, which considers the impact of location of measurements relative to in-feed load and impact of oscillations. The center of inertia (COI) area and area of low inertia are also determined during the estimation. Numerical simulations are conducted on the IEEE 24-bus system with various load profiles using Transient Security Analysis Tools (TSAT), a core module of the DSATools, which demonstrate the efficacy of the proposed approach.

eess.SP↗

A Novel Real-Time Energy Management Strategy for Gird-Friendly Microgrid: Harnessing Internal Fluctuation Internally

Typically, a large portion of microgrid generating capacity is from variable renewable resources that are greatly impacted by the environment and can be intermittent as well as stochastic. This would result in uncertainty of microgrid net-load, and negatively affect the grid reliability. A two-phase real-time energy management strategy for networked microgrid is proposed in this paper to address microgrid internal fluctuation internally, which enables a microgrid to become grid-friendly. The proposed strategy is based on coordination between the real-time dispatch (RTD) phase and the real-time control (RTC) phase. In the RTD phase, model predictive control (MPC) is used to optimally dispatch microgrid resources in the current time interval while considering near future situations. The RTC phase addresses microgrid internal net-load fluctuation with fast-acting batteries, which aims to maintain a constant tie-line power flow between the main grid and the microgrid for the current dispatch interval. Numerical simulations conducted on ten different net-load scenarios can demonstrate the performance of the proposed two-phase energy management strategy that will enable a microgrid to operate as a controllable asset with static electricity consumption or production in an economic dispatch interval from the perspective of the bulk grid operator.

eess.SY↗

Benefits and Cyber-Vulnerability of Demand Response System in Real-Time Grid Operations

With improvement in smart grids through two-way communication, demand response (DR) has gained significant attention due to the inherent flexibility provided by shifting non-critical loads from peak periods to off-peak periods, which can greatly improve grid reliability and reduce cost of energy. Operators utilize DR to enhance operational flexibility and alleviate network congestion. However, the intelligent two-way communication is susceptible to cyber-attacks. This paper studies the benefits of DR in security-constrained economic dispatch (SCED) and then the vulnerability of the system to line overloads when cyber-attack targets DR signals. This paper proposes a false demand response signal and load measurement injection (FSMI) cyber-attack model that sends erroneous DR signals while hacking measurements to make the attack undetectable. Simulation results on the IEEE 24-bus system (i) demonstrate the cost-saving benefits of demand response, and (ii) show significant line overloads when the demand response signals are altered under an FSMI attack.

eess.SY↗

Reducing Congestion-Induced Renewable Curtailment with Corrective Network Reconfiguration in Day-Ahead Scheduling

Renewable energy sources (RES) has gained a lot of interest recently. The limited transmission capacity serving RES often leads to network congestion since they are located in remote favorable locations. As a result, when poorly scheduled, the intermittent nature of RES may result in high curtailments of the free resource. Currently, grid operators utilize a static network when performing day-ahead scheduling and ignore transmission flexibility. This paper explores the possibility of utilizing network reconfiguration as a corrective action to reduce the transmission congestion and thereby the reduction of RES curtailments in day-ahead scheduling. To facilitate the RES integration in the grid, a stochastic N-1 security-constrained unit-commitment with corrective network reconfiguration (SSCUC-CNR) is modelled. SSCUC-CNR model is studied on a modified IEEE 24-bus system with RES. The simulation results demonstrate that CNR not only leads to a lower cost solution by reducing network congestion but also facilitates RES integration by reducing congestion-induced curtailments in high penetration cases. Emission studies demonstrate that more green generators are committed resulting in reduced carbon emissions when CNR is implemented.

math.OC↗

Security Constrained Unit Commitment with Corrective Transmission Switching

Traditionally, power system operations use a static network to deliver power and meet demand optimally. Network topology reconfiguration through transmission switching (TS) has gained significant interest recently to reduce the operational cost of power system operations. However, implementation of TS also causes large disturbance in the network and as a result the use of corrective transmission switching (CTS) in response to power system contingencies is currently being researched extensively. This paper emphasizes the importance of CTS to accomplish flexible transmission in N-1 security-constrained unit commitment (SCUC) model. An N-1 SCUC mathematical model implementing a dynamic network in the post-contingency scenario is proposed as opposed to current industry practices of static network in short-term operations. The proposed model is tested and validated on the IEEE 24-bus system. The proposed model results in cost-effective implementation and leads to overall reduced cost, and congestion reduction in the post-contingency scenario.

