arXiv ScienceSearch

arXiv subjects

Xiaofeng Yang

Publications and source records attributed to Xiaofeng Yang.

At least 19 recordsLinked to original sources

Interacting dark energy constraints from Fermi GRBs and Pantheon+ SNe Ia with full GRB covariance

The standard $Λ$CDM model faces long-standing theoretical and observational problems, such as the Hubble tension, which motivate extensions beyond $Λ$CDM, including interacting dark energy (IDE). Type Ia supernovae (SNe Ia) are precise probes of the late-time expansion history, while gamma-ray bursts (GRBs) can extend the Hubble diagram to higher redshifts. However, GRB cosmology depends on careful calibration and uncertainty modeling. Using an Amati relation calibrated with the corresponding low-redshift GRBs, we construct distance moduli for the high-redshift subsets of the 15-year \textit{Fermi}/GBM GOLD and FULL samples and combine them with Pantheon+ SNe Ia to compare flat $Λ$CDM, $w$CDM, IDE-$ρ_{\rm de}$, and IDE-$ρ_{\rm c}$ models. The covariance of the calibrated Amati intercept and slope is propagated into a full, non-diagonal GRB distance-modulus covariance, and an effective residual scatter, $σ_{\rm res,μ}$, is fitted jointly with the cosmological parameters. The GOLD and FULL samples yield very similar constraints on the main cosmological parameters. With either the full or diagonal GRB covariance, the IDE models do not improve likelihood sufficiently to compensate for their additional parameters, and the BIC favors $Λ$CDM. Removing the Planck prior on $ω_b$ leaves the main cosmological constraints essentially unchanged. A SNe-only comparison shows that the additional constraining power of the GRBs is generally modest. Fixing $σ_{\rm res,μ}=0$ produces unacceptable GRB fits for all four models. Current GRB and Pantheon+ distance measurements provide no significant evidence for either of the two IDE interactions considered here.

astro-ph.CO

A radiographic world model for clinical reasoning and evidence generation

Medical imaging artificial intelligence (AI) is commonly developed as separate mappings from radiographs to diagnostic outputs or from clinical descriptions to generated images, although both arise from the same underlying radiographic state. A world-model formulation instead seeks to learn an internal representation of this state that can support both clinical readout and conditional simulation of radiographic observations. Here we introduce MedDream, a radiographic world model that learns a shared continuous latent state from paired chest radiograph-text observations for diagnostic reasoning and report-conditioned evidence generation. MedDream was pretrained on 2.65 million leakage-controlled chest radiograph-text pairs curated from 4.40 million candidates. Across eight clinical datasets and two independent reader cohorts, MedDream outperformed leading diagnostic and generative comparators. For diagnostic reasoning, MedDream showed strong generalization across disease recognition, label-scarce adaptation, severity assessment, and localization, while MedDream-supported review increased mean resident concordance with independent radiologist consensus from 56.3% to 63.0%. For evidence generation, MedDream produced radiographs that preserved clinically relevant pathology and improved downstream performance on held-out real data, with synthetic augmentation increasing external VinDr-CXR macro-AUROC from 76.4% to 81.4%. More importantly, conditioning generation on prespecified subgroup performance gaps enabled targeted evidence construction, increasing weighted F1 by 3.1 percentage points in Asian patients, whereas matched-volume unguided augmentation decreased it by 2.3 points. These findings establish radiographic world models as a path toward medical AI that learns clinically meaningful internal states for interpreting, simulating, and constructing evidence for clinical use.

cs.AI

Studies on the dark sector interaction from joint analysis of cosmological probes

