Search for neutrinoless quadruple beta decay of $^{136}$Xe in PandaX-4T detector

The observation of neutrinoless quadruple beta decay (0$\nu$4$\beta$) in the absence of neutrinoless double beta decay (0$\nu$2$\beta$) has been argued to provide a strong indication that neutrinos are Dirac particles. We report a search for 0$\nu$4$\beta$ decay of $^{136}\text{Xe}$ using a total $^{136}\text{Xe}$ exposure of 148.4 kg$\cdot$yr, collected during the commissioning and the first science runs of the PandaX-4T experiment. No significant excess of events over the background is observed. A lower limit on the 0$\nu$4$\beta$ decay half-life of $^{136}\text{Xe}$ is set at 6.01 x $10^{24}$ yr at the 90% confidence level. This result establishes the most stringent constraint on this process in xenon, demonstrating the unique capability of the PandaX-4T detector in probing lepton number violation and shedding light on the fundamental nature of neutrinos.

nucl-ex

Measurement of solar $pp$ neutrino flux with the new PandaX-4T data

We report a new measurement of the solar proton--proton ($pp$) neutrino flux via neutrino--electron elastic scattering using the PandaX-4T Run 2 data set collected between 2024 and 2026, corresponding to an exposure of 1.9 tonne$\cdot$yr. Before Run 2 data taking, the detector underwent a series of upgrades to improve its response and background conditions. Time variations of radioactive noble-gas impurities are constrained using the physics data themselves, complemented by measurements from the gas-assay system. The analysis introduced improvements in the data processing chain, detector response characterization, and background models. A blind spectral analysis was then performed on the electronic-recoil data across a wide energy range from 20 to 1000 keV. In combination with the Run 0 data published earlier, the fitted $pp$ flux is $(8.5 \pm 3.5)\times 10^{10}$ $\mathrm{cm^{-2}s^{-1}}$, consistent with the prediction of the Standard Solar Model. With a statistical significance of $2.2\sigma$ above background, this marks the first positive indication of solar $pp$ neutrino--electron scattering below an electronic-recoil energy of 165 keV.

hep-ex

Design, construction, and testing of the PandaX-xT cryogenics system

The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of liquid xenon. A new cryogenics system of the PandaX-xT is described in this paper. It is developed to handle large mass of liquid xenon efficiently and safely, including two cooling towers for normal operation and one liquid-nitrogen coil for emergency case. Each cooling tower equipped with an AL600 Gifford-McMahon cryocooler features a 1300 W heater, specifically designed to maintain the cold finger's temperature at the desired setpoint. The performance of the cooling tower and the coil has been tested. The cryogenics system with two cooling towers has achieved about 1900~W cooling power at 178~K. The liquid nitrogen coil provides emergency cooling power of more than 1500~W at liquid xenon temperature. For the prototype of a 1-tonne liquid xenon detector, the fluctuation of xenon saturated vapor pressure remains below 1 kPa over one month, while the pressure is around 210~kPa.

physics.ins-det

The throttling refrigeration system for the large cooling power recovery of the PandaX-xT cryogenic distillation system for radon removal

In order to solve the continuous large cooling power supply problem (20 kW) for the radon-removal cryogenic distillation system, which operates at high liquid ffow rate of 856 kg/h (5 LPM) for the dark matter detector PandaX-xT of the next-generation, a throttling refrigeration system based on carbon tetraffuoride (R14) refrigerant for cooling power recovery is designed and developed. According to this system, the cooling power of the liquid xenon in the reboiler of 178K could be transferred to the product xenon cryostat to liquefy the gaseous product xenon by the R14 circulation, thus the liqueffed xenon could return to the detector with the same condition of which extracted from the detector to form a stable cooling cycle and prevent the instability of the detector. A research and development experiment is implemented to validate the feasibility of this large cooling recovery system, using the ethanol to simulate the liquid xenon. Experimental results show that the cooling power recovery of this system could achieve 17 kW with the efffciency of 76.5%, and the R14 ffow rate is 0.16 kg/s. This study realizes the online radon removal distillation with large ffow rate while eliminating the dependence of liquid nitrogen or cryocoolers, which means saving 2414 m3 liquid nitrogen per year or the power consumption of 230 kW. Furthermore, process simulation and optimization of the throttling refrigeration cycle is studied using Aspen Hysys to reveal the inffuences of the key parameters to the system, and the deviation between the simulation and experimental results is < 2.52%.

physics.ins-det

Precise $^{136}$Xe Double Beta Decay Measurement in PandaX-4T with Implications on the Nuclear Matrix Elements and Majorons