math.OC↗

Sensitivity Factors based Transmission Network Topology Control for Violation Relief

Transmission networks consist of thousands of branches for large-scale real power systems. They are built with a high degree of redundancy for reliability concern. Thus, it is very likely that there exist various network topologies that can deliver continuous power supply to consumers. The optimal transmission network topology could be very different for different system conditions. Transmission network topology control (TNTC) can provide the operator with an additional option to manage network congestion, reduce losses, relieve violation, and achieve cost saving. This paper examines the benefits of TNTC in reducing post-contingency overloads that are identified by real-time contingency analysis (RTCA). The procedure of RTCA with TNTC is presented and two algorithms are proposed to determine the candidate switching solutions. Both algorithms use available system data: sensitivity factors or shifting factors. The proposed two TNTC approaches are based on the transmission switching distribution factor (TSDF) and flow transfer distribution factor (FTDF) respectively. FTDF based TNTC approach is an enhanced version of TSDF based TNTC approach by considering network flow distribution. Numerical simulations demonstrate that both methods can effectively relieve flow violations and FTDF outperforms TSDF.

math.OC↗

Enhancing Power System Cyber-Security with Systematic Two-Stage Detection Strategy

State estimation estimates the system condition in real-time and provides a base case for other energy management system (EMS) applications including real-time contingency analysis and security-constrained economic dispatch. Recent work in the literature shows malicious cyber-attack can inject false measurements that bypass traditional bad data detection in state estimation and cause actual overloads. Thus, it is very important to detect such cyber-attack. In this paper, multiple metrics are proposed to monitor abnormal load deviations and suspicious branch flow changes. A systematic two-stage approach is proposed to detect false data injection (FDI) cyber-attack. The first stage determines whether the system is under attack while the second stage identifies the target branch. Numerical simulations verify that FDI can cause severe system violations and demonstrate the effectiveness of the proposed two-stage FDI detection (FDID) method. It is concluded that the proposed FDID approach can efficiently detect FDI cyber-attack and identify the target branch, which will substantially improve operators situation awareness in real-time.

eess.SY↗

Stochastic Optimal Power Flow with Network Reconfiguration: Congestion Management and Facilitating Grid Integration of Renewables

There has been a significant growth of variable renewable generation in the power grid today. However, the industry still uses deterministic optimization to model and solve the optimal power flow (OPF) problem for real-time generation dispatch that ignores the uncertainty associated with intermittent renewable power. Thus, it is necessary to study stochastic OPF (SOPF) that can better handle uncertainty since SOPF is able to consider the probabilistic forecasting information of intermittent renewables. Transmission network congestion is one of the main reasons for renewable energy curtailment. Prior efforts in the literature show that utilizing transmission network reconfiguration can relieve congestion and resolve congestion-induced issues. This paper enhances SOPF by incorporating network reconfiguration into the dispatch model. Numerical simulations show that renewable curtailment can be avoided with the proposed network reconfiguration scheme that relieves transmission congestion in post-contingency situations. It is also shown that network reconfiguration can substantially reduce congestion cost, especially the contingency-case congestion cost.

math.OC↗

Transmission Expansion Planning with Seasonal Network Optimization

Transmission expansion planning (TEP) is critical for the power grid to meet fast growing demand in the future. Traditional TEP model does not utilize the flexibility in the transmission network that is considered as static assets. However, as the load profile may have different seasonal patterns, the optimal network configuration could be very different for different seasons in the planning horizon. Therefore, this paper proposes to incorporate seasonal network optimization (SNO) into the traditional TEP model. SNO dynamically optimizes the network for each season of each planning epoch. Two TEP-SNO models are proposed to investigate the benefits of optimizing the status of (i) existing branches, and (ii) existing and new branches, respectively. Numerical simulations demonstrate the effectiveness of the proposed TEP-SNO models. It is shown that SNO can improve system operational efficiency, defer investment of new transmission elements, and reduce the total cost.

math.OC↗

Enhanced Energy Management System with Corrective Transmission Switching Strategy. Part I: Methodology