We test whether constraints on the nonlinear interaction $ξ$IDE are stable under different treatments of the Type Ia supernovae absolute calibration. \textit{Fermi} GRBs measurements and the Amati-relation parameters are fitted jointly with PantheonPlus SNe Ia, DESI DR2 BAO, and an updated cosmic-chronometer compilation. We compare the PantheonPlus-SH0ES route, which retains the SN absolute calibration, with the PantheonPlus-only route, in which the SN absolute magnitude is analytically marginalized. The GOLD GRB sample is adopted for the main analysis, while the FULL GRB sample is used to assess sample dependence. For the interaction parameter $γ\equivξ+3w$, where $γ=0$ denotes the non-interacting limit, the GOLD sample gives $γ=1.453^{+1.297}_{-1.597}$ for the PantheonPlus-SH0ES and $γ=-0.634^{+1.668}_{-2.486}$ for the PantheonPlus-only. Although the posterior medians correspond to opposite directions of energy transfer, neither route excludes $γ=0$ at 68\% credibility, and the reconstructed interaction rate remains consistent with zero over the redshift range considered. Replacing the GOLD sample with the FULL sample produces negligible changes in the interaction constraints. Moreover, $w$CDM and CPL achieve likelihood improvements comparable to that of $ξ$IDE, while the information criteria do not consistently favor the interacting model. A redshift-bin diagnostic finds no significant redshift evolution of the Amati relation. We find no compelling evidence for a dark sector interaction that is robust to the choice of SN calibration or specifically favored over noninteracting dark energy extensions.

astro-ph.CO

Measurement of the Weyl Potential Evolution and $E_G$ Statistic from KiDS-1000, BOSS and 2dFLenS

A recently developed model-independent approach to measuring the Weyl potential has shown some tensions with $Λ$CDM (Lambda Cold Dark Matter) in DES (Dark Energy Survey) Y3 data. We apply this framework to Kilo-Degree Survey (KiDS-1000) weak lensing and BOSS/2dFLenS galaxy clustering using the KiDS Cosmology Analysis Pipeline (KCAP) in two redshift bins. To apply this method to the BOSS spectroscopic wedges, we take the early-time power spectrum from a redshift where General Relativity (GR) is recovered and jointly fit the late-time observables $\hat{b}$, $\hat{f}$, and $\hat{J}$. With Planck18 priors, the CMASS measurement of $\hat{J}$ is $1.50σ$ below the GR prediction, while the LOWZ measurement remains consistent with it. The decrease in the central value of $\hat{J}$ from LOWZ to CMASS provides a mild indication of the previously reported ``Lensing is low'' behavior. Without Planck18 priors, we obtain $E_G(0.38)=0.503\pm0.054$ and $E_G(0.61)=0.444\pm0.054$, both consistent with GR. Furthermore, phenomenological gravity tests also show no significant preference for modified gravity.

astro-ph.CO

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

cs.CV

MRI super-resolution in ten sampling steps using a diffusion bridge model

Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions.

cs.CV

Text-Guided Refinement of Multi-sequence Glioma Subregion Segmentation with a Vision-Language Foundation Model

Background: Accurate glioma subregion delineation is important for radiotherapy planning and longitudinal monitoring, but manual contour correction is time-consuming. Models such as nnU-Net may generalize imperfectly and lack clinician-directed text correction. Purpose: We investigated adapting a three-dimensional (3D) vision-language foundation model for text-guided brain tumor segmentation refinement. Methods: We developed a lightweight VoxTell-based framework. Pretrained VoxTell generated initial masks. Oracle prompts derived from segmentation errors encoded target, action, location, imaging evidence, edit size, and preservation constraints. Frozen Qwen/VoxTell prompt embeddings were injected through trainable projections into its multiscale decoder conditioning; other weights remained frozen. Training, validation, and testing used 901, 100, and 250 BraTS-GLI cases. Cross-dataset transfer was evaluated on 100 meningioma, metastasis, pediatric tumor, and UPENN-GBM cases. Results: On the internal test set using post-contrast T1-weighted input, correct instructions improved subregion Dice similarity coefficient (DSC; enhancing tumor, edema, and necrotic/non-enhancing core) from $0.774\pm0.158$ to $0.796\pm0.137$. They outperformed blank prompts ($0.762\pm0.155$; Holm-adjusted $p<0.001$, $d_z=0.71$) and contradictory prompts ($0.770\pm0.163$; $p<0.001$, $d_z=0.48$). In cross-dataset testing, correct instructions improved DSC from $0.527\pm0.287$ to $0.550\pm0.278$ and outperformed contradictory instructions ($0.504\pm0.275$; $p<0.001$, $d_z=0.43$). Conclusion: A 3D vision-language foundation model can perform instruction-guided refinement of glioma subregion segmentations. Sensitivity to correct, blank, and contradictory prompts suggests text-dependent contour editing rather than nonspecific post-processing, supporting further evaluation as a clinician-in-the-loop tool.