The continuous spectrum of double beta decay ($\beta\beta$) provides a sensitive probe to test the predictions of the standard model and to search for signatures of new physics beyond it. We present a comprehensive analysis of the $^{136}$Xe $\beta\beta$ spectrum utilizing $39.1 \pm 0.7~\textrm{kg}\cdot\textrm{yr}$ of $^{136}$Xe exposure from the PandaX-4T experiment. The analysis yields the most precise measurement to date of the $^{136}$Xe two-neutrino double beta decay ($2\nu\beta\beta$) half-life, $(2.14 \pm 0.05) \times 10^{21}$ years, the uncertainty of which is reduced by a factor of 2 compared to our previous result. We measure the parameter $\xi_{31}^{2\nu}$, defined as the ratio between the subleading and leading components of the $^{136}$Xe $2\nu\beta\beta$ nuclear matrix element, to be $0.59^{+0.41}_{-0.38}$, which is consistent with theoretical predictions. We also search for Majoron-emitting modes of $^{136}$Xe $\beta\beta$, establishing the most stringent limit for the spectral index $n=7$.

nucl-ex

GPS-Synchronized Monitoring of Core-collapse Supernova Bursts with PandaX-4T via Coherent Elastic Neutrino Nuclear Scattering

The landmark detection of neutrinos from SN1987A marked the dawn of neutrino astrophysics. The neutrino burst provided essential insights into fundamental properties of neutrinos, and served as key probes of stellar evolution and supernova dynamics. The recent advancement in coherent elastic neutrino-nucleus scattering enables the detection of core-collapse supernova burst neutrinos using tonne-scale liquid xenon detectors originally designed for dark matter direct detection. Leveraging this capability, we developed and deployed an online supernova monitoring system for the PandaX-4T experiment. This system features a GPS module with millisecond-level timing precision, a low false-alarm rate, and high sensitivity to galactic core-collapse supernova explosion events. The methodology is robust, directly scalable, and planned for implementation in the next-generation PandaX-20T experiment.

hep-ex

Probing scalar-neutrino and scalar-dark-matter interactions with PandaX-4T

Scalar-mediated interactions may exist among neutrinos, dark matter particles, or between the two. Double $\beta$-decay experiments provide a powerful tool to probe such exotic interactions. Using $^{136}$Xe double $\beta$-decay data from PandaX-4T, we perform the first direct spectral search in the energy range of 20 to 2800~keV, setting the most stringent limits to date on scalar-mediated neutrino self-interactions for mediator masses below 2~MeV$/c^2$. These results place significant constraints on models invoking such interactions to alleviate the Hubble Tension. Assuming the same scalar also mediates dark matter self-interactions, constraints on the dark matter-scalar interactions can be placed in conjunction with cosmological constraints.

hep-ex

Tritiated methane reduction in the PandaX-4T experiment via purge and cryogenic distillation processes

Tritium from tritiated methane (CH$_3$T) calibration is a significant impurity that restricts the sensitivity of the PandaX-4T dark matter detection experiment in the low-energy region. The CH$_3$T removal is essential for PandaX-4T and other liquid xenon dark matter direct detection experiments, as CH$_3$T serves as a critical component for low-energy calibration. To eliminate CH$_3$T, the xenon in the detector is suitably recuperated, leaving 1.8 bar of xenon gas inside, and the detector is flushed with heated xenon gas. Concurrently, leveraging the lower boiling point of methane relative to xenon, the PandaX-4T cryogenic distillation system is effectively utilized to extract CH$_3$T from xenon after optimizing the operational parameters. Following the commissioning run, 5.7 tons of xenon are purified via the distillation method. Recent data indicate that the CH$_3$T concentration reduces from $3.6\times10^{-24}$ mol/mol to $5.9\times10^{-25}$ mol/mol, demonstrating that gas purging and distillation are effective in removing CH$_3$T, even at concentrations on the order of $10^{-24}$ mol/mol.