The flexibility in transmission networks is not fully utilized and reflected in existing energy management systems (EMSs). Corrective transmission switching (CTS) is proposed in this two-part paper to enable EMS to take advantage of the flexibility in transmission systems in a practical way. This paper proposes two EMS procedures: 1) Procedure-A connects real-time security-constrained economic dispatch (RT SCED) with real-time contingency analysis (RTCA), which is consistent with industrial practice; 2) Procedure-B, an enhanced version of Procedure-A, includes CTS in EMS with the proposed concept of branch pseudo limit used in RT SCED. Part-I of this paper presents the methodology while Part-II includes detailed results analysis. It is demonstrated that Procedure-A can effectively eliminate the potential post-contingency overloads identified by RTCA and Procedure-B can achieve significant congestion cost reduction with consideration of CTS in RT SCED. Numerical simulations also illustrate that integrating CTS into RT SCED would improve social welfare.

math.OC↗

Enhanced Energy Management System with Corrective Transmission Switching Strategy. Part II: Results and Discussion

This paper presents a novel procedure for energy management system (EMS) that can utilize the flexibility in transmission network in a practical way. With the proposed enhanced EMS procedure, the reliability benefits that are provided by corrective transmission switching (CTS) in real-time contingency analysis (RTCA) can be translated into significant cost savings in real-time security-constrained economic dispatch (RT SCED). Simulation results show the congestion cost with consideration of CTS is largely reduced as CTS can relieve potential post-contingency network violations. The effects of integrating CTS in existing EMS procedure on markets are also analyzed. In conclusion, this two-part paper shows that CTS can achieve substantial reliability benefits, as well as significant cost savings.

math.OC↗

Data Driven Linearized AC Power Flow Model with Regression Analysis

Full AC power flow model is an accurate mathematical model for representing the physical power systems. In practice, however, the utilization of this model is limited due to the computational complexity associated with its nonlinear and nonconvexity characteristics. An alternative linearized DC power flow model is widely used in the power system operation and planning tools. However, when reactive power and voltage magnitude are of concern, DC power flow model will be useless. Therefore, a linearized AC (LAC) power flow model is needed to address this issue. This paper first introduces a regular LAC model. Subsequently, with the advance in regression analysis technique, a data driven linearized AC (DLAC) model is proposed to improve the regular LAC model. Numerical simulations conducted on the Tennessee Valley Authority (TVA) system demonstrate the performance and effectiveness of the proposed DLAC model.

eess.SY↗

Real-Time Contingency Analysis with Corrective Transmission Switching - Part I: Methodology

Transmission switching (TS) has gained significant attention recently. However, barriers still remain and must be overcome before the technology can be adopted by the industry. The state of the art challenges include AC feasibility and performance, computational complexity, the ability to handle large-scale real power systems, and dynamic stability. This two-part paper investigates these challenges by developing an AC TS-based real-time contingency analysis (RTCA) tool that can handle large-scale systems within a reasonable time. The tool proposes multiple corrective switching actions, after detection of a contingency with potential violations. To reduce the computational complexity, three heuristic algorithms are proposed to generate a small set of candidates for switching. Parallel computing is implemented to further speed up the solution time. Furthermore, stability analysis is performed to check for dynamic stability of proposed TS solutions. Part I of the paper presents a comprehensive literature review and the methodology. The promising results, tested on the Tennessee Valley Authority (TVA) system and actual energy management system (EMS) snapshots from Pennsylvania New Jersey Maryland (PJM) and the Electric Reliability Council of Texas (ERCOT), are presented in Part II. It is concluded that RTCA with corrective TS significantly reduces potential post-contingency violations and is ripe for industry adoption.

cs.OH↗

Real-Time Contingency Analysis with Corrective Transmission Switching - Part II: Results and Discussion

This paper presents the performance of an AC transmission switching (TS) based real-time contingency analysis (RTCA) tool that is introduced in Part I of this paper. The approach quickly proposes high quality corrective switching actions for relief of potential post-contingency network violations. The approach is confirmed by testing it on actual EMS snapshots of two large-scale systems, the Electric Reliability Council of Texas (ERCOT) and the Pennsylvania New Jersey Maryland (PJM) Interconnection; the approach is also tested on data provided by the Tennessee Valley Authority (TVA). The results show that the tool effectively reduces post-contingency violations. Fast heuristics are used along with parallel computing to reduce the computational difficulty of the problem. The tool is able to handle the PJM system in about five minutes with a standard desktop computer. Time-domain simulations are performed to check system stability with corrective transmission switching (CTS). In conclusion, the paper shows that corrective switching is ripe for industry adoption. CTS can provide significant reliability benefits that can be translated into significant cost savings.