cs.CV

Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration

Head-and-neck (HN) proton therapy is highly sensitive to anatomical change over a 4-to-6-week course, as tumor shrinkage, weight loss, and setup variation can misposition the Bragg peak near critical organs such as the parotids, oral cavity, brainstem, and spinal cord, leading to target underdosing or organ-at-risk overdosing. Online adaptive proton therapy replans on the anatomy of the day, yet standard workflows rely on offline replanning that requires repeated CT acquisition and roughly a week of preparation, adding burden, cost, and delay. We investigate whether a patient's treatment-day anatomy can be predicted before image acquisition by transferring longitudinal change from a population database. We propose a digital-twin framework built on a pretrained foundation-model deformable registration network used without patient-specific training. A first registration aligns a prior patient's planning CT to the target and carries the prior's during-treatment quality assurance CT (QACT) into the target frame; a second registration estimates the prior's planning-to-QACT change, which is then applied to the target's own planning CT to synthesize predicted CTs (pdCTs) with propagated contours. Using 88 HN patients, each with a planning CT and three QACTs, we show that pdCTs better match treatment-day anatomy than the static planning CT. Compared with the planning CT alone, normalized cross-correlation improves by 22.8%, Dice for organs-at-risk by 20.2%, and CT-number error decreases by 23.4%. Gains are largest for patients with major anatomical change and negligible when anatomy is stable. This cross-patient motion transfer leverages the digital-twin concept to anticipate treatment-day anatomy, enabling personalized online adaptive proton therapy without repeated imaging.

physics.med-ph

Circulating Lymphocytes Preservation in Lung Cancer Stereotactic Body Radiation Therapy with Ultra-Fast Proton Delivery Using Modularized Pin Ridge Filters

Purpose: Radiation-induced lymphopenia is an increasingly recognized toxicity in lung radiotherapy and has been linked to radiation exposure to circulating lymphocytes (CL). In intensity-modulated proton therapy (IMPT), prolonged pencil beam scanning (PBS) delivery may increase CL dose. We recently developed a patient-specific pin ridge filter (pRF) framework that enables ultra-fast proton delivery with a single beam energy. This study evaluated whether pRF-based lung stereotactic body radiotherapy (SBRT) plans delivered at conventional (pRFCONV) and FLASH dose rates (pRFFLASH) improve immune sparing using time-resolved blood dose accumulation and CL survival modeling. Methods: pRF plans were created for 10 lung SBRT patients previously treated with IMPT. PBS delivery simulations modeled spot delivery, scanning, and energy switching. Blood dose-volume histograms (bDVHs) were calculated with the hematological dose framework. CL survival fractions (SF) were estimated from bDVHs with saturation and linear-quadratic models derived from in-vitro survival data for CD4/CD8 CL. Results: Compared with IMPT, pRFCONV/pRFFLASH plans reduced delivery time (mean reductions: 85.3/99.9%) and irradiated blood volume per fraction (mean reductions: 52.9/81.3%). pRFCONV/pRFFLASH plans reduced blood V5cGy by 26.4/39.4%, and V50cGy by 4.5/6.9%, respectively. pRF plans improved modeled CL survival across all models and subpopulations. Unstimulated CD4/CD8 CL had the largest SF differences, for which mean saturation-model SF improved by 7.9/8.6% for pRFCONV (p=0.03/0.02) and 9.6/10.4% for pRFFLASH (p=0.02/0.01), respectively. Conclusion: pRF plans improved modeled CL survival by significantly shortening delivery time and reducing irradiation of circulating blood. Our findings suggest that pRF's ultra-fast delivery may provide a practical strategy for immune sparing in proton lung SBRT.