physics.ins-det

Tomographic beta-gamma spectroscopy of nuclear beta decay

Nuclear $\beta$ decay, a sensitive probe of nuclear structure and weak interactions, has become a precision test bed for physics beyond the Standard Model, driven by recent advances in spectrometric techniques. Here we introduce tomographic $\beta$-$\gamma$ spectroscopy (TBGS) of nuclear $\beta$ decay, a method that detects the energies of $\beta$, $\gamma$, and internal conversion electrons while simultaneously reconstructing the energy deposition vertices. Using the PandaX-4T detector operated as a TBGS, we obtain a precise and unbiased decay scheme of $^{214}$Pb, a key background isotope in searches for dark matter and Majorana neutrinos. For the first time, transitions of $^{214}$Pb to both the ground and excited states of $^{214}$Bi are measured concurrently, revealing discrepancies in branching ratios of up to 4.7$\sigma$ relative to previous evaluations. Combined with state-of-the-art theoretical spectral-shape calculations, these results establish a new benchmark for background modelling in rare-event searches and highlight the potential of TBGS as a versatile tool for fundamental physics and nuclear applications.

nucl-ex

Precise Measurement of $^{216}$Po Half-life with Exact Parent-daughter Pairing in PandaX-4T

We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes successive $\alpha$ decays, first to $^{216}\rm Po$ and then to $^{212}\rm Pb$. PandaX-4T detector measures the 5-dimensional (5D) information of each decay, including time, energy, and 3-dimensional positions. Therefore, we can identify the $^{220}\rm Rn $ and $^{216}\rm Po$ decay events and pair them exactly to extract the lifetime of each $^{216}\rm Po$. With a large data set and high-precision $^{220}\rm $Rn-$^{216}\rm $Po pairing technique, we measure the $^{216}\rm Po$ half-life to be $143.7\pm0.5$ ms, which is the most precise result to date and agrees with previously published values. The leading precision of this measurement demonstrates the power of 5D calorimeter and the potential of exact parent-daughter pairing in the xenon TPC.

nucl-ex

Search for Light Dark Matter with 259-day data in PandaX-4T

We present a search for light dark matter particles through their interactions with atomic electrons and nucleons, utilizing PandaX-4T data with an effective exposure of 1.04 tonne$\cdot$year for ionization-only data and 1.20 tonne$\cdot$year for paired data. Our analysis focuses on the energy range (efficiency$>$0.01) of approximately 0.33 to 3 keV for nuclear recoils, and from 0.04 to 0.39 keV for electronic recoils. We establish the most stringent constraints on spin-independent dark matter-nucleon interactions within a mass range of 2.5 to 5.0 GeV/$c^2$, spin-dependent neutron-only interactions within 2.0 to 5.3 GeV/$c^2$, and spin-dependent proton-only interactions within 2.0 to 3.8 GeV/$c^2$. Their corresponding limits at 3\,GeV/$c^2$ are $1.1 \times 10^{-43}$, $1.6 \times 10^{-38}$, and $5.6 \times 10^{-37}$\,cm$^2$, respectively. Additionally, our results improve the upper limits on the dark matter-electron scattering cross-section by a factor of 1.5 and 9.3 for heavy and light mediator scenarios respectively within 50 MeV/$c^2$ to 10 GeV/$c^2$, compared with previous best results.

hep-ex

Position reconstruction and surface background model for the PandaX-4T detector

We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction algorithms: template matching (TM) method and photon acceptance function (PAF) method. Both methods determine the horizontal position of events based on the light pattern of secondary scintillation collected by the light sensors. After a comprehensive evaluation of resolution, uniformity, and robustness, the PAF method was selected for position reconstruction, while the TM method was employed for verification. The PAF method achieves a bulk event resolution of 1.0 mm and a surface event resolution of 4.4 mm for a typical $S2$ signal with a bottom charge of 1500 PE (about 14 keV). The uniformity is around 20\%. Robustness studies reveal average deviations of 5.1 mm and 8.8 mm for the commissioning run (Run0) and the first science run (Run1), respectively, due to the deactivation of certain PMTs. A data-driven surface background model is developed based on the PAF method. The surface background is estimated to be $0.09 \pm 0.06$ events for Run0 (0.54 tonne$\cdot$year) and $0.17 \pm 0.11$ events for Run1 (1.00 tonne$\cdot$year).

physics.ins-det

Search for Double Beta Decay of $^{136}$Xe to the $0^+_1$ Excited State of $^{136}$Ba with PandaX-4T

We perform a search of double beta decay of $^{136}$Xe to the excited state, $0^+_1$, of $^{136}$Ba (2$\nu \beta \beta$-0$_1^+$), using the dual-phase xenon detector of PandaX-4T with the first 94.9-day commissioning data. The multi-site events are reconstructed up to the MeV energy scale, which helps to improve the background model significantly. The background contribution from the stainless steel platform outside PandaX-4T cryostat is evaluated for the first time. No significant evidence for 2$\nu \beta \beta$-$0_1^+$ is observed, resulting in a lower limit on half-life of $7.5 \times 10^{22}$ yr at the 90% confidence level. This is the first experimental limit on such a rare decay in a natural xenon-based detector.