physics.med-ph

MedLVR: Latent Visual Reasoning for Reliable Medical Visual Question Answering

Medical vision--language models (VLMs) have shown strong potential for medical visual question answering (VQA), yet their reasoning remains largely text-centric: images are encoded once as static context, and subsequent inference is dominated by language. This paradigm is fundamentally limited in clinical scenarios, where accurate answers often depend on subtle, localized visual evidence that cannot be reliably preserved in static embeddings. We propose \textsc{MedLVR}, a latent visual reasoning framework that introduces an explicit visual evidence state into autoregressive decoding. Instead of relying solely on text-based intermediate reasoning, \textsc{MedLVR} interleaves a short latent reasoning segment within the decoder by reusing hidden states as continuous latent steps, enabling iterative preservation and refinement of query-relevant visual evidence before answer generation. To support effective visual supervision, we adopt a two-stage training strategy: region of interest (ROI)-supervised fine-tuning aligns latent states with clinically relevant image evidence, and Visual-Latent Policy Optimization (VLPO) further optimizes latent reasoning and answer generation under outcome-level rewards. Experiments on OmniMedVQA and five external medical VQA benchmarks show that \textsc{MedLVR} consistently outperforms recent reasoning baselines and improves the average score over the Qwen2.5-VL-7B backbone from 48.3\% to 53.4\%. These results show that latent visual reasoning provides an effective mechanism for preserving diagnostically relevant visual evidence and improving the reliability of medical VQA.

cs.CV

One-for-All Adaptive Radiotherapy Planning Agent: A Foundation Framework for Daily CBCT-guided Radiotherapy

In this work, we introduce the One-for-All Adaptive Radiotherapy Planning Agent, a unified foundation-model-based system that performs complete, treatment-specific online adaptive planning directly from daily cone-beam CT in under two minutes. The agent first autonomously predicts all essential planning components, including synthetic CT generation, multimodal alignment, and tumor/organ segmentation. It then intelligently leverages these outputs to execute the final clinical plan design, providing a comprehensive, automated solution for daily treatment. We also demonstrate that the agent enables clinicians to define planning with intent and intervene at critical decision points, ensuring a "human-in-the-loop" framework that generates acceptable plans before final approval. Evaluated on multiple datasets spanning head-and-neck, lung, abdominal, and prostate cancers with both photon and proton therapy, the proposed framework achieves clinically acceptable accuracy and plan quality comparable to clinically generated treatment plans, with target dose errors (D98) generally within 2.0 Gy of the reference plan. The strong performance of the One-for-All agent highlights the promise of a unified foundation-model approach and opens opportunities for fast, scalable, and fully automated online adaptive radiotherapy across diverse clinical scenarios.

physics.med-ph

Artificial Intelligence Across the Cardiac Amyloidosis Diagnostic Pathway: From Single-Modality Detection to Multimodal Clinical Integration

Cardiac amyloidosis (CA) is increasingly recognized but remains substantially underdiagnosed, because its clinical and imaging phenotype overlaps with more common cardiomyopathies. Definitive subtype assignment and management further require integration of multimodal evidence to distinguish transthyretin from light chain disease. Machine learning and deep learning have been applied across the diagnostic and management pathway. These applications span ECG, echocardiography, and health record-based case finding, as well as CMR and nuclear interpretation, including SPECT/CT biomarker quantification, prognostic modeling, and treatment response assessment. This narrative review synthesizes these studies by clinical tasks, namely screening, detection, quantification, prognosis, and treatment response monitoring, rather than by input modality. This task-based organization clarifies why apparently similar AI models require different cohorts, reference standards, evaluation metrics, and implementation thresholds. The evidence reveals a maturity gradient. Binary detection and AI assisted quantification on bone scintigraphy and SPECT/CT are closest to clinical translation. Detection is supported by large externally validated cohorts, and quantification by interpretable, outcome linked measurement of myocardial tracer burden. By contrast, subtype aware classification, prognostic risk stratification, and treatment response monitoring remain at an early stage. These tasks are limited by small cohorts, enriched retrospective designs, heterogeneous labels, incomplete external validation, and uncertain calibration in realistic prevalence settings. Across tasks, high discrimination alone is insufficient.

physics.med-ph

EditVerse3D: High-Quality 3D Object Editing with Region-Aware Learning

Local editing of 3D objects remains a long-standing challenge. When interacting with 3D content, humans naturally tend to specify a coarse region of interest for modification rather than defining precise editing boundaries. However, previous methods rely on fully edited 2D images, precise 3D masks, or redundant pipelines, which present a gap. To bridge this gap, we propose EditVerse3D, a novel 3D editing framework that enables high-quality object editing under such coarse guidance. Our approach takes as input a 3D object to be edited, a coarse 3D bounding box indicating the target region, and a reference 2D image describing the desired modification. It produces a coherent, high-fidelity edited 3D object. To facilitate this editing, we introduce a novel region-aware adaptive loss that emphasizes hard-to-learn regions and balances the objective between target and preserved areas. Complementing our loss function, we enhance model robustness and generalization through targeted data augmentations, such as training with scaled 3D masks and filtering out unrealistic editing pairs. We construct a large-scale 3D editing dataset derived from parts information. Extensive experiments demonstrate that EditVerse3D achieves superior visual quality and quantitative performance compared to existing 3D editing approaches. Please visit our project page at https://editverse3d.github.io.

cs.CV

Detail++: Training-Free Detail Enhancer for T2I Diffusion Models

Recent advances in text-to-image (T2I) generation have led to impressive visual results. However, these models still face significant challenges when handling complex prompt, particularly those involving multiple subjects with distinct attributes. Inspired by the human drawing process, which first outlines the composition and then incrementally adds details, we propose Detail++, a training-free framework that introduces a novel Progressive Detail Injection (PDI) strategy to address this limitation. Specifically, we decompose a complex prompt into a sequence of simplified sub-prompts, guiding the generation process in stages. This staged generation leverages the inherent layout-controlling capacity of self-attention to first ensure global composition, followed by precise refinement. To achieve accurate binding between attributes and corresponding subjects, we exploit cross-attention mechanisms and further introduce a Centroid Alignment Loss at test time to reduce binding noise and enhance attribute consistency. Extensive experiments on T2I-CompBench and a newly constructed style composition benchmark demonstrate that Detail++ significantly outperforms existing methods, particularly in scenarios involving multiple objects and complex stylistic conditions.

cs.CV

BrainDINO: A Brain MRI Foundation Model for Generalizable Clinical Representation Learning

Brain MRI underpins a wide range of neuroscientific and clinical applications, yet most learning-based methods remain task-specific and require substantial labeled data. Here we show that a single self-supervised representation can generalize across heterogeneous brain MRI endpoints. We trained BrainDINO, a self-distilled foundation model, on approximately 6.6 million unlabeled axial slices from 20 datasets encompassing broad variation in population, disease, and acquisition setting. Using a frozen encoder with lightweight task heads, BrainDINO supported transfer across tumor segmentation, neurodegenerative and neurodevelopmental conditions classification, brain age estimation, post-stroke temporal prediction, molecular status prediction, MRI sequence classification, and survival modeling. Across tasks and supervision regimes, BrainDINO consistently equaled or exceeded natural-image and MRI-specific self-supervised baselines, with particularly strong advantages under label scarcity. Representation analyses further showed anatomically organized and pathology-sensitive feature structure in the absence of task-specific supervision. Our findings indicate that large-scale slice-wise self-supervised learning can yield a unified brain MRI representation that supports diverse neuroimaging tasks without volumetric pretraining or full-network fine-tuning, establishing a scalable foundation for robust and data-efficient brain imaging analysis. Code is available at https://github.com/mclwu22/BrainDINO