nucl-ex

Search for Solar Boosted Dark Matter Particles at the PandaX-4T Experiment

We present a novel constraint on light dark matter utilizing $1.54$ tonne$\cdot$year of data acquired from the PandaX-4T dual-phase xenon time projection chamber. This constraint is derived through detecting electronic recoil signals resulting from the interaction with solar-enhanced dark matter flux. Low-mass dark matter particles, lighter than a few MeV/$c^2$, can scatter with the thermal electrons in the Sun. Consequently, with higher kinetic energy, the boosted dark matter component becomes detectable via contact scattering with xenon electrons, resulting in a few keV energy deposition that exceeds the threshold of PandaX-4T. We calculate the expected recoil energy in PandaX-4T considering the Sun's acceleration and the detection capabilities of the xenon detector. The first experimental search results using the xenon detector yield the most stringent cross-section of $3.51 \times 10^{-39}~\mathrm{cm}^2$ at $0.08~\mathrm{MeV}$/$c^2$ for a solar boosted dark matter mass ranging from $0.02$ to $10~ \mathrm{MeV}$/$c^2$, achieving a 23 fold improvement compared with earlier experimental studies.

hep-ex

Searching for Neutrinoless Double-Beta Decay of $^{136}$Xe with PandaX-4T

We report the search for neutrinoless double-beta decay of $^{136}$Xe from the PandaX-4T experiment with a 3.7-tonne natural xenon target. The data reconstruction and the background modeling are optimized in the MeV energy region. A blind analysis is performed with data from the commissioning run and the first science run. No significant excess of signal over the background is observed. A lower limit on the half-life of $^{136}$Xe neutrinoless double-beta decay is established to be $2.1 \times 10^{24}$~yr at the 90\% confidence level, with a $^{136}$Xe exposure of 44.6~kg$\cdot$year. Our result represents the most stringent constraint from a natural xenon detector to date.

nucl-ex

Measurement of two-neutrino double electron capture half-life of $^{124}$Xe with PandaX-4T

Detailed studies of two-neutrino double electron capture (2$\nu$DEC) is a crucial step towards searching for the neutrino-less mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2$\nu$DEC process in $^{124}$Xe, utilizing a total exposure of 1.73 tonne$\cdot$year from the commissioning run and the first science run of the PandaX-4T experiment. A time-dependent background model in the $\mathcal{O}$(10 keV) energy is constructed for the first time in PandaX-4T data. With an unbinned maximum likelihood fit, we determine the half-life of the 2$\nu$DEC process to be $(1.03\pm0.15_{\rm stat}\pm0.08_{\rm sys})\times 10^{22}$$\,$yr. Furthermore, we have evaluated the branching ratio for both electrons captured from the $K$ shell ($KK$) to be $(65\pm5)\%$, which aligns with the $^{124}$Xe nuclear model calculations within 1.8$\,$$\sigma$.

nucl-ex

Search for MeV-Scale Axionlike Particles and Dark Photons with PandaX-4T

Axionlike particles (ALPs) and dark photons (DPs) are viable dark matter particle candidates. We have searched for possible ALP/DP signals in the PandaX-4T liquid xenon detector using 440 kg$\cdot$yr of data. A binned likelihood fit is constructed to search for possible mono-energetic peaks induced by the absorption processes between ALPs/DPs and atomic electrons of xenon. A detailed temporal model of decays associated with xenon isotopes is introduced to constrain the number of background events. No signal excess over background expectations is observed, and we have established the most stringent exclusion limits for most ALP/DP masses across the range of 150 keV/$c^2$ to 1 MeV/$c^2$. The improvement is particularly significant within the mass range of \text{150-400}~keV/$c^2$, with the average factor of 3.5 compared to previous results.

hep-ex

Exploring New Physics with PandaX-4T Low Energy Electronic Recoil Data

New particles beyond the standard model of particle physics, such as axions, can be effectively searched through their interactions with electrons. We use the large liquid xenon detector PandaX-4T to search for novel electronic recoil signals induced by solar axions, neutrinos with anomalous magnetic moment, axionlike particles, dark photons, and light fermionic dark matter. A detailed background model is established using the latest datasets with 1.54 $\rm ton \cdot yr$ exposure. No significant excess above the background has been observed, and we have obtained competitive constraints for axion couplings, neutrino magnetic moment, and fermionic dark matter interactions.

hep-ex