cs.LG

A Digital Twin Framework for Adaptive Treatment Planning in Radiotherapy

The development of a digital twin (DT) framework for fast online adaptive proton therapy planning in prostate stereotactic body radiation therapy (SBRT) with dominant intraprostatic lesion (DIL) boost represents a significant advancement in personalized radiotherapy. This framework integrates deep learning-based multi-atlas deformable image registration, daily patient anatomy updates via cone-beam CT (CBCT), and knowledge-based plan quality evaluation using the ProKnow scoring system to achieve clinical-equivalent plan quality with substantially reduced reoptimization times compared to traditional clinical workflows. Drawing on a database of 43 prior prostate SBRT cases, the DT framework predicts interfractional anatomical variations for new patients and pre-generates multiple probabilistic treatment plans. Upon acquiring daily CBCT, it enables rapid plan reoptimization, achieving an average reoptimization time of 5.5 [2.8, 8.2] minutes, compared to 19.8 [7.9, 31.7] minutes for clinical plans. The DT-based plans yielded a plan quality score of 157.2 [151.6, 162.8], surpassing or matching clinical plans, with superior dose coverage for the DIL (V100: 99.5%) and clinical target volume (CTV V100: 99.8%). Additionally, the framework minimized doses to organs at risk (OARs), achieving bladder V20.8Gy of 11.4 [7.2, 15.6] cc, rectum V23Gy of 0.7 [0.3, 1.1] cc, and urethra D10 of 90.9% [88.6%, 93.2%], aligning with clinical standards. By addressing interfractional variations efficiently, the DT framework enhances treatment precision, reduces OAR toxicity, and supports real-time adaptive radiotherapy. This transformative approach not only streamlines the planning process but also improves clinical outcomes, offering a scalable solution for prostate SBRT with DIL boost and paving the way for broader applications in adaptive proton therapy.

physics.med-ph

Testing Cosmic Distance Duality Relation and Transparency with DESI DR2

The Cosmic Distance Duality Relation (CDDR) is a fundamental principle of standard cosmology, linking luminosity (LD) and angular diameter distances (ADD). This work investigates the validity of the CDDR and cosmic transparency by combining the latest Baryon Acoustic Oscillations (BAO) data from DESI DR2, Type Ia Supernovae from Pantheon+, and cosmic chronometers. To address the redshift mismatch between datasets, two distinct reconstruction techniques are employed: Gaussian Process Regression (GPR) and the Free-Knots Method (FKM). The analysis performs null tests on the CDDR under different cosmological priors, finding that the null hypothesis holds and the CDDR is valid within statistical uncertainties. Although mild deviations are observed from the local distance ladder prior, internal consistency calibration indicates that these discrepancies and the Hubble tension may share a common origin, possibly related to systematic effects or new physics. Using multiple phenomenological parameterizations, the deviation parameter is also found to be statistically consistent with zero (e.g., $η_1 = 0.023 \pm 0.027$ for the linear model under Planck priors). Furthermore, the study finds no statistically significant evidence for cosmic opacity. The average of the opacity derivative is compatible with zero ($\langle dτ/dz \rangle = 0.0409 \pm 0.1024$ for GPR and $0.0730 \pm 0.1607$ for FKM). Based on these null results, stringent constraints are placed on the parameter space of Axion-Like Particles (ALPs) and Mini-Charged Particles (MCPs).

astro-ph.CO

Reconstructing Barrow Holographic Dark Energy in $f(Q,T)$ Gravity and Cosmic Constraint

In this work, we reconstruct the cosmological evolution of Barrow Holographic Dark Energy (BHDE) within the framework of modified gravity $f(Q,T)$. Working in the coincident gauge, we incorporate the holographic principle into non-metric gravity with non-minimal matter coupling. To address the dynamical complexity, we adopt a reconstruction approach, deriving the matter density evolution from the modified field equations rather than imposing a conserved fluid a priori. We perform parameter estimation using the latest observational data, including Type Ia supernovae, BAO, and direct Hubble parameter measurements. Our results show that the model provides a theoretical framework to describe late-time cosmic evolution and the universe's accelerated expansion. Despite the additional complexity introduced, the model offers an alternative approach for investigating dark energy within modified gravity theories.

astro-ph.CO